Jvc-RX-6032-VSL-Service-Manual电路原理图.pdf
《Jvc-RX-6032-VSL-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-RX-6032-VSL-Service-Manual电路原理图.pdf(79页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.No.220122003/03RX-6032VSLAUDIO/VIDEO CONTROL RECEIVER22012200303RX-6032VSLTABLE OF CONTENTS1 Important Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
2、22 Disassembly method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . 1-124 Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13TA/NEWS/INFODISPLAY MODE DIGITAL AUTO SPK ONE TOUCH OPERATION BASS BOOSTPRO LOGIC DSP H.PHONE AUTO MUTING TUNED STEREO TA N
4、EWS INFO VOLUMEINPUT ATT EON RDS SLEEPCH12ANALOG LLINEAR PCMDIGITALC RS.WFR LFELS RSSSTANDBYSTANDBY/ONPHONES DIGITALPRO LOGICSURROUNDDSPDVD MULTISPEAKERSON/OFFSUBWOOFER OUT FM MODE MEMORYON/OFFFM/AM TUNINGDVD VCR CD FM AMTAPE/CDRTV SOUNDSURROUND/DSPOFFDIMMERINPUT DIGITALRX6030V AUDIO/VIDEO CONTROL R
5、ECEIVERSETTING MULTI JOGSETADJUSTEXITINPUT ANALOGMASTER VOLUMEINPUT ATTFM/AM RESETSOURCE NAMEArea suffixC - CanadaRX-6032VSL1-2 (No.22012)SECTION 1Important Safety Precautions1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for
6、 safety purposes.For continued protection, no changes should be made to theoriginal design unless authorized in writing by the man-ufacturer. Replacement parts must be identical to thoseused in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the de
7、sign or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3)
8、 Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, et
9、c. Replacement parts which have these special safetycharacteristics are identified in the Parts List of Service Manu-al. Electrical components having such features are iden-tified by shading on the schematics and by ( ) on theParts List in the Service Manual. The use of a substitute re-placement whi
10、ch does not have the same safety character-istics as the recommended replacement parts shown in theParts List of Service Manual may create shock, fire, or oth-er hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive par
11、ts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassembling.(5) Leakage shock haza
12、rd testing)After reassembling the product, always perform an isolationcheck on the exposed metal parts of the product (antennaterminals, knobs, metal cabinet, screw heads, headphonejack, control shafts, etc.) to be sure the product is safe tooperate without danger of electrical shock.Do not use a li
13、ne isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth grou
14、nd. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use an ACvoltmeter having, 1,000 ohms per volt or more sensitivity inthe following manner. Connect a 1,500 ohm 10W resistorparalleled by a 0.15 F AC-type capacitor bet
15、ween anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metal part,particularly any exposed metal part having a return path tothe chassis, and measure the AC voltage across the resistor.Now,
16、 reverse the plug in the AC outlet and repeat eachmeasurement. Voltage measured any must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of
17、the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 Ca
18、utionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams
19、, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of the same typeand rating as specified by the manufacturer. (Except the JC version)RX-6032VSL(No.2201
20、2)1-31.5 Importance administering point on the safety Caution: For continued protection against risk offire, replace only with same type 6.3A/125V forF201, 2A/125V for F202 and F203.This symbol specifies type of fast operating fuse.Precaution: Pour eviter risques de feux, remplacezle fusible de sure
21、te de F201 comme le meme typeque 6.3A/125V, et 2A/125V pour F202 et F203.Ce sont des fusibles suretes qui functionnes rapide.Secondary partsPrimary partCN251D205FC221FC222FC231FC232R201RY201110111 112113 114120121122 130131B192B191B160B1592A-125V2A-125VF 203F 202FC211 FC212 6.3A-125VB104PW103PW101B1
22、03B102B101B106B105PW102PW105B108B107PW104B109B110TA201TA202R1EP1RX-6032VSL1-4 (No.22012)SECTION 2Disassembly method2.1 Removing the top cover (See Fig.1)(1) From the right and left sides of the main body, remove thefour screws A attaching the top cover.(2) From the back side of the main body, remove
23、 the threescrews B attaching the top cover.(3) Remove the top cover in the direction of the arrow 2 whileextending the lower sections of the top cover in the direc-tion of the arrow 1.Fig.12.2 Removing the front panel assembly (See Figs.2 and 3) Prior to performing the following procedure, remove th
24、e topcover.(1) Disconnect the card wire from the connector CN402 on theaudio board. (See Fig.2)(2) Disconnect the card wire from the connector CN201 on thepower supply board. (See Fig.2)(3) Remove the tie band and wire protection board fixing thecard wire. (See Fig.2)(4) Remove the three screws C at
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcRX6032VSLServiceManual 电路 原理图