E250p_p12sw_sm 电路图 维修原理图.pdf
《E250p_p12sw_sm 电路图 维修原理图.pdf》由会员分享,可在线阅读,更多相关《E250p_p12sw_sm 电路图 维修原理图.pdf(31页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Models: Northridge E-Series E250P Performance Series P12SW Powered Subwoofers Service Manual JBL Consumer Products 250 Crossways Park Dr. Woodbury, New York 11797 Rev3 4/2006 收音机爱好者资料库 Ra d i o Fa n s .CN - CONTENTS - BASIC SPECIFICATIONS .1 SAFETY INFORMATION .2 E250P PACKING.3 P12SW PACKING.4 DET
2、AILED SPECIFICATIONS .5 CONNECTIONS.6 OPERATION .9 BASIC TROUBLESHOOTING.10 E250P EXPLODED VIEW/PARTS LIST.11 P12SW EXPLODED VIEW/PARTS LIST.12 TEST SET-UP AND PROCEDURE.13 AMPLIFIER BLOCK DIAGRAM14 E250P BULLETIN JBL2005-01. .15 E250P/P12SW TECH TIP JBLTT2003-04 .16 DETAILED TROUBLESHOOTING.17 P.C.
3、B. DRAWINGS.20 ELECTRICAL PARTS LIST .24 IC/TRANSISTOR PINOUTS.28 SCHEMATICS.29 E250P, P12SW SPECIFICATIONS Amplifier Power (RMS): 250 Watts Peak Dynamic Power *: E250P: 550 Watts P12SW: 500 Watts Driver: 12 (305mm) PolyPlas Inputs: Line Level (switchable to LFE) and Speaker Level with 5-way binding
4、 posts Low-Pass Frequency: Variable from 50Hz to 150Hz Frequency Response: 25Hz Low-pass crossover setting Dimensions (H x W x D): 19-3/4 x 14-3/8 x 16-1/2 (502mm x 365mm x 419mm) Weight: 43 lb/19.5kg JBL continually strives to update and improve existing products, as well as create new ones. The sp
5、ecifications and details in this and related JBL publications are therefore subject to change without notice. * The Peak Dynamic Power is measured by recording the highest center-to-peak voltage measured across the output of a resistive load equal to minimum impedance of the transducer, using a 50Hz
6、 sine wave burst, 3 cycles on, 17 cycles off. E250P/P12SW subwoofers E250P/P12SW subwoofers 收音机爱好者资料库 Ra d i o Fa n s .CN Warning Any person performing service of this unit will be exposed to hazardous voltages and the risk of electric shock. It is assumed that any person who removes the amplifier f
7、rom this cabinet has been properly trained in protecting against avoidable injury and shock. Therefore, any service procedures are to be performed by qualified service personal ONLY! Caution Early revisions of the unit did not have a power switch. Hazardous voltages are resent within the unit whenev
8、er it is plugged in. Before amplifier is plugged in, be sure its rated voltage corresponds to the voltage of the AC power source to be used. Incorrect voltage could cause damage to the amplifier when the AC power cord is plugged in. Do not exceed rated voltage by more than 10%: operation below 90% o
9、f rated voltage will cause poor performance or may shut the unit off. Leakage/Resistance Check Before returning the unit to the customer, perform a leakage or resistance test as follows: Leakage Current. Note there is no power switch on early revisions of this unit. When the power plug is plugged in
10、, the unit is live. Connect the unit to its rated power source. Using an ammeter, measure the current between the neutral side of the AC supply and chassis ground of the unit under test. If leakage current exceeds 0.5mA, the unit is defective. Reverse the polarity of the AC supply and repeat. Resist
11、ance. Measure the resistance from either side of the line cord to chassis ground, If it is less than 500k ohms, the unit is defective. WARNING! DO NOT return the unit to the customer if it fails one of these tests until the problem is located and corrected. Critical Components All components identif
12、ied with the IEC symbol in the parts list and schematic diagram designate components in which safety can be of special significance when replacing identified with. Use only the replacement parts designated in the parts list or parts with the same rating of resistance, wattage or voltage. SAFETY INFO
13、RMATION List of Safety Components Requiring Exact Replacements Part Number/ Designator Description F1 093-105202-300 Line Fuse Slo Blo 2.0A 5x20mm 083-041802-009 250V UL approved SPT-2 or better with polarized plug, UL approved wired with the hot side to fused side. Use with factory replacement pane
14、l strain relief (70305) only. PT1 042-010053-003 Power Transformer. Use only factory replacement. BR1 052-400080-000 Bridge diode. Use only factory replacement. C6,8 034-330780-300 3300uF 80V electrolytic filter caps. Be sure replacement part is at least the same working voltage and capacitance rati
15、ng. Also the lead spacing is important. Incorrect spacing may cause premature failure due to internal cabinet pressure and vibration. 063-531808-000 Rear Amp Cover Use only factory replacement Inductor 043-560200-000 L1 - Use only factory replacement Inductor 043-300101-000 L2 - Use only factory rep
16、lacement Inductor 043-700101-000 L3 - Use only factory replacement Inductor 043-324300-000 L4 - Use only factory replacement E250P/P12SW subwoofers E250P/P12SW subwoofers 收音机爱好者资料库 Ra d i o Fa n s .CN 15 3 14 2 4 E250P Packaging Ref# Part Number Description Qty 1 351249-002 MANUAL, OWNER-E250P/E250P
17、 1 2 351249-001 CARTON,MASTER-E250P (BEECH MODEL) 1 351249-003 CARTON,MASTER-E250P (BLACK MODEL) 1 350884-003 CARTON,MASTER-E250P (CHERRY MODEL) 1 3 351252-001 PAD,END,TOP-E250P 1 4 351252-002 PAD,END,BOT-E250P 1 5 338381-001 WARRANTY CARD,1/5YR,JBL 1 14 352024-001 ASY, GRILLE, BLK, FRNT 1 3 15 3 2
18、4 Packaging P12SW 6 Ref# Part Number Description Qty 1 361803-001 P12SW Owners Manual 1 2 361813-001 P12SW Outer Carton 1 3 351252-001 Packing Foam (Top) 1 4 351252-002 Packing Foam (Bottom) 1 5 338381-001 Warranty Card 1 6 352024-003 Front Grille 1 4 JBL E250P/P12SW Powered Sub/ Plate Amp LINE VOLT
19、AGEYes/NoHi/Lo LineNom.UnitNotes US 120vac/60HzYes108-132120VrmsNormal Operation EU 230vac/50-60HzYes207-264230VrmsNormal operation, MOMS required ParameterSpecificationUnit QA Test LimitsConditionsNotes Amp Section Type (Class AB, D, other)Dn/an/a Load Impedance (speaker)5.6Ohmsn/aNominal Rated Out
20、put Power (120VAC150Watts140Domestic version only 120 VAC-60 Hz Rated Output Power (230VAC150Watts130EU Version only 230 VAC-50 Hz AVG RMS Dynamic Power250Watts225 Average RMS power, 3/20 Cycles 50 Hz, Driven 6dB above its input sensitivity sensitivity THD Rated Power0.3%122k filter145 Watts THD 1 W
21、att0.1%0.522k filter DC Offset10mV-DC30 Speaker Outputs Damping factor50DF35Measured at amplifier board Measured at the speaker cable. 150 Watts THD 4.7Kohmsn/aNominal Filters LP filter 4th order fixed60-180 Hz 102nd order variable + 2nd order fix-24 db/Octave Subsonic filter (HPF) 3rd OrdeFixed LFE
22、 Low pass 2nd order200LP T 1M (NO LOAD) Resistance from V+ (C6 P+) to V- (C8 P-) gradually Fully CHARGED should read 10k Resistance from V+ (C6 P+) to S+ (SPK O/P) should read 1M Resistance from V- (C8 P-) to S+ (SPK O/P) should read 1M 2. Power UpLED RED With a 5mV signal to Low level input, LED sh
23、ould change to GREEN -Voltage measurements (DVM) OP AMP LEDP-U4(1)P-U4(7) RED0Vrms11.84VDC GREEN7.13Vrms-12.93VDC 3. D.C. Operation -Voltage measurements (DVM) on CLASS D POWER AMP BetweenV+Q4(E)Q1(C)Q10(C)U7(1)U7(2)U7(4)U7(6)U7(7)U7(8) And This Point GNDV-GNDGNDGNDGNDGNDGNDGNDGND Get this Reading 7
- 配套讲稿: