Jvc-RXDP-10-RSL-Service-Manual电路原理图.pdf
《Jvc-RXDP-10-RSL-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-RXDP-10-RSL-Service-Manual电路原理图.pdf(132页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALAUDIO/VIDEO CONTROL RECEIVERNo.21025Sep. 2001COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.RX-DP10VBKRX-DP10VSLRX-DP10RSLRX-DP10VBK/RX-DP10VSLRX-DP10RSLContentsSafety precautions -1-2Importance administering point on the safety - 1-4Disassembly method -1-5Adjustment method -1-14Descripti
2、on of major ICs -1-1637STANDBY/ONSTANDBYPHONESAUDIO/VIDEO CONTROL RECEIVERDIMMERCC CONVERTERMAIN ROOMON/OFFSUB ROOMON/OFFDOORUPDOOR DOWNMASTER VOLUMERX-DP10VDIGITALDIGITALSURROUNDS-VIDEO VIDEO LAUDIORVIDEOCHANNELTV/VIDEOMUTINGDVDON/OFF ON/OFFSTANDBY/ON STANDBY/ONSTANDBYTV/CATV/DBS VCR 1ONDVD MULTI C
3、DCDRPHONOTAPE/MDAMANALOG/DIGITAL EFFECTROOM SIZESOUNDTESTLINE DIRECT CC CONVERTERSLEEP DIMMERFM MODEDSP THXSURROUNDRETURN 100+ON/OFF ON/OFFMODEWALLINPUTLIVENESSSETSETUPMENUADJUSTMENUDVDMENUEXITTEXTDISPLAY1234567/P 8910 +100TV VOL VOLUMETUNINGSTOP PAUSELIGHTFF/ REWRECPLAYDOWN UPRM-SRXDP10J REMOTE CON
4、TROLA/V CONTROL RECEIVERVCR 1 VCR 2FMVIDEOTV/DBSSUB ROOMTRANSMITLEARNMAIN ROOMSUB ROOMMAIN ROOM SUB ROOM LEARNMAIN ROOMTVCATV/DBSArea suffixB - U.K.E - Continental EuropeEN - Northern EuropeArea suffixJ - U.S.A.RX-DP10VSLArea suffixC - CanadaRX-DP10VBKRX-DP10RSLModel RF remote unit Video SEP board C
5、olorRX-DP10VSLRX-DP10VBK BlackSilverSilverRX-DP10RSLRX-DP10VBK/RX-DP10VSLRX-DP10RSL1-21. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized
6、in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made.
7、Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These ch
8、aracteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser
9、vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List
10、 of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire haz
11、ard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5. Leakage current check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check o
12、n the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly
13、into the AC outlet. Using a “Leakage Current Tester“, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check
14、 methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC volt
15、age across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage
16、 measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must
17、 be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 o
18、hms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In regard with component parts appearing on the silk-screen printed side (parts side)
19、 of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the “ “ mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the J fur
20、thermore the manufacturer cannot accept responsibility for personal injury or property damage resulting therefrom.3. Essential safety critical components are identified by ( ) on the Parts List and by shading on the schematics, and must never be replaced by parts other than those listed in the manua
21、l. Please note however that many electrical and mechanical parts in the product have special safety related characteristics. These characteristics are often not evident from visual inspection. Parts other than specified by the manufacturer may not have the same safety characteristics as the recommen
22、ded replacement parts shown in the Parts List of the Service Manual and may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp ed
23、ges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.!Burrs formed during molding may be left over on some parts of the chassi
24、s. Therefore, pay attention to such burrs in the case of preforming repair of this system.(U.K only)RX-DP10VBK/RX-DP10VSLRX-DP10RSL1-4Caution: For continued protection against risk offire, replace only with same type 1A/125V forF41, 2A/125V for F61, F62 and F42, 8A/ 125V for F21.This symbol specifie