Jvc-NXF-40-Service-Manual电路原理图.pdf
《Jvc-NXF-40-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-NXF-40-Service-Manual电路原理图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2009 Victor Company of Japan, LimitedNo.MB6952009/4COMPACT COMPONENT SYSTEMMB69520094SERVICE MANUALNX-F30B, NX-F30E, NX-F30EN, NX-F40B, NX-F40E, NX-F40ENCOPYRIGHT 2009 Victor Company of Japan, LimitedLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219
2、 Centigrade)Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRU
3、CTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 ADJUSTMENT . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15CA-NXF40SP-N
5、XF40FCA-NXF30SP-NXF30FSP-NXF40FSP-NXF30FSP-NXF30W1-2 (No.MB695)SPECIFICATIONMain unit (CA-NXF40/CA-NXF30)Designs and specifications are subject to change without notice.TunerFM frequency 87.50 MHz - 108.00 MHzTerminal (front of the main unit)USB digital input terminal 1Audio output headphone termina
6、l 1 Impedance 16 - 1 kTerminal (rear of the main unit)Audio output speaker terminals 1Left/right speakers Output power 220 W (55 W 4) at 3 (1 kHz/10% THD)Impedance 3 - 16 Subwoofer Output power 180 W at 6 (100 Hz/10% THD)Impedance 6 - 16 Optical digital input terminal 1 -23 dBm to -15 dBmOptical dig
7、ital output terminal 1 -23 dBm to -15 dBmComponent video output terminals 1 Y 1.0 Vp-p, 75 terminatedPB 0.7 Vp-p, 75 terminatedPR 0.7 Vp-p, 75 terminatedComposite video output terminal 1 1.0 Vp-p, 75 terminatedAudio input terminals 1 500 mV/47 kHDMI monitor output terminal 1FM antenna terminal 1USBC
8、ompatible with USB 2.0 Full-SpeedCompatible device USB mass storage class deviceCompatible file system FAT16, FAT32Output power DC 5 V = 500 mAHDMIOutput power DC 5 V = 55 mAGeneralPower source AC 230 V , 50 HzPower consumption (in operation) 100 WPower consumption (on standby) 1 W or lessDimensions
9、 (W H D) including projecting parts 312 mm 95 mm 312.3 mmMass 3.5 kgSpeakers (SP-NXF40F/SP-NXF30F)Type 1-way bass reflex typeMagnetically shielded typeSpeaker driver Front ch 5.5 cm coneSurround ch 5.5 cm conePower handling capacity Front ch 55 WSurround ch 55 WImpedance 3 Frequency range 80 Hz - 20
10、 kHzSound pressure level 77 dB/W/mDimensions (W H D) including projection parts 88 mm 203 mm 127 mmSubwoofer (SP-NXF30W)Type Bass reflex typeSpeaker driver 16 cm conePower handling capacity 180 WImpedance 6 Frequency range 30 Hz - 200 HzSound pressure level 76 dB/W/mDimensions (W H D) 300 mm 301 mm
11、303 mmMass 8.2 kg(No.MB695)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by t
12、hemanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design altera
13、tions or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are o
14、ften not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Elect
15、rical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual ma
16、y create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is requ
17、ired, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna te
18、rminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, m
19、easure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outl
20、et. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resisto
21、r connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds t
22、o 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.
23、(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-f
24、orming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are critic