Jvc-RXV-7000-UF-Service-Manual电路原理图.pdf
《Jvc-RXV-7000-UF-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-RXV-7000-UF-Service-Manual电路原理图.pdf(53页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5022006/1AUDIO/VIDEO CONTROL RECEIVERMB50220061RX-V7000UFLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145 TROUBLESHOOTING . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-151-2 (No.MB502)SPECIFICATION* : Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz)Designs and Specifications are subject to chang
5、e without notice.AmplifierOutput Power At Stereo operation Front channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion (IEC268-3/DIN).Front channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic d
6、istortion.At Surround operation Center channel 100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion.Surround channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion.Audio Audio Input Sensitivity/Impedance (
7、1 kHz) TAPE, VCR, TV SOUND/DBS, DVD:220 mV/47 kAudio Input (DIGITAL IN)* Coaxial DIGITAL 1 (DVD):0.5 V(p-p)/75 Optical DIGITAL 2 (VCR), DIGITAL 3 (TV SOUND/DBS):-21 dBm to -15 dBm (660 nm 30 nm)Recording Output Level TAPE, VCR:220 mVSignal-to-Noise Ratio (66 IHF/DIN) TAPE, VCR, TV SOUND/DBS, DVD:96
8、dB/62 dBFrequency Response (8 ) TAPE, VCR, TV SOUND/DBS, DVD:20 Hz to 50 kHz (+1 dB, -3 dB)Bass Boost +4 dB 1 dB at 100 HzEqualization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps)Video Video Input Sensitivity/Impedance Composite video:DVD, VCR, DBS 1 V(p-p)/75 S-video:DVD, VCR,
9、DBS (Y: luminance):1 V(p-p)/75 (C: chrominance, burst):0.3 V(p-p)/75 Component:DVD, VCR (Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output Level Composite video:VCR, MONITOR OUT 1 V(p-p)/75 S-video:VCR, MONITOR OUT (Y: luminance):1 V(p-p)/75 (C: chrominance, burst)0.3 V(p-p)/75 Component
10、:MONITOR OUT (Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Synchronization NegativeSignal-to-Noise Ratio 45 dBFM tuner (IHF)Tuning Range 87.50 MHz to 108.00 MHzUsable Sensitivity Monaural:12.8 dBf (1.2 V/75 )50 dB Quieting Sensitivity Monaural:16.0 dBf (1.7 V/75 )Stereo:37.5 dBf (20.5 V/75 )Ster
11、eo Separation at OUT (REC) 35 dB at 1 kHzAM tunerTuning Range 531 kHz to 1 710 kHz (at 9 kHz intervals)530 kHz to 1 710 kHz (at 10 kHz intervals)GeneralPower Requirements AC 220 V, 50 HzPower Consumption 200 W (at operation)0.9 W (in standby mode)Dimensions (W H D) 435 mm 200 mm 425 mmMass 11.4 kg(N
12、o.MB502)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Rep
13、lacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions
14、will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident fr
15、om visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components ha
16、ving such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fir
17、e, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original
18、lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, met
19、al cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage
20、currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltme
21、ter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to eac
22、h exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.)