Jvc-UXQD-70-W-Service-Manual电路原理图.pdf
《Jvc-UXQD-70-W-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXQD-70-W-Service-Manual电路原理图.pdf(99页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4962005/12MICRO COMPONENT MD SYSTEMMB496200512UX-QD70S,UX-QD70WLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-83 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-94 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-435 TROUBLESHOOTING . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53Area suffixUB - Hong Kong(SP-UXK30S)(SP-UXK30W)(SP-UXK30S)(SP-UXK30W)(CA-UXQD70S)(CA-UXQD70W)1-2 (No.MB496)SPECIFICATIONMD/DVD receiver (CA-UXQD70S/CA-UXQD70W)Amplifier Output power 20 W 2 (10
5、% THD/4 )Input terminals Analog AUX 1650 mV/47 k: LEVEL1260 mV/47 k: LEVEL2Digital Digital optical input 1-23 dBm to -15 dBm (Optical square terminal)(Compatible with frequency of 32 kHz, 44.1 kHz and 48 kHz)Output terminals Analog Speaker 1, 20 W/4 Impedance 4 - 16 Headphone (1), 25 mW/32 Impedance
6、 16 - 1 kDigital DVD/CD optical output 1-23 dBm to -15 dBm (Optical square terminal)Other AV COMPU LINK 2 ( 3.5)Tuner Frequency FM 87.50 MHz - 108.00 MHzAM 531 kHz - 1 710 kHz (9 kHz spacing)530 kHz - 1 710 kHz (10 kHz spacing)DVD player Playable discs DVD VIDEO, DVD AUDIO, CD, VCD, SVCD, CD-R/CDRW(
7、CD, VCD, SVCD, MP3/WMA/JPEG format),DVD-R(video format, MP3/WMA/JPEG format),DVD-RW(video format, DVD VR format, MP3/WMA/JPEG format)MD recorder Audio playing system MiniDisc digital audio systemRecording system Magneto-optical overwrite systemReading system Non-contact, semiconductor laser pickupRe
8、cording/Playback time(when using an 80-minute MD)SP 80 minutesLP2 160 minutesLP4 320 minutesSampling frequency 44.1 kHzAudio compression ATRAC (Adaptive TRansformsystem Acoustic Coding)/ATRAC3 (MDLP)Cassette deck Frequency response Normal (type l) 60 Hz - 14 000 HzWow and flutter 0.15% (WRMS)General
9、 Power source AC 220 V , 50 HzPower consumption 55 W (at operation)1.1 W (on standby)Dimensions 165 mm (W) 200 mm (H) 350 mm (D)Mass (approx.) 5.1 kg(No.MB496)1-3Speaker (SP-UXK30S/SP-UXK30W)Micro component MD system (UX-QD70S/UX-QD70W)U.S. and foreign patents licensed from Dolby Laboratories.Design
10、 and specification are subject to change without notice.System 3-way bass reflex typeMagnetically shielded typeSpeakers Woofer 10 cm cone speaker 1Midrange 4 cm cone speaker 1Tweeter 1.5 cm dome speaker 1Power handling capacity 20 WImpedance 4 Frequency range 56 Hz - 40 kHzSound pressure level 85 dB
11、/WmDimensions 135 mm (W) 200.5 mm (H) 213.5 mm (D)Mass (approx.) 2.1 kg (1 unit)Dimensions 435 mm (W) 200.5 mm (H) 350 mm (D)Mass (approx.) 9.3 kg1-4 (No.MB496)SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially
12、 for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of th
13、e design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom
14、.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age
15、, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement whi
16、ch does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts
17、, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazar
18、d testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a l
19、ine isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth gro
20、und. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an e
21、x-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, revers
22、e the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repa
23、irer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBur
24、rs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the pa