1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2642004/6HOME THEATER RECEIVERMB26420046RX-F10STABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFI
2、C SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 ADJUS
3、TMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-185 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、1-19Area suffixJ - U.S.A.C - Canada1-2 (No.MB264)SPECIFICATION*1: Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs & specifications are subject to change without notice.AmplifierOutput Power At stereo op-erationFront channels 100 W per c
5、hannel, min. RMS, both channels driven into 6 at 40 Hz to 20 kHz with no more than 0.8% total harmonic distortion.At surround operationFront channels 100 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion.Center channel 100 W, min. RMS, driven into 6 at
6、1 kHz, with no more than 0.8% total harmonic distortion.Surround channels 100 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround back channel 100 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.AudioAudio I
7、nput Sensitivity/Imped-anceDVR/DVD (DVD MULTI), VCR, DBS, TV:330 mV/47 kAudio Input (DIG-ITAL IN)*1Coaxial DIGITAL IN 1(DVR/DVD):0.5 V(p-p)/75 Optical DIGITAL IN 2(DBS), 3(VCR): -21 dBm to -15 dBm (660 nm 30 nm)Audio Output Level DVR, VCR, MONITOR OUT:330 mVSignal-to-Noise Ratio (66 IHF/DIN)80 dB/62
8、 dBFrequency Response (6 ) 20 Hz to 20 kHz (1 dB)Bass Boost +4 dB 1 dB at 100 HzEqualization (at DSP operation) Center frequency:63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range:8 dBVideoVideo Input Sensitivity/Imped-anceComposite video:DVR/DVD, VCR, DBS 1 V(p-p)/75 S-video:DVR/DVD, VCR, DBS Y (lumi
9、nance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCR Y (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Video Output Level/Impedance Composite video:DVR, VCR, MONITOR OUT1 V(p-p)/75 S-video:DVR, VCR, MONITOR OUT Y (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75
10、 Component:MONITOR OUT Y (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Synchronization NegativeFM tuner (IHF)Tuning Range 87.5 MHz to 108.0 MHzUsable Sensitivity Monaura:12.8 dBf (1.2 V/75 )50 dB Quieting Sensitivity Monaural:16.0 dBf (1.7 V/75 )Stereo:37.5 dBf (20.5 V/75 )Stereo Separation at REC OU
11、T 35 dB at 1 kHzAM tunerTuning Range 530 kHz to 1 710 kHzGeneralPower Requirements AC 120 V , 60 HzPower Consumption 120 W/160 VA (at operation) 2 W (in standby mode)Dimensions (W H D) 435 mm 70 mm 329.5 mm (17 3/16 inches 2 13/16 inches 13 inches)Mass 6.3 kg (13.9 lbs)(No.MB264)1-3SECTION 1PRECAUTI
12、ON1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be ident
13、ical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers w
14、arranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can
15、 theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identi
16、fied by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The l
17、eads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should
18、 be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,head
19、phone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed met
20、al parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt o
21、r more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particu
22、larly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipm
23、ent has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical compon
24、ents are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts