1、UX-M3RNo.21059Jan. 2002COPYRIGHT 2002 VICTOR COMPANY OF JAPAN, LTD.SERVICE MANUALContentsSafety precautionsPreventing static electricityImportant for laser productsDisassembly methodAdjustment methodFlow of functional operation until TOC read1-21-31-41-51-141-171-181-181-191-201-29Maintenance of las
2、er pickupReplacement of laser pickupTrouble shootingDescription of major ICsWiring connectionsUX-M3R Area suffixB - U.K.E - Continental EuropeEN - Northern EuropeEV - Eastern EuropeSP-UXM3CA-UXM3RSP-UXM3DISPLAYMODEPHONESPROGRAMRECSTOP/CLEARPLAY/PAUSEPRE EQ/HBSVOLUMEREPEATSEARCH/TUNINGRANDOM CDTUNERT
3、APEBANDM I C R O C O M P O N E N T S Y S T E M U X - M 3 RFULL LOGIC DECKCD SYNCHRO RECORDINGTIMERON/OFFSETREMAIN/RDS MODEEJECTINTRO/RDSSEARCHPRESETOPEN/CLOSESTANDBY/ONCD/RANDOMTAPEDISPLAYMODEPROGRAMRECSLEEPPRE UPTIMERBEAT CUTSTANDBY/ON+VOLUMETUNER/BANDREPEAT/PRE DOWNINTRO/RDS SEARCHREMAIN/RDS MODER
4、M-SUXM3R REMOTE CONTROLMUTINGPRE EQ/HBSMICRO COMPONENT SYSTEMRadioFans.CN 收音机爱 好者资料库UX-M3R1-21. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless auth
5、orized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be
6、 made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. T
7、hese characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List
8、 of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Par
9、ts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and f
10、ire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5. Leakage currnet check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation
11、check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord di
12、rectly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate
13、check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC
14、 voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Vo
15、ltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs
16、 must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1
17、000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In regard with component parts appearing on the silk-screen printed side (parts
18、side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. (This regulation does not correspond to J and C version.)RadioFans.CN 收音机爱 好者资料库UX-M3R1-3Short landCD pickup unitConnectorCo
19、nductive material (conductive sheet) or iron plate(caption)Anti-static wrist strap5. Attention when traverse unit is decomposed*Please refer to Disassembly method in the text for the CD pickup unit. Apply solder to the short land before the card wire is disconnected from the connector on the CD pick
20、up unit. (If the card wire is disconnected without applying solder, the CDpickup may be destroyed by static electricity.) In the assembly, be sure to remove solder from the short land after connecting the card wire.Electrostatic discharge (ESD), which occurs when static electricity stored in the bod
21、y, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.Preventing static electricity1. Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (las
22、er diode) in devices such as CD players.Be careful to use proper grounding in the area where repairs are being performed. 2. About the earth processing for the destruction prevention by static electricityGround the workbench by laying conductive material (such as a conductive sheet) or an iron plate
23、 over it before placing the traverse unit (optical pickup) on it.2-1 Ground the workbench2-2 Ground yourselfUse an anti-static wrist strap to release any static electricity built up in your body. In order to maintain quality during transport and before installation, both sides of the laser diode on
24、the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode. 3. Handl
25、ing the optical pickup1.2. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit.Remove solder of the short land on the card wire after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove the anti