Hitachi-DVP415U-cd-sm 维修电路原理图.pdf
《Hitachi-DVP415U-cd-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Hitachi-DVP415U-cd-sm 维修电路原理图.pdf(50页珍藏版)》请在收音机爱好者资料库上搜索。
1、TK No.9103ESPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENTDVD PLAYERSERVICE MANUAL2001MarchDigital Media Products Division, TokaiDV-P415U 1. Precautions 2. Product Specifications 3. Operating Instructions 4. Disassembly and Reassembly 5. Troubleshooting 6. Exploded Views 7. Replacemen
2、t Parts List 8. Block Diagrams 9. PCB Diagrams10. Wiring Diagram11. Schematic DiagramCONTENTSRadioFans.CN 收音机爱 好者资料库1-11. Precautions1-1 Safety Precautions1) Before returning an instrument to the customer,always make a safety check of the entireinstrument, including, but not limited to, thefollowing
3、 items:(1) Be sure that no built-in protective devices aredefective or have been defeated during servicing.(1)Protective shields are provided to protect boththe technician and the customer. Correctly replaceall missing protective shields, including anyremove for servicing convenience.(2)When reinsta
4、lling the chassis and/or other as-sembly in the cabinet, be sure to put back in placeall protective devices, including, but not limited to,nonmetallic control knobs, insulating fish papers,adjustment and compartment covers/shields, andisolation resistor/capacitor networks. Do notoperate this instrum
5、ent or permit it to be operatedwithout all protective devices correctly installedand functioning.(2) Be sure that there are no cabinet openingsthrough which adults or children might be able toinsert their fingers and contact a hazardousvoltage. Such openings include, but are not limitedto, excessive
6、ly wide cabinet ventilation slots, andan improperly fitted and/or incorrectly securedcabinet back cover.(3) Leakage Current Hot Check-With the instrumentcompletely reassembled, plug the AC line corddirectly into a 120V AC outlet. (Do not use aisolation transformer during this test.) Use aleakage cur
7、rent tester or a metering system thatcomplies with American National Standardsinstitute (ANSI) C101.1 Leakage Current forAppliances and Underwriters Laboratories (UL)1270 (40.7).With the instruments AC switch first inthe ON position and then in the OFF position,measure from a known earth ground (met
8、al waterpipe, conduit, etc.) to all exposed metal parts ofthe instrument (antennas, handle brackets, metalcabinets, screwheads, metallic overlays, controlshafts, etc.), especially any exposed metal partsthat offer an electrical return path to the chassis.Any current measured must not exceed 0.5mA.Re
9、verse the instrument power cord plug in theoutlet and repeat the test. See Fig. 1-1.Any measurements not within the limits specifiedherein indicate a potential shock hazard that mustbe eliminated before returning the instrument tothe customer.Fig. 1-1 AC Leakage Test(4) Insulation Resistance Test Co
10、ld Check-(1) Unplugthe power supply cord and connect a jumper wirebetween the two prongs of the plug. (2) Turn on thepower switch of the instrument. (3) Measure theresistance with an ohmmeter between thejumpered AC plug and all exposed metallic cabinetparts on the instrument, such as screwheads,ante
11、nna, control shafts, handle brackets, etc.When an exposed metallic part has a return pathto the chassis, the reading should be between 1and 5.2 megohm. When there is no return path tothe chassis, the reading must be infinite. If thereading is not within the limits specified, there isthe possibility
12、of a shock hazard, and theinstrument must be re-pared and rechecked beforeit is returned to the customer. See Fig. 1-2.Fig. 1-2 Insulation Resistance TestDEVICEUNDERTEST(READING SHOULDNOT BE ABOVE0.5mA)LEAKAGECURRENTTESTEREARTHGROUNDTEST ALLEXPOSED METERSURFACESALSO TEST WITHPLUG REVERSED(USING AC A
13、DAPTERPLUG AS REQUIRED)2-WIRE CORDAntennaTerminalExposedMelal PartohmohmmeterRadioFans.CN 收音机爱 好者资料库Precautions1-22) Read and comply with all caution and safety re-lated notes non or inside the cabinet, or on thechassis.3) Design Alteration Warning-Do not alter of add tothe mechanical or electrical
14、design of thisinstrument. Design alterations and additions,including but not limited to, circuit modifications andthe addition of items such as auxiliary audio outputconnections, might alter the safety characteristicsof this instrument and create a hazard to the user.Any design alterations or additi
15、ons will make you,the service, responsible for personal injury orproperty damage resulting therefrom.4) Observe original lead dress. Take extra care toassure correct lead dress in the following areas:(1) near sharp edges, (2) near thermally hot parts(be sure that leads and components do not touchthe
16、rmally hot parts), (3) the AC supply, (4) highvoltage, and (5) antenna wiring. Always inspect inall areas for pinched, out-of-place, or frayed wiring,Do not change spacing between a component andthe printed-circuit board. Check the AC power cordfor damage.5) Components, parts, and/or wiring that app
17、ear tohave overheated or that are otherwise damagedshould be replaced with components, parts and/ orwiring that meet original specifications.Additionally, determine the cause of overheatingand/or damage and, if necessary, take correctiveaction to remove any potential safety hazard.6) Product Safety
18、Notice-Some electrical andmechanical parts have special safety-relatedcharacteristics which are often not evident fromvisual inspection, nor can the protection they givenecessarily be obtained by replacing them withcomponents rated for higher voltage, wattage, etc.Parts that have special safety char
19、acteristics areidentified by shading, an ( )or a ( )onschematics and parts lists. Use of a substitutereplacement that does not have the same safetycharacteristics as the recommended replacementpart might created shock, fire and/or other hazards.Product safety is under review continuously andnew inst
20、ructions are issued whenever appropriate.Precautions1-31-2 Servicing PrecautionsCAUTION : Before servicing Instruments coveredby this service manual and its supplements, read andfollow the Safety Precautions section of this manual.Note : If unforseen circument create conflict betweenthe following se
21、rvicing precautions and any of thesafety precautions, always follow the safetyprecautions. Remember: Safety First.1-2-1 General Servicing Precautions(1) a. Always unplug the instruments AC power cordfrom the AC power source before (1) re-movingor reinstalling any component, circuit board,module or a
22、ny other instrument assembly, (2)disconnecting any instrument electrical plug orother electrical connection, (3) connecting a testsubstitute in parallel with an electrolyticcapacitor in the instrument.b. Do not defeat any plug/socket B+ voltageinterlocks with which instruments covered by thisservice
23、 manual might be equipped.c. Do not apply AC power to this instrument and/or any of its electrical assemblies unless allsolid-state device heat sinks are correctly in-stalled.d. Always connect a test instruments ground leadto the instrument chassis ground beforeconnecting the test instrument positiv
24、e lead.Always remove the test instrument ground leadlast.Note : Refer to the Safety Precautions section groundlead last.(2) The service precautions are indicated or printedon the cabinet, chassis or components. Whenservicing, follow the printed or indicated serviceprecautions and service materials.(
25、3) The components used in the unit have a specifiedflame resistance and dielectric strength.When replacing components, use componentswhich have the same ratings. Components i-entified by shading, by( ) or by ( ) in the circuitdiagram are important for safety or for thecharacteristics of the unit. Al
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hitachi-DVP415U-cd-sm 维修电路原理图 Hitachi DVP415U cd sm 维修 电路 原理图