1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB0532003/9MICRO COMPONENT SYSTEMMB05320039UX-H35TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFI
2、C SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUS
3、TMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、1-23MICRO COMPONENT SYSTEMArea SuffixA - Australia1-2 (No.MB053)SPECIFICATIONAmplifier Output Power 20 W (10 W + 10 W) at 4 (10% THD)Audio input sensitivity/Impedance (at 1 kHz) AUX 500 mV/48.75 kSpeakers/Impedance 4 Tuner FM tuning range 87.50 MHz - 108.00 MHzAM tuning range 522 kHz - 1 629 kHzCD p
5、layer Dynamic range 85 dBSignal-to-noise ratio 90 dBWow and flutter ImmeasurableCassette deck Frequency response Normal (type I) 50 Hz - 15 000 HzWow and flutter 0.15% (WRMS)Speaker Speaker units Full range 8.0 cm cone 1Impedance 4 Dimensions (approx.) 135 mm 203 mm 190 mm (W/H/D)Mass (approx.) 1.7
6、kg eachGeneral Power requirement AC IN 240 V , 50 HzDC IN 12 V, 4 APower consumption 35 W (at operation)3.0 W (on standby)Dimensions (approx.) 412 mm 208 mm 275 mm (W/H/D)Mass (approx.) 6.5 kg(No.MB053)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardw
7、are andmany circuits and components specially for safety purposes.For continued protection, no changes should be made to theoriginal design unless authorized in writing by the man-ufacturer. Replacement parts must be identical to thoseused in the original circuits. Services should be per-formed by q
8、ualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal
9、 injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement
10、components rated for higher voltage, watt-age, etc. Replacement parts which have these special safetycharacteristics are identified in the Parts List of Service Manu-al. Electrical components having such features are iden-tified by shading on the schematics and by ( ) on theParts List in the Service
11、 Manual. The use of a substitute re-placement which does not have the same safety character-istics as the recommended replacement parts shown in theParts List of Service Manual may create shock, fire, or oth-er hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, b
12、arriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to
13、normal, after reassembling.(5) Leakage shock hazard testing)After reassembling the product, always perform an isolationcheck on the exposed metal parts of the product (antennaterminals, knobs, metal cabinet, screw heads, headphonejack, control shafts, etc.) to be sure the product is safe tooperate w
14、ithout danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a retu
15、rn path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use an ACvoltmeter having, 1,000 ohms per volt or more sensitivity inthe following manner. Connect a 1,500 ohm 10W res
16、istorparalleled by a 0.15 F AC-type capacitor between anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metal part,particularly any exposed metal part having a return path tothe chassis, an
17、d measure the AC voltage across the resistor.Now, reverse the plug in the AC outlet and repeat eachmeasurement. Voltage measured any must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety
18、 standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector i
19、s provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-sc
20、reenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of the same typeand rating as specified by the manufa