1、STROMBERG-CARLSON niodel APH-1100 100 watt audio power amplifier SPECIFICATIONS OUTPUT POWER -100 watts with less than 5% harmonic distortion from 50-15, 000 cps, 80 watts with less than 2% harmonic distortion from 40-20, 000 cps. FREQUENCY RESPONSE -20-30, 000 cps ldb, high pass filter out 10-70, 0
2、00 cps 4db, high pass filter out IM DISTORTION -3. 5% maximL1m with 4:1 ratio of 60 cps and 7KC INPUT SENSITIVITY -1. volts into 250, 000 ohms un- balanced; . 5 volts into 10, 000 ohms balanced line HUM AND NOISE - SOdb below 100 watts REGULATION INPUTS -Full load to no load less than 2db - One inpu
3、t; amplifier may be operated with a 250K ohm unbalanced input or, when an input transformer is used with a lOK ohm balanced input GIIIIIIIID GENERAL CJVNAMICS OUTPUT CONTROLS -70V and 25V center tapped constant voltage line and 115V aulio output receptacle. -Input level control, DC balance and Bias
4、Adjustment Controls POWER SOURCE -105-125 volts AC, 50-60 cps POWER CONSUMPTION- 175 watts TUBE AND DIODE COMPLEMENT 1 - 7199 2 -6550 2-1Nl764 1 -1Nl873 Voltage amplifier and phase splitter Power Outputs Rectifiers (full wave) Bias Supply Rectifier ACCESSORIES Standby Relay -172000-015, Model No. RS
5、-1012 Input Transformer -172000-065, Model No. TB-1011 Hinge Kit -SC-1102 Amplifier Panel -SCP-1101 ELECTRONICS ROCHESTER 146011-204 . = Ol e+- . . e+- . 0 = 收音机爱好者资料库 Ra d i o Fa n s .CN GENERAL DESCRIPTION The APH-1100 is a high quality, 100 watt amplifier de- signed for use in school systems and
6、in commercial rack and shelf mounted applications. Rack mounting of this unit may be facilitated by the use of an accessory hinge kit (SC-1102) containing a hinged bracket for use in pro- viding the amplifier with a swing out for service feature. An amplifier panel with pilot light opening (SCP-1101
7、) is also available for rack mounting. A standby relay, Model No. RS-1012 (Part no. 172000- 015), can be accomodated by the relay socket provided on the amplifier chassis. Twenty four volts DC (24 VDC) applied to terminals Kl and K2 will energize the relay and ground the cathodes of the output tubes
8、, placing the amplifier in its ready mode of operation. The APH-1100 has a high impedance (250K ohm) un- balanced input with provision for the installation of an input matching transformer, Model No. TB-1011 (part no. 172000-065). This accessory will provide isolation from the input source and permi
9、t balanced operation from a source of lOK ohms or less. SERVICE INFORMATION Power Transformer The power transformer of the APH-1100 features a tapped primary winding for either 117V or 125V operation. Connections for the two voltage ranges are as follows- White lead common, Black and White lead 117V
10、 tap, Black lead 125V tap. All amplifiers shipped from the factory will be connected for 125 volt operation. Should the line voltage in your locality be consistently below 125 volts reconnect to the 117V tap. Input Transformers Inputs with an impedance of lOK ohms may be impedance matched to the amp
11、lifier by the addition ofan input trans- former 172000-065 which plugs into the socket provided on the amplifier chassis. NOTE: Before installing this transformer remove the plug-in jumper between pins 3 and 4 of the socket. If an unbalanced high impedance input is to be connected to the amplifier t
12、he transformer must be removed and the jumper reinserted. As many as four (4) APH-1100 amplifiers may be oper- ated in parallel from either the Stromberg-Carlson SCP- 1003 or SCP-1005 preamplifier. Standby Relays A Standby Relay, 172000-015, available as an accessory, may be used as an output tube c
13、ut-off to place the ampli- fier in its standby mode. Before installing the Standby Relay the plug-in jumper between pins 5 and 6 of the relay socket (on amplifier) must be removed. If, at any time, the Standby Relay is removed this jumper must be reinserted. Once the relay is installed twenty four (
14、24) volts DC ap- plied to terminals Kl and K2 on the amplifier terminal strip will energize the relay and apply a ground to the cathodes of the output tubes, placing the amplifier in its ready mode. CONTROLS AND ADJUSTMENTS Power Output Stage Bias Adjustment -DC Balance Controls The Bias Adjustment
15、Control provides a sufficient degree of adjustment to allow the employment of unmatched output tubes in the Power Output stage. The use of matched pairs of output tubes however, will aid in bias adjustment and provide optimum conditions for high fi- delity output and peak power. Occasionally, it wil
16、l be found that some tubes cannot be balanced regardless of the Bias Adjustment Control setting; when this occurs replace one or b6th of the tubes in a push pull pair until balance is obtained. The DC Balance Control is provided to allow readjustment of the amount of Plate Current in the output stag