Jvc-UXG-3-Service-Manual电路原理图.pdf
《Jvc-UXG-3-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXG-3-Service-Manual电路原理图.pdf(54页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4292005/7MICRO COMPONENT SYSTEMMB42920057UX-G3, UX-G4Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-165 TROUBLESHOOTING . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19CA-UXG3 SP-UXG3SP-UXG3CA-UXG4 SP-UXG4SP-UXG4Area suffixUS - SingaporeUB - Hong KongUP - KoreaUT - TaiwanUW - Brazil,Mexico,PeruUY - ArgentinaUX-G3Area suffixUX-G4A - AustraliaUS - SingaporeUB - Hong Kon
5、gUT - TaiwanUW - Brazil,Mexico,Peru1-2 (No.MB429)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier Section Output Power 25 W per channel, min. RMS, driven into 4 at 1 kHz with no more than 10% total harmonic distortion (IEC268-3).Audio input sensitivity/Impedance
6、(at 1 kHz) AUX: 500 mV/50 kSpeakers Impedance 4 - 16 Tuner FM tuning range 50 kHz intervals 87.50 MHz-108.00 MHz100 kHz intervals 87.5 MHz-108.0 MHzAM tuning range 9 kHz intervals 531 kHz-1 710 kHz10 kHz intervals 530 kHz-1 710 kHzCD player Dynamic range 85 dBSignal-to-noise ratio 85 dBWow and flutt
7、er ImmeasurableCassette deck Wow and flutter 100 Hz - 10 000 HzWow and flutter 0.35% (WRMS)General Power requirement AC 110 V-127 V / AC 220 V-240 V (adjustable with the voltage selec-tor), 50Hz / 60HzPower consumption 52 W (at operation)3.0 W (on standby)Dimensions (W/H/D) (approx.) 152 mm 233 mm 3
8、31 mmMass (approx.) 4.7 kgSpeaker Section Type Full range, bass-reflex typeSpeakers 10 cm cone 1Power handling capacity 25 WImpedance 4 Frequency range 100 Hz - 15 kHzDimensions (W/H/D) (approx.) 152 mm 233 mm 188 mmMass (approx.) 1.8 kg each(No.MB429)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1)
9、This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the ori
10、ginal circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further rel
11、ieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by t
12、hem necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schem
13、atics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are rou
14、ted and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should
15、be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts,
16、etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, par
17、ticular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the fol
18、lowing manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXG3ServiceManual 电路 原理图