1、SERVICE MANUALCOPYRIGHT 2009 Victor Company of Japan, LimitedNo.MB7112009/10COMPACT COMPONENT SYSTEMMB711200910SERVICE MANUALNX-D7UX, NX-D7UN, NX-D7EE, NX-D7UW, NX-D7UH, NX-D5UG, NX-D5UX, NX-D5UN, NX-D5EE, NX-D5UW, NX-D5UHCOPYRIGHT 2009 Victor Company of Japan, LimitedLead free solder used in the bo
2、ard (material : Sn-Ag-Cu, melting point : 219 Centigrade)Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . 1-84 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-175 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5、 . . . . . . . . . . . . . . 1-18(for NX-D7) (for NX-D7/NX-D5)CA-NXD7SP-NXD7FSP-NXD7WSP-NXD7FSP-NXD7FSP-NXD7FSP-NXD7WSP-NXD7WSP-NXD7WCA-NXD51-2 (No.MB711)SPECIFICATIONAmplifier sectionOutput Power NX-D7 MAIN SPEAKERS 230 W (115 W + 115 W) at 3 (10% THD)SUBWOOFERS 230 W (115 W + 115 W) at 3 (10% THD)
6、NX-D5 MAIN SPEAKERS 230 W (115 W + 115 W) at 3 (10% THD)SUBWOOFERS 115 W at 3 (10% THD)Audio Input AUDIO IN: Stereo mini ( 3.5 mm)500 mV/47 k (at “AUDIO LVL3”)250 mV/47 k (at “AUDIO LVL2”)125 mV/47 k (at “AUDIO LVL1”)Digital Input/Output OPTICAL DIGITAL OUTPUT (output only) -21 dBm to -15 dBm (660 n
7、m 30 nm)NX-D7 Bluetooth ADPTUSB1:VIDEO/AUDIO PLAY (input only)USB2:AUDIO REC/PLAY (input and output)HDMI MONITOR OUT (output only)NX-D5 USB: REC/PLAY (input and output)HDMI MONITOR OUT (output only)VIDEO OUT Color system NTSC/PAL (interlaced/progressive)VIDEO (Composite) 1 V(p-p)/75 COMPONENT (Y) 1
8、V(p-p)/75 (PB/PR) 0.7 V(p-p)/75 HDMI MONITOR OUT 480p/576p/720p/1080i/1080pSpeaker impedance 3 - 16 Tuner sectionFM tuning range 87.50 MHz - 108.00 MHzAM tuning range 531 kHz - 1 710 kHz (at 9 kHz)530 kHz - 1 710 kHz (at 10 kHz)Disc player sectionRegion codes Middle East 2South East Asia 3Central an
9、d South America, Australia 4Dynamic range 80 dBHorizontal resolution 500 linesWow and flutter ImmeasurableUSB sectionRecording format MP3/WMA formatUSB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible system FAT16, FAT32Bus power supply DC 5 V 500 mABlue
10、tooth section (NX-D7)Version Bluetooth ver. 2.0 + EDR Class 1/Class 2Compatible Bluetooth profile A2DP, AVRCPCommunication format 2.4 GHz FHSSHDMI sectionOutput power DC 5 V 55 mA(No.MB711)1-3Design and specifications are subject to change without notice.GeneralPower requirements AC 110 - 127/220 -
11、240 V , 50/60 HzFor Australia: AC 240 V , 50 Hz, For Russia: AC 230V , 50 HzPower consumption NX-D7 130 W (at operation)/21 W (at standby) /1 W or less (at ECO mode)NX-D5 85 W (at operation)/16 W (at standby) /1 W or less (at ECO mode)Dimensions (approx.) 195 mm 333 mm 313 mm (W H D)Mass (approx.) 3
12、.5 kgMain SpeakerType 3-way 3-speaker Bass Reflex Type (Magnetically-Shielded Type)Speaker units Tweeter 2.0 cm cone 1Mid Range 5.0 cm cone 1Woofer 16.0 cm cone 1Impedance 3 Power handling capacity 115 WFrequency range 40 Hz - 20 000 HzSound pressure level 84 dB/W/mDimensions (W H D) 205 mm 409.5 mm
13、 290.5 mmMass 3.6 kg eachSubwooferType 1-Way Bass Reflex Type (Magnetically-Shielded Type)Speaker units 16.0 cm cone 1Impedance 3 Power handling capacity 115 WFrequency range 40 Hz - 5 000 HzSound pressure level 83 dB/W/mDimensions (W H D) 205 mm 409.5 mm 290.5 mmMass 3.5 kg1-4 (No.MB711)SECTION 1PR
14、ECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be
15、 identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufactu
16、rers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection n
17、or can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare
18、identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4)
19、 The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress
20、should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw head
21、s,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each expos
22、ed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per
23、volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, p
24、articularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This