Technics-RSDV250-tape-sm 维修电路原理图.pdf
《Technics-RSDV250-tape-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Technics-RSDV250-tape-sm 维修电路原理图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、http:/servis- Manual TOP NEXT AD0102028C2 Cassette Deck lRS-DV250 AR-2 Mechanism series Colour (S).Silver Type Area (E).Europe. 2001 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. TOP NEXT RadioFans.CN 收音机爱 好者资料库http:/servis
2、- Service Mode Function of Cassette Mechanism TOP PREVIOUS NEXT This unit is equipped with a service mode function of cassette mechanism, so that if the unit operates incorrectly, the fault displayed using an error code on the FL display of the Tuner/Amplifier (SA-EH770). The system control IC and F
3、Ldisplay are part of the Tuner/Amplifier so make sure the system has been connected properly before using this function. Use this function during maintenance to check faults of items below. 5.1 Cassette tape to be prepared 5.2 Selecting service mode 5.3 Deck 1 mechanism check 5.4 Deck 2 mechanism ch
4、eck 5.5 Exiting service mode TOP PREVIOUS NEXT 20. 10. 2004file:/C:Documents%20and%20SettingsAdminPlochaSCHMATAVIDEAPAN.RadioFans.CN 收音机爱 好者资料库http:/servis- Cassette tape to be prepared TOP PREVIOUS NEXT lMetal tape: Recorded music tape with only one erasure prevention tab intact./(use middle portio
5、n of tape) lNormal tape: /CrO2 tape: Recorded music tape with both erasure prevention tabs intact./(use middle portion of tape) TOP PREVIOUS NEXT http:/servis- Selecting service mode TOP PREVIOUS NEXT 1. Turn on the power to the unit. 2. Make sure that no tape is inserted in the cassette deck. (Serv
6、ice mode cannot be selected with a tape inserted in the cassette deck.) 3. Press the DOLBY NR button for about 2 seconds, and keep pressing it, also press the STOP button for about 2 seconds. Refer to Fig. 5-1. Fig. 5-1. TOP PREVIOUS NEXT 20. 10. 2004file:/C:Documents%20and%20SettingsAdminPlochaSCHM
7、ATAVIDEAPAN.http:/servis- Deck 1 mechanism check TOP PREVIOUS NEXT 1. Press the Deck 1/deck 2 select button to change the flashing Deck 2 indicator to Deck 1. Refer to Fig. 5-2. /(No change required if Deck 1 indicator already flashing.) 2. Press the Deck 1 cassette holder open button to open the De
8、ck 1 cassette holder. Refer to Fig. 5-2. 3. Insert a CrO2 tape into the Deck 1 and close the cassette holder. 4. Press the Fast forward button. Refer to Fig. 5-2. /(Tape fast forwards for about 2 seconds then stops.) 5. Press the PLAY button. Refer to Fig. 5-2. /(After TPS operation and check, the t
9、ape stops.) 6. Open the Deck 1 cassette holder and replace the tape with a normal tape. 7. Close the Deck 1 cassette holder. 8. Press the Record pause button. Refer to Fig. 5-2. /(No record operation.) 9. Press the STOP button. Refer to Fig. 5-2. A mechanism error code is displayed. Refer to Table 5
10、-1. Each time the STOP button is pressed, the fault items are displayed in sequence. Fig. 5-2. Table 5-1.FL display Symptom Cause H01 Cassette deck does not operate correctly. Faulty cassette deck mechanism mode detect switch (Deck 1: S951, Deck 2: S971), plunger and capstan motor. /(Check and repla
11、ce) H02 Unit does not record or the unit goes into recording mode even when the erasure prevention tabs have been removed from the cassette. Faulty erasure prevention tabs detect switch (S974, S975) or short-circuit. (Check and replace) H03 Tape does not play even when the tape deck play button is p
12、ressed. The motor operates when the tape deck play button is pressed even if cassette is loaded in the deck. Faulty tape detect switch (Deck 1: S952 Deck 2: S972) or short-circuit. (Check and replace) H06 Cassette deck does not detect CrO2 tape. Faulty CrO2 tape detect switch (Deck 1: S953, Deck 2:
13、S973)./(Check and replace) H07 Cassette deck does not detect Metal tape. Faulty Metal tape detect switch (S976). (Check and replace) F01 When the tape play button is pressed, tape advances only slightly and then stops. Reel pulse error (Faulty Hall IC). (Check and replace) F02 TPS (tape program sear
14、ch) does not work. Faulty TPS signal detection or faulty plunger control. /(Check and replace mechanism control IC) 20. 10. 2004file:/C:Documents%20and%20SettingsAdminPlochaSCHMATAVIDEAPAN.http:/servis- Deck 2 mechanism check TOP PREVIOUS NEXT 1. Press the Deck 1/deck 2 select button to change the f
15、lashing Deck 1 indicator to Deck 2. Refer to Fig. 5-3. 2. Press the Deck 2 cassette holder open button to open the Deck 2 cassette holder. Refer to Fig. 5-3. 3. Insert a metal tape into the Deck 2 with an intact erasure prevention tab on the right side. 4. Close the Deck 2 cassette holder. 5. Press
16、the Fast forward button. Refer to Fig. 5-3. /(Tape fast forwards for about 2 seconds then stops.) 6. Open the Deck 2 cassette holder and turn over the metal tape. (intact erasure prevention tab on the left side.) 7. Close the Deck 2 cassette holder. 8. Press the Rewind button. Refer to Fig. 5-3. /(T
17、ape rewinds for about 2 seconds then stops.) 9. Open the Deck 2 cassette holder and replace the metal tape with a CrO2 tape. 10. Close the Deck 2 cassette holder. 11. Press the PLAY button. Refer to Fig. 5-3. /(After TPS operation and check, the tape stops.) 12. Open the Deck 2 cassette holder and r
18、eplace the CrO2 tape with a normal tape. 13. Close the Deck 2 cassette holder. 14. Press the Record pause button. Refer to Fig. 5-3. /(No record operation.) 15. Press the STOP button. Refer to Fig. 5-3. A mechanism error code is displayed. Refer to Table 5-1. Each time the STOP button is pressed, th
19、e fault items are displayed in sequence. Fig. 5-3. 20. 10. 2004file:/C:Documents%20and%20SettingsAdminPlochaSCHMATAVIDEAPAN.http:/servis- Exiting service mode TOP PREVIOUS NEXT 1. Press the STOP button for more than 5 seconds (Diagnostic contents stored in memory for both Deck 1 and 2 are erased.) 2
20、. Remove the cassette tape from the cassette holder. 3. Turn off the unit. TOP PREVIOUS NEXT http:/servis- Head azimuth adjustment (Deck 1/2) TOP PREVIOUS NEXT 1. Connect the measuring instrument as shown in Fig. 13-1. 2. Replace azimuth screws for both forward and reverse directions after removing
21、the screw-locking bond left on the head base. (Supply part No. of azimuth screw: RHD17015 ) 3. Playback the azimuth adjustment portion (8 kHz, -20 dB) of test tape (QZZCFM). Adjust the azimuth screw until the outputs of the L/R ch are maximized. Refer to Fig. 13-2. Make sure that thedifference in th
22、e peak level between the left and right channels does not exceed 0.5 dB. 4. Perform the same adjustment in reverse playback mode. Check of the level difference forward and reverse directions. 5. Playback the playback gain adjustment portion (315 Hz, 0 dB) of test tape (QZZCFM). Check if level differ
23、ence between forward and reverse direction is within 1.5 dB. 6. After the adjustment, apply screw lock to the azimuth screw. Fig. 13-1. Fig. 13-2. TOP PREVIOUS NEXT 20. 10. 2004file:/C:Documents%20and%20SettingsAdminPlochaSCHMATAVIDEAPAN.http:/servis- Tape speed adjustment/(Deck 1/2) TOP PREVIOUS NE
24、XT Note: When connecting the unit to other system components for test, short the section between the test point TP604 and TP609 and turn on the entire system. (The unit is set to the TEST mode, and either Deck 1 or Deck 2 indicatorwill blink.) Normal speed (Standard value: 3000 45 Hz) 1. Connect the