Pioneer-PLX1000-tt-sm 维修电路原理图.pdf
《Pioneer-PLX1000-tt-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-PLX1000-tt-sm 维修电路原理图.pdf(44页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO.PIONEER CORPORATION 1-1, Shin-ogura, Saiwai-ku, Kawasaki-shi, Kanagawa 212-0031, JapanPIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, BelgiumPIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road
2、, #04-01, Singapore 1599362014 Printed in JapanPLX-1000RRV4511TURNTABLEPLX-1000THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).ModelTypePower RequirementRemarksPLX-1000LPSYXE8AC 110 V to 120 V or 220 V to 240 VPLX-1000FUXECBAC 110 V to 120 V or 220 V to 240 VK-MZV AUG.RadioFans.CN 收音
3、机爱 好者资料库2PLX-10001234ABCDEF1234SAFETY INFORMATION WARNINGThis product may contain a chemical known to the State of California to cause cancer, or birth defects or other reproductive harm.Health & Safety Code Section 25249.6 - Proposition 65This service manual is intended for qualified service techni
4、cians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual.Improperly performed repairs can adversely affect the safety and reliab
5、ility of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.1. SAFETY PRECAUTIONS The following check should be performed for the continu
6、ed protection of the customer and service technician.LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the applianc
7、e (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120 V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA.ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE
8、OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER.2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded
9、by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics
10、and on the parts list in this Service Manual.The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is conti
11、nuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. LeakagecurrenttesterReading shou
12、ldnot be above0.5 mADeviceundertestTest allexposed metalsurfacesAlso test withplug reversed(Using AC adapterplug as required)EarthgroundAC Leakage Test(FOR USA MODEL ONLY)RadioFans.CN 收音机爱 好者资料库3PLX-100056785678ABCDEFCONTENTS SAFETY INFORMATION.21. SERVICE PRECAUTIONS.41.1 NOTES ON SOLDERING.41.2 NO
13、TES ON SERVICING.42. SPECIFICATIONS.53. BASIC ITEMS FOR SERVICE .63.1 CHECK POINTS AFTER SERVICING .63.2 JIGS LIST.63.3 PCB LOCATIONS.74. BLOCK DIAGRAM .84.1 OVERALL WIRING DIAGRAM .84.2 AUDIO SYSTEM BLOCK DIAGRAM.105. DIAGNOSIS .125.1 TROUBLESHOOTING.126. SERVICE MODE.147. DISASSEMBLY .158. EACH SE
14、TTING AND ADJUSTMENT.229. EXPLODED VIEWS AND PARTS LIST.249.1 PACKING SECTION.249.2 EXTERIOR SECTION .2610. SCHEMATIC DIAGRAM.2810.1 MAIN PCB, SEARCHLIGHT and SPEED PCB ASSYS .2810.2 D.D. MOTOR ASSY, SENSOR PCB and PHONO PCB ASSY.3010.3 STOROBOSCOPE, PLAY PCB and AC PCB ASSYS.3211. PCB CONNECTION DI
15、AGRAM.3411.1 MAIN PCB, SEARCHLIGHT and SPEED PCB ASSYS .3411.2 D.D. MOTOR ASSY, SENSOR PCB and PHONO PCB ASSY.3811.3 STOROBOSCOPE, PLAY PCB and and AC PCB ASSYS.4212. PCB PARTS LIST.434PLX-10001234ABCDEF12341. SERVICE PRECAUTIONS1.1 NOTES ON SOLDERING1.2 NOTES ON SERVICING For environmental protecti
16、on, lead-free solder is used on the printed circuit boards mounted in this unit. Be sure to use lead-free solder and a soldering iron that can meet specifications for use with lead-free solders for repairs accompanied by reworking of soldering. Compared with conventional eutectic solders, lead-free
17、solders have higher melting points, by approximately 40 C. Therefore, for lead-free soldering, the tip temperature of a soldering iron must be set to around 373 C in general, although the temperature depends on the heat capacity of the PC board on which reworking is required and the weight of the ti
18、p of the soldering iron.Do NOT use a soldering iron whose tip temperature cannot be controlled.Compared with eutectic solders, lead-free solders have higher bond strengths but slower wetting times and higher melting temperatures (hard to melt/easy to harden).The following lead-free solders are avail
19、able as service parts: Parts numbers of lead-free solder: GYP1006 1.0 in dia. GYP1007 0.6 in dia. GYP1008 0.3 in dia.For final-check playback after repair, a commercially available record and a cartridge are required.The details, see 3.2 JIGS LIST.5PLX-100056785678ABCDEF2. SPECIFICATIONSPower requir
20、ements.AC 110 V to 120 V or 220 V to 240 V, 50 Hz/60 HzPower consumption.9 WMain unit weight.13.1 kg (28.9 lb)Max. dimensions.453 mm (W) 159 mm (H) 353 mm (D)(17.8 in. (W) 6.3 in. (H) 13.9 in. (D)Tolerable operating temperature.+5 C to +35 C (+41 F to +95 F)Tolerable operating humidity.5 % to 85 % (
21、no condensation)Turntable partDrive method. Servo type direct driveMotor. 3-phase brushless DC motorBraking system. Electronic brakeRotation speed .33 1/3 rpm, 45 rpmRotation speed adjustment range. 8 %, 16 %, 50 %Wow and flutter. 0.1 % or less WRMS (JIS WTD)S/N ratio.70 dB (DIN-B)Turntable. Aluminu
22、m die-casting Diameter: 332 mmStarting torque.4.5 kgcm or moreStart time.0.3 seconds (at 33 1/3 rpm)Tone arm partArm type.Universal type S-shape tone arm,gimbal-supported type bearing structure, static balance typeEffective length.230 mmOverhang.15 mmTracking error.Within 2 32Arm height adjustment r
23、ange.6 mmStylus pressure variable range. 0 g to 4.0 g (1 scale 0.1 g)Proper cartridge weight.3.5 g to 13 g (single cartridge)When shell weight is used.3.5 g to 6.5 gWhen only balance weight is used.6.0 g to 10 gWhen sub weight is used.9.5 g to 13 g The specifications and design of this product are s
24、ubject to change without notice.Accessories Turntable (702-PNTT-075) Turntable sheet (705-DJ1900-078) Slip mat (612-PNTT-095) Slip sheet (505-PNTT-248) Dust cover (705-PLX1000-1583) Adapter for EP record (200-PNTT-211A) Balance weight (702-PNTT-076) Sub weight (200-PNTT-693) Headshell (703-PNTT-1411
25、) Shell Weight (200-ST100-268) Power Cord (LPSYXE8: 409-HDJ7100-055D-HA) (FUXECB: 409-HDJ7100-054D-HA) Audio Cable (408-PLX-140) Ground Wire (406-PLX-1288) Operating instructions (LPSYXE8: 502-PX1000B-3366) (FUXECB: 502-PX1000A-3365)6PLX-10001234ABCDEF12343. BASIC ITEMS FOR SERVICE3.1 CHECK POINTS A