JVC-UXA10-cs-sm 维修电路原理图.pdf
《JVC-UXA10-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-UXA10-cs-sm 维修电路原理图.pdf(123页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALMICRO COMPONENT MD SYSTEMNo.22011Jan. 2003COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.UX-A10DVDUX-A10DVDContentsSafety precautionPreventing static electricityDisassembly methodAdjustment methodMaintenance of MD pickup1-21-31-41-391-47Procedures of changing the MD pickupMaintenance of D
2、VD pickupProcedures of changing the DVD pickupDescription of major ICs1-471-481-481-4988Area suffixUB - Hong KongRadioFans.CN 收音机爱 好者资料库1-2UX-A10DVD1. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no ch
3、anges should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be ma
4、de. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the
5、products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special
6、safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristic
7、s as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or
8、 sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5. Leakage currnet check (Electrical shock hazard testing)After
9、re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation
10、 transformer during this check.Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leaka
11、ge current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed
12、metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse th
13、e plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensur
14、e that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace thi
15、s probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In regard with component
16、parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. (This regulation does not correspond to J and C version.)RadioFans.CN
17、 收音机爱 好者资料库1-3UX-A10DVDCN101Sorting round pointCN101Flexible wireServo control boardDVD mechanism assemblyMD mechanism assemblyCN321PickupSolderingPreventing static electricity1.Grounding to prevent damage by static electricity Electrostatic discharge (ESD), which occurs when static electricity stor
18、ed in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.2.About the earth processing for the destruction prevention by static electricity Static electricity in the work area can destroy the optic
19、al pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. 2-1 Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit
20、(optical pickup) on it.2-2 Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup1. In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup a
21、re shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode.Attention when traverse unit is decomp
22、osed1.Solder is put up before the card wire is removed from connector on the CD substrate as shown in Figure. (When the wire is removed without putting up solder, the pick-up assembly might destroy.) 2.Please remove solder after connecting the card wire with when you install picking up in the substr
23、ate.*Please refer to Disassembly method in the text for pick-up and how to detach the substrate. (caption)Anti-static wrist strapConductive material (conductive sheet) or iron plate1-4UX-A10DVDRemove the six screws A on the back of the body.Remove the screw B on each side of the body.Detach the rear
24、 side of the metal cover upward while pulling the lower sides outward.1.2.3.Disassembly methodRemoving the metal cover (See Fig.13)Fig.1Fig.2Fig.3AAAMetal coverMetal coverMetal coverBB1-5UX-A10DVDPrior to performing the following procedure, remove the metal cover.Remove the three screws C attaching
25、the DVD mechanism assembly on top of the body.Disconnect connector CN502 and CN503 on the DVD servo board upward at the bottom of the DVD mechanism assembly.Bring up the DVD mechanism assembly and remove backward.1.2.Removing the DVD mechanism assembly (See Fig.46)Fig.4Fig.5Fig.6CCCDVD mechanism ass