Jvc-UXG-50-C-Service-Manual电路原理图.pdf
《Jvc-UXG-50-C-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXG-50-C-Service-Manual电路原理图.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5092006/3MICRO COMPONENT SYSTEM MB50920063UX-G50J,UX-G50CLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145 TROUBLESHOOTING . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15CA-UXG50 SP-UXG50SP-UXG501-2 (No.MB509)SPECIFICATIONDesign and specification are subject to change without notice.Amplifier section Output Power 120 W per channel, min. RMS, driven into 6 at 1 kHz w
5、ith no more than 10% total har-monic distortion.Speakers Impedance 6 - 16 Audio Input AUX Input sensitivity/Impedance:LEVEL1:150 mV/47 kLEVEL2:500 mV/47 kUSB USB Ver. 1.1Tuner section FM tuning range 87.5 MHz - 108.0 MHzAM tuning range 530 kHz - 1 710 kHzCD player section Dynamic range 85 dBSignal-t
6、o-noise ratio 85 dBWow and flutter ImmeasurableGeneral Power requirement AC 120 V , 60 HzPower consumption 155 W (at operation)20 W (at standby)0.8 W (at on standby and Display off)Dimensions (approx.) 175 mm 246 mm 415 mm (6-15/16“ 9-11/16“ 16-3/8“) (W/H/D)Mass (approx.) 7.4 kg (16.4 lbs)Speakers T
7、ype 2-way Bass reflexSpeaker units Woofer 12 cm (4“) cone 1Tweeter 4 cm (1-5/8“) cone 1Impedance 6 Dimensions (approx.) 145 mm 246 mm 212 mm (5-3/4“ 9-11/16“ 8-3/8“) (W/H/D)Mass (approx.) 2.2 kg (4.9 lbs) each(No.MB509)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product conta
8、ins special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should b
9、e per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibi
10、lity for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us
11、-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List
12、 in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps,
13、 tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been r
14、eturned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis sa
15、fe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part
16、 having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10
17、W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chass
18、is, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international s
19、afety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selec
20、tor is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the si
21、lk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the m