1、SERVICE MANUALThis manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are alreadyknown and understood by the users, and have therefore not b
2、een restated.WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personalinjury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,we advise all YAMAHA product owners that any service r
3、equired should be performed by an authorized YAMAHARetailer or the appointed service representative.IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification orrecognition of any applicable technical capabilities, or establish a prin
4、ciple-agent relationship of any form.The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and servicedepartments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable andspecifi
5、cations are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact thedistributors Service Division.WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may haveaccumulated by grounding your
6、self to the ground buss in the unit (heavy gauge black wires connect to this buss).IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.IMPORTANT NOTICE100979SERVICE MANUALSTEREO RECEIVERIC DATA . . . . . . . . . . . . . . . . . . .
7、 . . . . . . . . . . . . . 1718DISPLAY DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19PRINTED CIRCUIT BOARD . . . . . . . . . . . . . . . . 2028PIN CONNECTION DIAGRAM . . . . . . . . . . . . . . . . . 29BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . 30SCHEMATIC
8、 DIAGRAM . . . . . . . . . . . . . . . . . . . 3134PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3543REMOTE CONTROL RAX100/RAX101 . . . . . . . . . . 44REMOTE CONTROL RAX17 . . . . . . . . . . . . . . . . . . 45REMOTE CONTROL RAX18 . . . . . . . . . . . . . . . . . . 46I CONTE
9、NTSTO SERVICE PERSONNEL . . . . . . . . . . . . . . . . . . . . 2IMPEDANCE SELECTOR . . . . . . . . . . . . . . . . . . . . . . 3FRONT PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3REAR PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45REMOTE CONTROL PANELS . . . .
10、 . . . . . . . . . . . . . . 5SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 67INTERNAL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7DISASSEMBLY PROCEDURES . . . . . . . . . . . . . . . . . 8SELF DIAGNOSIS FUNCTION . . . . . . . . . . . . . . . 915AMP ADJUSTMEN
11、T . . . . . . . . . . . . . . . . . . . . . . . . . 16DPX-1200RX-797RX-797 2005 YAMAHA CORPORATION. All rights reseved.This manual is copyrighted by YAMAHA and may not be copied orredistributed either in print or electronically without permission. 05.10RadioFans.CN 收音机爱 好者资料库2RX-797RX-797I TO SERVIC
12、E PERSONNEL1. Critical Components InformationComponents having special characteristics are marked Zand must be replaced with parts having specifications equalto those originally installed.2. Leakage Current Measurement (For 120V Models Only)When service has been completed, it is imperative to verify
13、that all exposed conductive surfaces are properly insulatedfrom supply circuits.GMeter impedance should be equivalent to 1500 ohms shuntedby 0.15F.AC LEAKAGETESTER OREQUIVALENTEQUIPMENTUNDER TESTINSULATINGTABLEWALLOUTLETGLeakage current must not exceed 0.5mA.GBe sure to test for leakage with the AC
14、plug in bothpolarities.WARNING: CHEMICAL CONTENT NOTICE!The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/orplastic (where applicable) components may also contain traces of chemicals found by the California Health andWelfare Agency (and pos
15、sibly other entities) to cause cancer and/or birth defects or other reproductive harm.DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FORANY REASON WHATSOEVER!Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumeso
16、r expose eyes to solder/flux vapor!If you come in contact with solder or components located inside the enclosure of this product, wash your handsbefore handling food.About Lead Free SolderThe P.C.B.s installed in this unit are soldered using the following solder.“CAUTION”“F251, F252 : FOR CONTINUED
17、PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 8A, 125V FUSE.”CAUTIONF251, F252 : REPLACE WITH SAME TYPE 8A, 125V FUSE.ATTENTIONF251, F252 : UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 8A, 125V.A VSI DE ASI DE BFUNCTI ON P. C. B.Lead Free SolderOPERATI ON P. C. B.Lead Free SolderMA
18、I N P. C. B.Lead Free SolderXM P. C. B.Lead Free SolderLead Free SolderSide ASide BSMT REFLOW ProcessMI FLOW ProcessSolder DipAmong some types of lead free solder currently available, itis recommended to use one of the following types for therepair work. Sn + Ag + Cu (tin + silver + copper) Sn + Cu
19、(tin + copper) Sn + Zn + Bi (tin + zinc + bismuth)Caution:1. As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the leadsolder, be sure to use a soldering iron suitable to each solder.2. If lead solder must be used, be sure to remove lead fr
20、ee solder from each terminal section of the parts to be replaced and fromthe area around it completely before soldering, or make sure that the lead free solder and lead solder melt together fully.RadioFans.CN 收音机爱 好者资料库3RX-797DPX-1200RX-797I IMPEDANCE SELECTORWARNING:Do not change the setting of the
21、 IMPEDANCE SELECTOR switchwhen the unit power is switched on, as doing so may damagethe unit.I FRONT PANELSM U, C modelsM R, A, G, E, L modelsIMPEDANCE SELECTOR4RX-797RX-797I REAR PANELSM U, C modelsM R modelM A model5RX-797DPX-1200RX-797M G, E modelsM L modelI REMOTE CONTROL PANELSM RAX100(U, C mod
22、els)M RAX101(R, A, G, E, L models)M RAX17(U, C models)M RAX18(R, A, G, E, L models)6RX-797RX-797I SPECIFICATIONSAUDIO SECTIONMinimum RMS Output Power (Power Amp. Section)L/R, 20 Hz to 20 kHz, 0.019% THD, 8 ohms . . . .100 W + 100 WL/R, 20 Hz to 20 kHz, 0.03% THD, 6 ohms . . . . .120 W + 120 WDynamic
23、 Power Per Channel (IHF)8/6/4/2 ohms . . . . . . . . . . . . . . . . . . . . . . .140/170/220/290 WMaximum Power Per Channel (G, E models)1 kHz, 0.7 % THD, 4 ohms . . . . . . . . . . . . . . . . . . . . . . . .160 WIEC Power (G, E models)1 kHz, 0.019% THD, 8 ohms . . . . . . . . . . . . . . . . . .
24、. . . .115 WMaximum Power (EIAJ) (R, L models)1 kHz, 10% THD, 8 ohms . . . . . . . . . . . . . . . . . . . . . . . . .145 W1 kHz, 10% THD, 6 ohms . . . . . . . . . . . . . . . . . . . . . . . . .170 WPower Band WidthL/R, 0.03% THD, 50 W, 8 ohms . . . . . . . . . . . .10 Hz to 50 kHzDamping Factor20
25、Hz to 20 kHz, SPEAKER-A, 8 ohms . . . . . . . . .240 or moreInput Sensitivity/Input ImpedancePHONO MM . . . . . . . . . . . . . . . . . . . . . . . . .3.0 mV/47 k-ohmsCD, etc. . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 mV/47 k-ohmsMAIN IN . . . . . . . . . . . . . . . . . . . . . . .