1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4312005/8MICRO COMPONENT SYSTEMMB43120058UX-G5Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-155 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18CA-UXG5 SP-UXG5SP-UXG5Area suffixA - AustraliaUS - SingaporeUP - KoreaUT - TaiwanUW - Brazil,Mexico,PeruUY - ArgentinaUJ - U.S.Military1-2 (No.MB431)SPECIFICATIONDesign and specifications are subject to change
5、 without notice.Amplifier section Output Power 100 W (50 W+50 W) at 6 (10% THD)Speakers Impedance 6 - 16 Audio Input AUX 400 mV/50 kTuner section FM tuning range 87.50 MHz - 108.00 MHzAM tuning range 531 kHz - 1 710 kHz (at 9 kHz)530 kHz - 1 710 kHz (at 10 kHz)CD player section Dynamic range 85 dBSi
6、gnal-to-noise ratio 85 dBWow and flutter ImmeasurableCassette deck section Frequency response: Normal (type l) 60 Hz - 14 000 HzWow and flutter 0.15% (WRMS)General Power requirement AC 110 V - 127 V / 220 V - 240 V (adjustable with the voltage selector), 50 Hz/60 HzPower consumption 90 W (at operati
7、on)0.8 W (on standby)Dimensions (approx.) 175 mm 232 mm 412 mm (W/H/D)Mass (approx.) 6.6 kgSpeakers Type 2-way Bass reflexSpeaker units Woofer 10 cm cone 1Tweeter 4 cm cone 1Impedance 6 Dimensions (approx.) 144 mm 231 mm 201 mm (W/H/D)Mass (approx.) 2.0 kg each(No.MB431)1-3SECTION 1PRECAUTION1.1 Saf
8、ety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical toth
9、ose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty a
10、nd will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprote
11、ction afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by s
12、hading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in t
13、he products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be obser
14、ved, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jac
15、k, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts
16、of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more se