Jvc-XV-523-GD-Service-Manual电路原理图.pdf
《Jvc-XV-523-GD-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-XV-523-GD-Service-Manual电路原理图.pdf(129页珍藏版)》请在收音机爱好者资料库上搜索。
1、1. Main adjustment2. Check point for each error3. IC701 (M101C12GHA)For the above 3 items, a supplementary edition will be issued in early July.Important InformationSERVICE MANUALNo.20836XV-521BK/523GDXV-525BK/421BKXV-521BK/523GDXV-525BK/421BKContentsSafety precautionsImportance administering point
2、on the safetyDismantling and assembling the traverse unitDisassembly methodPrecautions for serviceDescription of major ICs1-21-31-41-51-151-16VICTOR COMPANY OF JAPAN, LIMITEDOPTICAL DISC BUSINESS DIV. PERSONAL & MOBILE NETWORK BUSINESS UNITAV & MULTIMEDIA COMPANY 1644, Shimotsuruma, Yamato, Kanagawa
3、 242-8514, JapanDVD PLAYERNo.20836Jun. 2000COPYRIGHT 2000 VICTOR COMPANY OF JAPAN, LTD.Printed in Japan2000 06 (S)XV-521BK/523GDXV-525BK/421BKJ U.S.AArea SuffixXV-525BK/523GDJ U.S.AC CanadaArea SuffixXV-521BKArea SuffixXV-421BKXV-521BK/523GD/525BK/421BK1-2Safety Precautions1. This design of this pro
4、duct contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Serv
5、ices should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufactur
6、e of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily b
7、e obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) o
8、n the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed
9、with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirme
10、d that they have been returned to normal, after re-assembling.5. Leakage currnet check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack,
11、control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a “Leakage Current Tester“, measure the leakage current from each exposed metal parts
12、of the cabinet , particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.)Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or mor
13、e sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to eachexposed metal part, particula
14、rly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured Any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). Warning1. This equipmen
15、t has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical componen
16、ts are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!CAUTIONBurrs formed during molding may be left over o
17、n some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.XV-521BK/523GD/525BK/421BK1-3Caution: For continued protection against risk offire, replace only with same type 1.6A/250V for F901. This symbol specifies type of fast operating fuse.Pr