JVC-TDW271-tape-sm 维修电路原理图.pdf
《JVC-TDW271-tape-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-TDW271-tape-sm 维修电路原理图.pdf(43页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB0612004/1DOUBLE CASSETTE DECKMB061200312TD-W271TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC
2、SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54ADJUSTMENT
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-135TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1954
4、6372819MINMAXINPUT LEVELCOUNTER RESETCOUNTER RESETSTANDBYSTANDBY/ON ON OFFPLAYPHONESPOWERREVERSE MODEDOUBLE CASSETTE DECKREC / REC MUTE PAUSEA B SYNCHRO DUBBINGDOLBY B-C NR HX PROPLAYREC/PLAYBACKBAUTO REVERSE3MOTOR SILENT MECHANISMAUTO REVERSE3MOTOR SILENT MECHANISMPLAYBACKADOLBY NRB OFF CAUTO TAPE
5、SELECTOR / CONTINUOUS PLAYNORM SPEEDHIGH SPEEDUF - ChinaU - Other AreasArea SuffixRadioFans.CN 收音机爱 好者资料库1-2 (No.MB061)SPECIFICATIONDesign and specifications are subject to change without notice.TypeDouble cassette deckTrack system4-track, 2-channelTape speed4.8 cm/sec (1-7/8 inch/sec) (Normal)9.5 c
6、m/sec (3-3/4 inch/sec) (High)Frequency response(-20 dB recording)Type IV tape20-17000Hz30-16000 Hz (3dB)Type II tape20-16000 Hz30-15000 Hz (3dB)Type I tape20-16000 Hz30-15000 Hz (3dB)S/N ratio58 dB (S = 315 Hz, k3 = 3%, N = A-weighted, Type IV tape)The S/N is improved by about 15 dB at 500 Hz and by
7、 max.20 dB at 1kHz 10 kHz with Dolby C NR on and improved by 5 dBat 1 kHz and by 10 dB at above 5 k Hz with DOLBY B BR on.Improvement of MOL4 dB at 10 kHz with Dolby C NR on.Wow and flutter0.08% (WRMS), 0.2% (DIN/IEC)Channel separation10 dB (1 kHz)Crosstalk60 dB (1 kHz)Harmonic distortionk3; 0.8% (T
8、ype IV tape, 315 Hz, 0 VU)HeadsDeck AMETAPARM head for playback 1Deck BMETAPARM head for recording/playback,2-gap ferrite head for erasure; combination head 1MotorsElectric govemed DC motor for capstan 1DC motor for reel 1DC motor for mechanism drive 1 (For both decks A and B)Fast forward/rewind tim
9、eApprox. 110 sec. with C-60 cassetteInput terminalsLINE IN ( 1 circuit)Input sensitivity80 mV (0 VU)Input impeadance50 kOutput terminalsLINE OUT ( 1 circuit) Output level300 mV (0 VU)Output impeadance5 kPHONES 1Output level0.3 mW/8 (0 VU)Matching impedance8 - 1 k Other terminalsCOMPU LINK-3/SYNCRO 2
10、Power requirementAC 220 V, 50 HzPower consumptionWith power on 17 WWith power standby 4.0 WDimensions435 139 331 mmMass5.0 kgRadioFans.CN 收音机爱 好者资料库(No.MB061)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially
11、 for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of th
12、e design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom
13、.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age
14、, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement whi
15、ch does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts
16、, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazar
17、d testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a l
18、ine isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth groun
19、d. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-
20、posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse
21、the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repaire
22、r to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs f
23、ormed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts t
24、hat areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good
25、earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB061)SECTION 2SPECIFIC SERVICE INSTRUCTIONSThis service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.(No.MB061)1-5SECTION 3DISASSEMBLY3.1Enclosure s