1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.220232003/6HOME THEATER DVD-AUDIO/VIDEO RECEIVER2202320036RX-DV31SLTABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . 1-64 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-215 TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . 1-226 DESCRIPTION OF MAJOR ICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23Area suffixJ - U.S.A.C - CanadaDVD/SUPER VCD/VCD/CDCOMPAC TSUPER VIDE ORX-DV31 HOME THEATER DVD-AUDIO/VIDEO RECEIVER1-2 (No.22023)SP
5、ECIFICATIONAmplifier Output Power At Stereo operation Front channels 100 W per channel, min. RMS, driven into 8 , 40 Hz to 20 kHz with no more than 0.8% total harmonic distortion.At Surround operation Front channels 100 W per channel, min. RMS, driven into 8 at 1 kHz, with no more than 0.8% total ha
6、rmonic distortion.Center channel 100 W, min. RMS, driven into 8 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround channels 100 W per channel, min. RMS, driven into 8 at 1 kHz, with no more than 0.8% total harmonic distortion.Audio Audio Input Sensitivity/Impedance (1 kHz)TV, TAPE/C
7、DR, DBS, VCR 240 mV/47 kAudio Input (DIGITAL IN)* Coaxial DIGITAL 1 (DBS) 0.5 V(p-p)/75 Optical DIGITAL 2 (TV) -21 dBm to -15 dBm (660 nm 30 nm)* Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz).Signal-to-Noise Ratio (66 IHF/78 I
8、HF)TV, TAPE/CDR, DBS, VCR 87 dB/67 dBFrequency Response (8 ) TV, TAPE/CDR, DBS, VCR 20 Hz to 20 kHz (1 dB)Tone Control Bass (100 Hz) 10 dB 2 dBTreble (10 kHz) 10 dB 2 dBVideo Video Input Sensitivity/Impedance (1 kHz)Composite videoDBS IN, VCR IN 1 V(p-p)/75 S-video DBS IN, VCR IN (Y:luminance) 1 V(p
9、-p)/75(C:chrominance) 0.286 V(p-p)/75 Video Output Level/Impedance (1 kHz)Composite videoVCR OUT, MONITOR OUT 1 V(p-p)/75 S-video VCR OUT, MONITOR OUT(Y:luminance) 1 V(p-p)/75 (C:chrominance) 0.286 V(p-p)/75 Component videoDVD COMPONENT VIDEO OUT(Component-Y) 1.0 V(p-p)/75 (Component-PB/PR) 0.7 V(p-
10、p)/75 Color System NTSCHorizontal Resolution500 linesSignal-to-Noise Ratio (S/N)63 dBSynchronize NegativeFM tuner (IHF)Tuning Range 87.5 MHz to 108.0 MHzAM tuner Tuning Range 530 kHz to 1 710 kHzGeneral Power RequirementsAC 120 V , 60 HzPower Consumption200 W/255 VA (in operation)2 W (in standby mod
11、e)Dimensions (W H D)435 mm 100 mm 403.5 mm(17 3/16 in. 3 15/16 in. 15 15/16 in.)Mass 8.4 kg (18.5 lbs)(No.22023)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protecti
12、on, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldno
13、t be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in
14、the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these spe
15、cialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teris
16、tics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/or
17、sharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, alwa
18、ys perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check.
19、Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5
20、mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth gro
21、und.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each me
22、asurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are
23、 maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on
24、some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as t