1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB0532003/9MICRO COMPONENT SYSTEMMB05320039UX-H35TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC
2、SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74ADJUSTMENT
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23MI
4、CRO COMPONENT SYSTEMArea SuffixA - AustraliaRadioFans.CN 收音机爱 好者资料库1-2 (No.MB053)SPECIFICATIONAmplifierOutput Power20 W (10 W + 10 W) at 4 (10% THD)Audio input sensitivity/Impedance (at 1 kHz) AUX 500 mV/48.75 kSpeakers/Impedance4 TunerFM tuning range87.50 MHz - 108.00 MHzAM tuning range522 kHz - 1
5、629 kHzCD playerDynamic range85 dBSignal-to-noise ratio90 dBWow and flutterImmeasurableCassette deck Frequency response Normal (type I)50 Hz - 15 000 HzWow and flutter0.15% (WRMS)SpeakerSpeaker units Full range8.0 cm cone 1Impedance4 Dimensions (approx.)135 mm 203 mm 190 mm (W/H/D)Mass (approx.)1.7
6、kg eachGeneralPower requirementAC IN240 V , 50 HzDC IN12 V, 4 APower consumption35 W (at operation)3.0 W (on standby)Dimensions (approx.)412 mm 208 mm 275 mm (W/H/D)Mass (approx.)6.5 kgRadioFans.CN 收音机爱 好者资料库(No.MB053)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contai
7、ns special hardware andmany circuits and components specially for safety purposes.For continued protection, no changes should be made to theoriginal design unless authorized in writing by the man-ufacturer. Replacement parts must be identical to thoseused in the original circuits. Services should be
8、 per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibil
9、ity for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-
10、ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these special safetycharacteristics are identified in the Parts List of Service Manu-al. Electrical components having such features are iden-tified by shading on the schematics and by () on theParts List
11、 in the Service Manual. The use of a substitute re-placement which does not have the same safety character-istics as the recommended replacement parts shown in theParts List of Service Manual may create shock, fire, or oth-er hazards.(4) The leads in the products are routed and dressed with ties,cla
12、mps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have be
13、en returned to normal, after reassembling.(5) Leakage shock hazard testing)After reassembling the product, always perform an isolationcheck on the exposed metal parts of the product (antennaterminals, knobs, metal cabinet, screw heads, headphonejack, control shafts, etc.) to be sure the product is s
14、afe tooperate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part
15、having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use an ACvoltmeter having, 1,000 ohms per volt or more sensitivity inthe following manner. Connect a 1,50
16、0 ohm 10W resistorparalleled by a 0.15 F AC-type capacitor between anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metal part,particularly any exposed metal part having a return path toth
17、e chassis, and measure the AC voltage across the resistor.Now, reverse the plug in the AC outlet and repeat eachmeasurement. Voltage measured any must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet interna
18、tional safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains volta
19、ge selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on
20、the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of the same typeand rating as specified by the
21、 manufacturer. (Except the JC version)1-4 (No.MB053)1.5Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when pe
22、rforming repairs.1.5.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbenchGround the
23、 workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing thetraverse unit (optical pickup) on it.(2) Ground yourselfUse an anti-static wrist strap to release any static electricity built up in your body. (3) Handling the optical pickup In order to
24、 maintain quality during transport and before installation, both sides of the laser diode on the replacement opticalpickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) Do not use a tester to check the condition of the laser diode in the o
25、ptical pickup. The testers internal power source can easilydestroy the laser diode. 1.6 Handling the traverse unit (optical pickup)(1) Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. (2) Cut off the shorted part of the flexible cable using nipp
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-UXH35-cs-sm 维修电路原理图 JVC UXH35 cs sm 维修 电路 原理图