Jvc-TUDB-1-SU-Service-Manual电路原理图.pdf
《Jvc-TUDB-1-SU-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-TUDB-1-SU-Service-Manual电路原理图.pdf(25页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.YA2242004/11DIGITAL TERRESTRIAL SET TOP BOXYA224200411TU-DB1SUTABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . 1-64 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-95 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . 1-10MENUBACKPOKTV/DTV1TV324 657 980 AVTVTOP MENUSTBWIDE GUIDESUB TITLE1-2 (No.YA224)SPECIFICATIONDesign & specifications are subject to change without notice.Items ContentsDimensions ( W H D ) 28.0cm 4.0cm 18.5cmMass 1.3kgBroadcasting System DVB-T 2k & 8kRF System PALVideo System PALAu
5、dio System MPEG Layer I & II , 32kHz / 44.1kHz / 48kHz , Single / Dual channels , Stereo & joint stereoTeletext System Digital TeletextChannel Memory Number 200chChannel Coverage 47.0MHz to 858MHzPower Requirements DC6V, AC adaptor : AC100V to AC240V, 50Hz / 60HzAntenna Input 75 unbalanced, PAL type
6、 1 (5V DC active antenna supply)TV Output 75 unbalanced, PAL type 1 (Loop through)TV(SCART-1)Terminal(Input/Output)Video 1V (p-p) , 75Audio 500mV (rms) (-4dBs), 10k minRGB / Video 1V (p-p) , 75S-VideoY : 1V (p-p) positive, 75C : 0.286V (p-p) (burst signal), 75VCR(SCART-2)Terminal(Input/Output)Video
7、1V (p-p) , 75Audio 500mV (rms) (-4dBs), 10k minRGB / Video 1V (p-p) , 75S-VideoY : 1V (p-p) positive, 75C : 0.286V (p-p) (burst signal), 75Digital Audio Output SPDIF coaxial 1Remote Control Unit VE-30031949 (RM-C1890S), (AA/R06 dry battery 2)(No.YA224)1-3SECTION 1PRECAUTION1.1 SAFETY PRECAUTIONS(1)
8、The design of this product contains special hardware,many circuits and components specially for safetypurposes. For continued protection, no changes should bemade to the original design unless authorized in writing bythe manufacturer. Replacement parts must be identical tothose used in the original
9、circuits. Service should beperformed by qualified personnel only.(2) Alterations of the design or circuitry of the products shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacturer of responsibility for personal injury orprop
10、erty damage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. Thesecharacteristics are often not evident from visual inspectionnor can the protection afforded by them necessarily beobtained by using replacement components rated f
11、orhigher voltage, wattage, etc. Replacement parts whichhave these special safety characteristics are identified inthe parts list of Service manual. Electrical componentshaving such features are identified by shading on theschematics and by ( ) on the parts list in Servicemanual. The use of a substit
12、ute replacement which doesnot have the same safety characteristics as therecommended replacement part shown in the parts list ofService manual may cause shock, fire, or other hazards.(4) Dont short between the LIVE side ground andISOLATED (NEUTRAL) side ground or EARTH sideground when repairing. Som
13、e models power circuit is partly different in the GND.The difference of the GND is shown by the LIVE : ( ) sideGND, the ISOLATED (NEUTRAL) : ( ) side GND andEARTH : ( ) side GND. Dont short between the LIVE side GND and ISOLATED(NEUTRAL) side GND or EARTH side GND and nevermeasure the LIVE side GND
14、and ISOLATED (NEUTRAL)side GND or EARTH side GND at the same time with ameasuring apparatus (oscilloscope etc.). If above note willnot be kept, a fuse or any parts will be broken.(5) If any repair has been made to the chassis, it isrecommended that the B1 setting should be checked oradjusted (See AD
15、JUSTMENT OF B1 POWER SUPPLY).(6) The high voltage applied to the picture tube must conformwith that specified in Service manual. Excessive highvoltage can cause an increase in X-Ray emission, arcingand possible component damage, therefore operationunder excessive high voltage conditions should be ke
16、pt toa minimum, or should be prevented. If severe arcingoccurs, remove the AC power immediately and determinethe cause by visual inspection (incorrect installation,cracked or melted high voltage harness, poor soldering,etc.). To maintain the proper minimum level of soft X-Rayemission, components in
17、the high voltage circuitryincluding the picture tube must be the exact replacementsor alternatives approved by the manufacturer of thecomplete product.(7) Do not check high voltage by drawing an arc. Use a highvoltage meter or a high voltage probe with a VTVM.Discharge the picture tube before attemp
18、ting meterconnection, by connecting a clip lead to the ground frameand connecting the other end of the lead through a 10k2W resistor to the anode button. (8) When service is required, observe the original lead dress.Extra precaution should be given to assure correct leaddress in the high voltage cir
19、cuit area. Where a short circuithas occurred, those components that indicate evidence ofoverheating should be replaced. Always use themanufacturers replacement components.(9) Isolation Check (Safety for Electrical Shock Hazard) After re-assembling the product, always perform anisolation check on the
20、 exposed metal parts of the cabinet(antenna terminals, video/audio input and output terminals,Control knobs, metal cabinet, screw heads, earphone jack,control shafts, etc.) to be sure the product is safe to operatewithout danger of electrical shock.a) Dielectric Strength Test The isolation between t
21、he AC primary circuit and all metalparts exposed to the user, particularly any exposed metalpart having a return path to the chassis should withstand avoltage of 3000V AC (r.m.s.) for a period of one second. (. . . Withstand a voltage of 1100V AC (r.m.s.) to anappliance rated up to 120V, and 3000V A
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcTUDB1SUServiceManual 电路 原理图