Pioneer-SX518S-rec-sm 维修电路原理图.pdf
《Pioneer-SX518S-rec-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-SX518S-rec-sm 维修电路原理图.pdf(94页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO.PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, JapanPIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, BelgiumPIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Sin
2、gapore 159936 PIONEER CORPORATION20082008 Printed in JapanMASTERVOLUMEVSX-518STANDBY/ONPHONESDVDTVDVD 5.1DVRCDCD-RFMAMMIDNIGHT/LOUDNESSVSB MODESIGNALSELECTSOUNDRETRIEVERPORTABLEPORTABLESLEEPPHASECONTROLINPUTSELECTORADVANCEDSURROUNDSTEREO /A.L.C.STANDARDAUDIO/VIDEO MULTI-CHANNEL RECEIVERDIALOGUEENHAN
3、CEMENTPHASECONTROLAUTO SURR /STREAM DIRECTVSX-518-KRRV3707AUDIO/VIDEO MULTI-CHANNEL RECEIVERVSX-518-KVSX-518-STHIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).ModelTypePower RequirementRemarksVSX-518-KKUCXJAC 120 VVSX-518-SKUCXJAC 120 VFor details, refer to Important Check Points for
4、good servicing. T-ZZK JAN.RadioFans.CN 收音机爱 好者资料库2VSX-518-K1234ABCDEF1234SAFETY INFORMATION This service manual is intended for qualified service technicians; it is not meant for the casualdo-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have beentrained to pr
5、operly and safely repair complex products such as those covered by this manual.Improperly performed repairs can adversely affect the safety and reliability of the product and mayvoid the warranty. If you are not qualified to perform the repair of this product properly and safely, youshould not risk
6、trying to do so and refer the repair to a qualified service technician.WARNINGThis product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California tocause cancer, birth defects or other reproductive harm.Health & Safety Code Section 25249.6 P
7、roposition 65NOTICE(FOR CANADIAN MODEL ONLY)Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacementparts must be of identical designation.REMARQUE(POUR MODLE CANADIEN SEULEMENT)Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur
8、CCI indiquent queles pices de remplacement doivent avoir la mme dsignation.ANY MEASUREMENTS NOT WITHIN THELIMITS OUTLINED ABOVE ARE INDICATIVEOF A POTENTIAL SHOCK HAZARD ANDMUST BE CORRECTED BEFORE RETURN-ING THE APPLIANCE TO THE CUSTOMER.2. PRODUCT SAFETY NOTICEMany electrical and mechanical parts
9、in the appliancehave special safety related characteristics. These areoften not evident from visual inspection nor theprotection afforded by them necessarily can be obtained by using replacement components rated for voltage,wattage, etc. Replacement parts which have thesespecial safety characteristi
10、cs are identified in thisService Manual.Electrical components having such features are identified by marking with a on the schematics andon the parts list in this Service Manual.The use of a substitute replacement component whichdoes not have the same safety characteristics as thePIONEER recommended
11、 replacement one, shown in theparts list in this Service Manual, may create shock, fire,or other hazards.Product Safety is continuously under review and newinstructions are issued from time to time. For the latestinformation, always consult the current PIONEERService Manual. A subscription to, or ad
12、ditional copiesof, PIONEER Service Manual may be obtained at anominal charge from PIONEER.(FOR USA MODEL ONLY)1. SAFETY PRECAUTIONSThe following check should be performed for thecontinued protection of the customer and servicetechnician.LEAKAGE CURRENT CHECKMeasure leakage current to a known earth g
13、round(water pipe, conduit, etc.) by connecting a leakagecurrent tester such as Simpson Model 229-2 orequivalent between the earth ground and all exposedmetal parts of the appliance (input/output terminals,screwheads, metal overlays, control shaft, etc.). Plugthe AC line cord of the appliance directl
14、y into a 120VAC 60 Hz outlet and turn the AC power switch on. Anycurrent measured must not exceed 0.5 mA.DeviceundertestLeakagecurrenttesterEarthgroundReading shouldnot be above0.5 mAAlso test withplug reversed(Using AC adapterplug as required)Test allexposed metalsurfacesAC Leakage TestRadioFans.CN
15、 收音机爱 好者资料库3VSX-518-K56785678ABCDEF4VSX-518-K1234ABCDEF1234CONTENTS SAFETY INFORMATION.21. SERVICE PRECAUTIONS.51.1 NOTES ON SOLDERING .51.2 AMPLIFIER FAILURE DIAGNOSIS FLOW CHART.52. SPECIFICATIONS.62.1 SPECIFICATIONS.62.2 PANEL FACILITIES.73. BASIC ITEMS FOR SERVICE.123.1 CHECK POINTS AFTER SERVIC
16、ING.123.2 PCB LOCATIONS .134. BLOCK BIAGRAM.144.1 OVERALL WIRING CONNECTION DIAGRAM .144.2 BLOCK DIAGRAM.164.3 DSP BLOCK DIAGRAM.185. DIAGNOSIS.195.1 DIAGNOSIS FLOWCHART (DSP ASSY) .195.2 DETECTION CIRCUIT.235.3 AMPLIFIER SYSTEM PROTECTION OPERATION SPECIFICATION.256. SERVICE MODE.267. DISASSEMBLY.2
17、78. EACH SETTING AND ADJUSTMENT .299. EXPLODED VIEWS AND PARTS LIST.309.1 PACKING .309.2 EXTERIOR SECTION.329.3 REAR PANEL SECTION.349.4 FRONT PANEL SECTION .3610. SCHEMATIC DIAGRAM.3810.1 MAIN ASSY (1/3).3810.2 MAIN ASSY (2/3).4010.3 MAIN ASSY (3/3).4210.4 DSP ASSY (1/2).4410.5 DSP ASSY (2/2).4610.
18、6 POWER PACK (1/2) and TRANS2 ASSY.4810.7 POWER PACK ASSY (2/2) .5010.8 COMPONENT VIDEO, 5.1CH INPUT and TRANS3 ASSYS .5210.9 FRONT DISPLAY, ROTARY ENCODER, POWER KEY and JOG ASSYS.5410.10 FRONT MINI JACK, DIGITAL INPUT, REGULATOR and HEAD PHONE ASSYS.5610.11 VIDEO, PRIMARY and TRANS1 ASSYS.5811. PC
19、B CONNECTION DIAGRAM .6011.1 DSP ASSY.6111.2 MAIN ASSY .6211.3 POWER PACK ASSY.6611.4 TRANS2 and TRANS3 ASSYS.7011.5 COMPONENT VIDEO ASSY.7211.6 5.1CH INPUT and HEAD PHONE ASSYS .7311.7 FRONT DISPLAY, ROTARY ENCODER, POWER KEY and JOG ASSYS.7411.8 DIGITAL INPUT ASSY.7811.9 REGULATOR ASSY.7911.10 VID
20、EO ASSY .8011.11 FRONT MINI JACK ASSY.8111.12 TRANS1 and PRIMARY ASSYS.8212. ELECTRICAL PARTS LIST .845VSX-518-K56785678ABCDEF1. SERVICE PRECAUTIONS1.1 NOTES ON SOLDERING1.2 AMPLIFIER FAILURE DIAGNOSIS FLOW CHART For environmental protection, lead-free solder is used on the printed circuit boards mo
21、unted in this unit. Be sure to use lead-free solder and a soldering iron that can meet specifications for use with lead-free solders for repairs accompanied by reworking of soldering. Compared with conventional eutectic solders, lead-free solders have higher melting points, by approximately 40 C. Th
22、erefore, for lead-free soldering, the tip temperature of a soldering iron must be set to around 373 C in general, although the temperature depends on the heat capacity of the PC board on which reworking is required and the weight of the tip of the soldering iron.Do NOT use a soldering iron whose tip
23、 temperature cannot be controlled.Compared with eutectic solders, lead-free solders have higher bond strengths but slower wetting times and higher melting temperatures (hard to melt/easy to harden).The following lead-free solders are available as service parts: Parts numbers of lead-free solder: GYP
24、1006 1.0 in dia. GYP1007 0.6 in dia. GYP1008 0.3 in dia.Amplifier failure diagnosis flow chartWhen DC detection is activated (AMP_ERR flashes on the display), failure (damage) of the power amplifier section is considered.Caution:When releasing the lock state of power key before repair, please be car
25、eful because there is the possibility that more damages will occur when turning on the power once again! According to a symptom, perform the following confirmation beforehand.1) Are there any Fuses and IC protectors open? 2) After turn on the power, confirm that the supply voltage of the point that
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Pioneer-SX518S-rec-sm 维修电路原理图 Pioneer SX518S rec sm 维修 电路 原理图