Jvc-THA-25-Service-Manual电路原理图.pdf
《Jvc-THA-25-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-THA-25-Service-Manual电路原理图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB1432003/12DVD DIGITAL CINEMA SYSTEMMB143200312TH-A25TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SP
2、ECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64
3、ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-125 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . 1-13Area suffixUS - SingaporeUB - Hong KongUW - Brazil,Mexico,PeruUX - Saudi ArabiaUG - Turkey,South Africa,EgyptSOUNDVOLUMESOURCESTANDBYSTANDBY/ONDVD DIGITAL CINEMA SYSTEM TH-A251-2 (No.MB143)SPECIFICATIONDesigns & specifications are subject to change without notice.Center unit (XV-THA25)Ampli
5、fier Front/Center/Rear 30 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 10% total harmonicdistortionSubwoofer 55 W, min. RMS, driven into 3 at 100 Hz, with no more than 10% total harmonic distortionAudio Audio input sensitivity/Impedance (at 1 kHz)Analog input AUX (“AUDIO IN“) 5
6、00 mV/47 kSignal-to-Noise Ratio 68 dBDigital input* DIGITAL IN (OPTICAL) -24 dBm to -14.5 dBm (700 nm 50 nm)* Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48kHz)Video Color System NTSC/PALHorizontal Resolution 480 linesOutput Level V
7、IDEO OUT (Composite) 1.0 V(p-p)/75 S-VIDEO (Y):1.0 V(p-p)/75 (C):0.286 V(p-p)/75 COMPONENT VIDEO OUT Y 1.0 V(p-p)/75 PB/PR 0.7 V(p-p)/75 Tuner Tuning Range FM 87.50 MHz - 108.00 MHzAM 531 kHz - 1 602 kHz (at 9 kHz intervals)530 kHz - 1 600 kHz (at 10 kHz intervals)Usable Sensitivity FM 8.0 dBf (0.9
8、V/75 )AM loop antenna 650 V/mGeneral Readable Discs DVD VIDEO, Video CD, Super Video CD, Audio CD, CD-R/RW (Audio CD, Video CD, SuperVideo CD, MP3, JPEG), DVD-R/RW (Video format)Power Requirements AC 110 V - 127 V/220 V - 240 V , Adjustable with the voltage selector, 50 Hz/60 HzPower Consumption 110
9、 W (at operation) 2 W (in standby mode)Dimensions (W H D) 360 mm 65 mm 404 mmMass 6.3 kgSubwoofer (SP-WA25)Speaker 15 cm Bass-reflex, magnetically shieldedPower Handling Capacity 55 WImpedance 3 (min)Frequency Range 30 Hz to 200 HzDimensions (W H D) 210 mm 382 mm 338 mmMass 6 kgSatellite Speakers (S
10、P-XTHA25)Speaker 8 cm Bass-reflex, magnetically shieldedPower Handling Capacity 30 WImpedance 6 (min)Frequency Range 80 Hz to 20 kHzDimensions (W H D) 105 mm 114 mm 116 mmMass 640 g(No.MB143)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany
11、 circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified pe
12、rsonnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or
13、propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components
14、rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The
15、use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the l
16、ike to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after rea
17、ssem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger
18、 of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to the
19、chassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.
20、15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC volta
21、ge acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is th
22、e legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setti
23、ng for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts
24、 side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulatio
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcTHA25ServiceManual 电路 原理图