Alesis_microverb_4_1 电路图 维修原理图.pdf
《Alesis_microverb_4_1 电路图 维修原理图.pdf》由会员分享,可在线阅读,更多相关《Alesis_microverb_4_1 电路图 维修原理图.pdf(11页珍藏版)》请在收音机爱好者资料库上搜索。
1、Confidential Alesis Service Manual 8-31-0023-B ALESIS MicroVerb 4 (C4) Service Manual P/N: 8-31-0023-B The information in this document contains privileged and confidential information. It is intended only for the use of those authorized by Alesis. If you are not the authorized, intended recipient,
2、you are hereby notified that any review, dissemination, distribution or duplication of this document is strictly prohibited. If you are not authorized, please contact Alesis and destroy all copies of this document. You may contact Alesis at or at . Copyright Alesis, LLC ATTENTION! THIS DOCUMENT CONT
3、AINS SENSITIVE PROPRIETARY INFORMATION. ALL RECIPIENTS MUST HAVE A CURRENT NON-DISCLOSURE AGREEMENT ON FILE WITH ALESIS, LLC. DO NOT MAKE ILLEGAL COPIES OF THIS DOCUMENT 收音机爱好者资料库 Ra d i o Fa n s .CN 10-22-02 Microverb (C4) General Description The Alesis MicroVerb IV is the latest in the line of pop
4、ular effects processors of the micro series. Similar in performance to the MicroVerb, the NanoVerb is a scaled down version. Combining the well known power of Alesis custom processing with small size and affordability, the MicroVerb IV (Product Code C4) and NanoVerb (Product Code NV) are based large
5、ly on the design of the MidiVerb IV. The MidiVerb IV custom chip set, along with the latest ADC and DAC technology help make the C4 and NV two of the most powerful signal processors in their price ranges. Particularly in the NV the use of surface mount technology helps push the envelope of size and
6、weight verses performance. Reference designators for the C4 are taken from the Rev. C schematic. Reference designators for the NV are taken from the Rev. B schematic and are denoted by brackets when components are functionally similar to the C4. Note that for both of these units there are several di
7、fferent main PCB revisions. There are no functional differences between these revisions. However, it should be noted that older PCB revisions will have some wire jumpers that later rev.s incorporated into the PCBs. Figure 1 shows the simplified block diagram of the C4. As the NanoVerb is even simple
8、r, there is no need to simplify it beyond the schematic. Figure 1 C4 Service Manual Confidential V1.01 收音机爱好者资料库 Ra d i o Fa n s .CN 10-22-02 Test Procedures C4 Self Test The MicroVerb 4 has two self test modes which allow the user to run diagnostic tests. In Individual Test mode, the user can selec
9、t particular tests to run. In All Test mode, the MicroVerb 4 runs all of the tests in series. - Power up the unit while holding down the Bank button. To enter Individual Test mode: - Use the Value Dial to select which test to run (each test is described below). - Press Store to execute the test. Whe
10、n the test is complete, you can either select another test to run or exit Individual Test mode by holding Bank and pressing Store. - Power up the unit while holding down the Store button. To enter All Test mode: C4 Individual Test Descriptions 4 t0: ROM Test. If the unit passes, the MicroVerb 4 will
11、 display P0 and exit the test automatically. If the unit fails, the MicroVerb 4 will display F0 and wont exit the test. In this case, the user must press Bank to exit. 4 t1: EEPROM Test. If the unit passes, the MicroVerb 4 will display P1 and exit the test automatically. If the unit fails, the Micro
12、Verb 4 will display F1 and wont exit the test. In this case, the user must press Bank to exit. 4 t2: LED Test. Lights up all the LEDs (first, column by column; then row by row). The C4 automatically exits this test. 4 t3: Switch/Encoder Test. Checks the buttons and the rotary encoder. The user must
13、press every button AND rotate the encoder in both directions in order for the test to pass. After doing this, the user should hold Bank and press Store. If at this point all of the buttons have been pressed (i.e., the unit passed), then the MicroVerb 4 will display P3 and exit the test. If instead n
14、ot all of the buttons have been pressed, the MicroVerb 4 will display F3. The user can either restart the test (by pressing Store) or exit the test (by pressing Bank.) 4 t4: Edit Knob Test. Checks the Edit A/B knobs. The user must rotate each knob to show all values (0 to 127) in order for the test
15、to pass. To exit the test, press Bank. 4 t5: MIDI In/Out Test. Before running this test the user must connect a MIDI cable from the MIDI Out to the MIDI In of the unit. If the unit passes, the MicroVerb 4 will display P5 and exit the test. If the unit fails, the MicroVerb 4 will display F5 and wont