Jvc-THM-508-Service-Manual电路原理图.pdf
《Jvc-THM-508-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-THM-508-Service-Manual电路原理图.pdf(89页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2942004/7DVD DIGITAL CINEMA SYSTEMMB29420047TH-M508TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPE
2、CIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84 A
3、DJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-345 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . 1-36Area suffixUS - SingaporeUW - Brazil,Mexico,PeruUX - Saudi ArabiaUG - Turkey,South Africa,EgyptUN - Asean(SP-THM508C) (SP-THM508F)(SP-THM505S) (SP-PWM508)(XV-THM508)1-2 (No.MB294)SPECIFICATIONCenter unit (XV-THM508)*1 : This value is measured at System cord CONNECTOR for reference.*2 : Corre
5、sponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency - 32 kHz, 44.1 kHz, 48 kHz)*3 : For PAL systemSubwoofer (SP-PWM508)Satellite Speakers-Front speakers (SP-THM508F)Audio section Digital input*2 DIGITAL IN (DBS) (OPTICAL) -21 dBm to -15 dBm (660 nm E30 nm)Video s
6、ection Video System NTSC/PAL selectableHorizontal Resolution 500 linesSignal-to-Noise Ratio 64 dBVideo output level Composite 1.0 V(p-p)/75 S-video-Y 1.0 V(p-p)/75 S-video-C 0.286 V (0.3 V*3) (p-p)/75 Component-Y 1.0 V(p-p)/75 Component-PB/PR 0.7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN)C
7、omposite 1.0 V(p-p)/75 S-video-Y 1.0 V(p-p)/75 S-video-C 0.286 V (0.3 V*3) (p-p)/75 Tuner section Tuning Range FM 87.50 MHz to 108.00 MHzAM 531 kHz to 1 602 kHz (at 9 kHz intervals)530 kHz to 1 600 kHz (at 10 kHz intervals)General Power Requirements AC 110 - 240 V , 50/60 Hz (except for Australia)AC
8、 240 V , 50 Hz (for Australia only)Power Consumption 18 W (at operation) 2.0 W (in standby mode)Dimensions (W H D) 400 mm 85 mm 380 mmMass 4.3 kgAmplifier section Front/Center/Surround 140 W per channel, RMS at 4 (Center/Surround)/ 140 W per channel, RMS at 4 (Front) at 1 kHz, with 10 % total harmon
9、ic distortion.Subwoofer 300 W, RMS at 4 at 100 Hz, with 10 % total harmonic distortion.Speaker section Speaker unit 25 cm Bass-reflex, Magnetically ShieldedFrequency Range 20 Hz to 200 HzGeneral Power Requirements AC 110 V/127 V/220 - 240 V selectable with the voltage selector, 50 Hz/60 HzPower Cons
10、umption 170 W (at operation) 0 W (in standby mode)Dimensions (W H D) 256 mm 482 mm 460 mmMass 18.5 kgSpeakers Woofer 10.0 cm 2Tweeter 4.0 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 60 Hz to 20 kHzDimensions (W H D) 250 mm 1065.5 mm 310 mmMass 7.2 k
11、g(No.MB294)1-3Satellite Speakers-Surround speakers (SP-THM505S)Satellite Speakers-Center speaker (SP-THM508C)Designs & specifications are subject to change without notice.Speakers 8.0 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 80 Hz to 20 kHzDimens
12、ions (W H D) 111.5 mm 139 mm 106.5 mmMass 0.52 kgSpeakers Woofer 8.0 cm 2Tweeter 4.0 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 65 Hz to 20 kHzDimensions (W H D) 326 mm 119 mm 170 mmMass 2.5 kg1-4 (No.MB294)SECTION 1PRECAUTION1.1 Safety Precautions
13、(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the
14、 original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further
15、 relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded
16、by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the s
17、chematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are
18、 routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it sho
19、uld be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shaf
20、ts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet,
21、 particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the
22、 following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal
23、part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed an
24、d manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby appr
- 配套讲稿: