Jvc-RCBX-30-Service-Manual电路原理图.pdf
《Jvc-RCBX-30-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-RCBX-30-Service-Manual电路原理图.pdf(30页珍藏版)》请在收音机爱好者资料库上搜索。
1、RC-BX30No.21171Dec. 2002COPYRIGHT 2002 VICTOR COMPANY OF JAPAN, LTD.SERVICE MANUALContentsSafety precautionsPreventing static electricityImportant for laser productsDisassembly methodAdjustment methodTrouble shooting1-21-31-41-51-141-17RC-BX30Area suffixUJ - U.S.MilitaryFlow of functional operationu
2、ntil TOC readMaintenance of laser pickupReplacement of laser pickupDescription of major ICsWiring connection1-181-191-191-201-22CD PORTABLE SYSTEMRC-BX301-21. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protectio
3、n, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should n
4、ot be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts
5、 in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these
6、special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac
7、teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving part
8、s and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5. Leakage currnet check (Electrical shock hazard testin
9、g)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line i
10、solation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a “Leakage Current Tester“, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground.
11、 Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between a
12、n exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now,
13、reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repaire
14、r to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groun
15、dPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In regard with
16、component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the “ “ mark nearby are critical for safety. (This regulation does not correspond to J and C version
17、.)RC-BX301-3Conductive material (conductive sheet) or iron plate(caption)Anti-static wrist strapShort landFiexible wireCD pickup unit5. Attention when traverse unit is decomposed*Please refer to “Disassembly method“ in the text for the CD pickup unit. Apply solder to the short land before the flexib
18、le wire is removedfrom the CD servo board. (If the flexible wire is disconnected without applying solder, the CDpickup unit may be destroyed by static electricity.) In the assembly, be sure to remove solder from the short land after connecting the fiexible wire.Electrostatic discharge (ESD), which o
19、ccurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.Preventing static electricity1. Grounding to prevent damage by static electricityStatic electricity in th
20、e work area can destroy the optical pickup (laser diode) in devices such as CD players.Be careful to use proper grounding in the area where repairs are being performed. 2. About the earth processing for the destruction prevention by static electricityGround the workbench by laying conductive materia
21、l (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it.2-1 Ground the workbench2-2 Ground yourselfUse an anti-static wrist strap to release any static electricity built up in your body.In order to maintain quality during transport and before i
22、nstallation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power sourc
23、e can easily destroy the laser diode. 3. Handling the optical pickup1.2.Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit.Remove solder of the short land on the flexible wire after replacing the optical pickup. For specific details, refer to the r
24、eplacement procedure in the text. Remove the anti-static pin when replacing the traverse unit.Be careful not to take too long a time when attaching it to the connector.Handle the flexible wire carefully as it may break when subjected to strong force.It is not possible to adjust the semi-fixed resist
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcRCBX30ServiceManual 电路 原理图