1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.No.220262003/03RX-6030VBKAUDIO/VIDEO CONTROL RECEIVER22026200302RX-6030VBKTABLE OF CONTENTS1 Important Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
2、22 Disassembly method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . 1-124 Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13Area suffixJ - U.S.A.C - CanadaTA/NEWS/INFODISPLAY MODE DIGITAL AUTO SPK ONE TO UCH OPE RATIONBASS BOOSTPRO LOGI CDSP H.PHO
4、NE AUTO MUTINGTUNED STEREO TANEWS INFO VOLUMEINPUT ATT EON RDS SLEEPCH12ANALOG LLINEAR P CMDIGITALC RS.WFR LFELS RSSSTANDBYSTANDBY/ONPHONES D IGITA LPRO LOGICSURROUNDDSPDVD MULTISPEAKERSON/OFFSUBWOOFER O UT FM MODEMEMORYON/OFFFM/AM T UNINGDVD VCR CD FM AMTAPE/CDRTV SO UNDSURROUND/DSPOFFDIMMERINPUT D
5、IGITALRX AUDIO/VIDEO CONTROL RECEIVERSETTING MULTI JOGSETADJUSTEXITINPUT ANALOGMASTER VOL UMEINPUT ATTFM/AM RESETSOURCE NAMERX-6030VBK1-2 (No.22026)SECTION 1Important Safety Precautions1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components spe
6、cially for safety purposes.For continued protection, no changes should be made to theoriginal design unless authorized in writing by the man-ufacturer. Replacement parts must be identical to thoseused in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations
7、 of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting the
8、refrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, wa
9、tt-age, etc. Replacement parts which have these special safetycharacteristics are identified in the Parts List of Service Manu-al. Electrical components having such features are iden-tified by shading on the schematics and by ( ) on theParts List in the Service Manual. The use of a substitute re-pla
10、cement which does not have the same safety character-istics as the recommended replacement parts shown in theParts List of Service Manual may create shock, fire, or oth-er hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fr
11、omlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassembling.(5) Leakage
12、shock hazard testing)After reassembling the product, always perform an isolationcheck on the exposed metal parts of the product (antennaterminals, knobs, metal cabinet, screw heads, headphonejack, control shafts, etc.) to be sure the product is safe tooperate without danger of electrical shock.Do no
13、t use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good
14、earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use an ACvoltmeter having, 1,000 ohms per volt or more sensitivity inthe following manner. Connect a 1,500 ohm 10W resistorparalleled by a 0.15 F AC-type cap
15、acitor between anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metal part,particularly any exposed metal part having a return path tothe chassis, and measure the AC voltage across the res
16、istor.Now, reverse the plug in the AC outlet and repeat eachmeasurement. Voltage measured any must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsi
17、bility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvolt
18、age.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PW
19、B diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of the same typeand rating as specified by the manufacturer. (Except the JC version)RX-6030V
20、BK(No.22026)1-31.5 Importance administering point on the safety Caution: For continued protection against risk offire, replace only with same type 6.3A/125V forF201, 2A/125V for F202 and F203.This symbol specifies type of fast operating fuse.Precaution: Pour eviter risques de feux, remplacezle fusib
21、le de surete de F201 comme le meme typeque 6.3A/125V, et 2A/125V pour F202 et F203.Ce sont des fusibles suretes qui functionnes rapide.Secondary partsPrimary partCN251D205FC221FC222FC231FC232R201RY201110111 112113 114120121122 130131B192B191B160B1592A-125V2A-125VF 203F 202FC211 FC212 6.3A-125VB104PW
22、103PW101B103B102B101B106B105PW102PW105B108B107PW104B109B110TA201TA202R1EP1RX-6030VBK1-4 (No.22026)SECTION 2Disassembly method2.1 Removing the top cover (See Fig.1)(1) From the right and left sides of the main body, remove thefour screws A attaching the top cover.(2) From the back side of the main bo
23、dy, remove the threescrews B attaching the top cover.(3) Remove the top cover in the direction of the arrow 2 whileextending the lower sections of the top cover in the direc-tion of the arrow 1.Fig.12.2 Removing the front panel assembly (See Figs.2 and 3) Prior to performing the following procedure,
24、 remove the topcover.(1) Disconnect the card wire from the connector CN402 on theaudio board. (See Fig.2)(2) Disconnect the card wire from the connector CN201 on thepower supply board. (See Fig.2)(3) Remove the tie band and wire protection board fixing thecard wire. (See Fig.2)(4) Remove the three s