JVC-UXG30-cs-sm 维修电路原理图.pdf
《JVC-UXG30-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-UXG30-cs-sm 维修电路原理图.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5362006/6MICRO COMPONENT SYSTEMMB53620066UX-G35US,UX-G35UB,UX-G33A,UX-G33US,UX-G33UB,UX-G33UW,UX-G30US,UX-G30UB,UX-G30UWLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTI
2、ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73DISASSE
3、MBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . 1-215TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22CA-UXG35SP-UXG35SP-UXG35CA-UXG33SP-UXG33SP-UXG33CA-UXG30SP-UXG30SP-UXG30RadioFans.CN 收音机爱 好者资料库1-2 (No.MB536)SPECIFICATIONDesign and specific
5、ations are subject to change without notice.Amplifier sectionOutput Power60 W (30 W + 30 W) at 6 (10% THD)Speakers/Impedance6 - 16 Audio InputAUX500 mV/50 k (at AUX LVL 1)250 mV/50 k (at AUX LVL 2)125 mV/50 k (at AUX LVL 3)Tuner sectionFM tuning range531 kHz - 1 710 kHz (at 9 kHz intervals)AM tuning
6、 range530 kHz - 1 710 kHz (at 10 kHz intervals)CD player sectionDynamic range88 dBSignal-to-noise ratio93 dBWow and flutterImmeasurableCassette deck sectionFrequency responseNormal (type I): 50 Hz - 14 000 HzWow and flutter0.15% (WRMS)SpeakersSpeaker units10 cm cone 1 + 1.5 cm dome 1Impedance6 Dimen
7、sions (approx.)140 mm 231 mm 195 mm (W/H/D)Mass (approx.)1.7 kg eachGeneralPower requirementHong Kong AC 220 V , 50 HzAustraliaAC 240 V , 50 HzotherAC 110 V/AC 127 V/AC 220 V/AC 230 V - 240 V , 50 Hz/60 Hz(adjustable with the voltage selector)Power consumptionHong Kong 50 W (at operation)9.5 W (on s
8、tandby/display on)1.1 W (on standby/display off)Australia50 W (at operation)10 W (on standby/display on)1.3 W (on standby/display off)other60 W (at operation)14.8 W (on standby/display on)3.8 W (on standby/display off)Dimensions (approx.)165 mm 231 mm 328 mm (W/H/D)Mass (approx.)4.5 kgRadioFans.CN 收
9、音机爱 好者资料库(No.MB536)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufac
10、turer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or
11、additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not
12、evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical com
13、ponents having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create
14、shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the
15、 original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals,
16、knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the
17、leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anA
18、C voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connectio
19、n to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC
20、(r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is es
21、sential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair
22、 of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When
23、 replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (N
24、o.MB536)1.5 Safety Precautions (U.K only)(1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For con-tinued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replace-men
25、t parts must be identical to those used in the original circuits.(2) Any unauthorised design alterations or additions will void the manufacturers guarantee; furthermore the manufacturer cannotaccept responsibility for personal injury or property damage resulting therefrom.(3) Essential safety critic
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-UXG30-cs-sm 维修电路原理图 JVC UXG30 cs sm 维修 电路 原理图