1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB3302004/10MICRO COMPONENT SYSTEMMB330200410UX-HB4TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECI
2、FIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84 ADJ
3、USTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-205 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. 1-23CA-UXHB4 SP-UXHB4SP-UXHB4Area suffixB - U.K.1-2 (No.MB330)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier Section Output Power 15 W per channel, min. RMS, driven into 4 at 1 kHz with no morethan 10% total harmonic distortion. (IEC268-3)Audio input sensitiv
5、ity/Impedance (at 1 kHz) AUX:500 mV/50 kSpeakers Impedance 4 - 16 Tuner DAB tuning range Band lll 174.928 MHz - 239.200 MHzFM tuning range 87.50 MHz - 108.00 MHzAM (MW) tuning range 522 kHz - 1 629 kHzCD player Dynamic range 85 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableCassette deck F
6、requency response Normal (type I):100 Hz-10 000 HzWow and flutter 0.35% (WRMS)General Power requirement AC 230 V , 50 HzPower consumption 40 W (at operation) 2 W (on standby)Dimensions (W/H/D) (approx.) 152 mm 233 mm 297 mmMass (approx.) 4.0 kgSpeaker Section Type Full range, bass-reflex typeSpeaker
7、s 10 cm cone 1Power handling capacity 15 WImpedance 4 Frequency range 100 Hz-15 kHzDimensions (W/H/D) (approx.) 147 mm 233 mm 189 mmMass (approx.) 1.9 kg each(No.MB330)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and component
8、s specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Altera
9、tions of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resultin
10、g therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltag
11、e, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substituterepl
12、acement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fro
13、mlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage
14、shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do
15、 notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known goo
16、d earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor b
17、etween an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor.
18、Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility
19、of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3
20、 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagr
21、ams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J
22、 and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB330)1.5 Safety Precautions (U.K only)(1) This design of this product contains special hardware and many circuits and components specially
23、 for safety purposes. For con-tinued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replace-ment parts must be identical to those used in the original circuits.(2) Any unauthorised design alterations or additions will void the manufactu
24、rers guarantee; furthermore the manufacturer cannotaccept responsibility for personal injury or property damage resulting therefrom.(3) Essential safety critical components are identified by ( ) on the Parts List and by shading on the schematics, and must neverbe replaced by parts other than those l
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXHB4ServiceManual 电路 原理图