JVC-UXQD9S-cs-sm 维修电路原理图.pdf
《JVC-UXQD9S-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-UXQD9S-cs-sm 维修电路原理图.pdf(73页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB3382004/12MICRO COMPONENT SYSTEMMB338200412UX-QD9STABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIF
2、IC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74ADJUSTM
3、ENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-285TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
4、2(CA-UXQD9S)(SP-UXQD9S)(SP-UXQD9S)Area suffixA - AustraliaUS - SingaporeUN - AseanRadioFans.CN 收音机爱 好者资料库1-2 (No.MB338)SPECIFICATIONDVD receiver (CA-UXQD9S)Speaker (SP-UXQD9S)Micro component system (UX-QD9S) U.S. and foreign patents licensed from Dolby Laboratories. Design and specifications are sub
5、ject to change without notice.AmplifierOutput power20 W + 20 W at 4 (10% THD)Input terminalsAnalogAUX1,500 mV/47 k:LEVEL1250 mV/47 k:LEVEL2Output terminalsAnalogSpeaker1, 20 W/4 , Impedance 4 - 16 Headphone (1), 25 mW/32 , Impedance 16 - 1 kDigitalDVD/CD optical input 1-23 dBm to -15 dBm (Optical sq
6、uare terminal)OtherAV COMPU LINK 2 ( 3.5)TunerFrequencyFM87.50 MHz - 108.00 MHzAM531 kHz - 1 710 kHz (9 kHz spacing)530 kHz - 1 710 kHz (10 kHz spacing)DVD playerPlayable discsDVD VIDEO, DVD AUDIO, CD, VCD, SVCD, CD-R/CDRW (CD, VCD, SVCD, MP3/ WMA/JPEG format), DVD-R/ DVD-RW (video format)Cassette d
7、eck Frequency response Normal (type I)60 Hz - 14 000 HzWow and flutter 0.15% (WRMS)GeneralPower requirementAC 240 V , 50/60 Hz (UN,US only)AC 240 V , 50 Hz (A only)Power consumption70 W (at operation) 1.3 W (on standby)Dimensions165 mm (W) 200 mm (H) 355 mm (D)Mass (approx.)4.6 kgSystem3-way bass re
8、flex type, Magnetically shielded typeSpeakersWoofer10 cm 1Midrange4 cm 1Tweeter1.5 cm 1Power handling capacity20 WImpedance4 Frequency range55 Hz - 40 kHzSound pressure level85 dB/WmDimensions140 mm (W) 231 mm (H) 204.5 mm (D)Mass (approx.)2.2 kg (1 unit)GeneralDimensions445 mm (W) 231 mm (H) 355 mm
9、 (D)Mass (approx.)9.0 kgRadioFans.CN 收音机爱 好者资料库(No.MB338)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unle
10、ss authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldn
11、ot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics.
12、 These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts L
13、ist of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Pa
14、rts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and fir
15、ehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal part
16、s of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using
17、 aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cor
18、d directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC
19、voltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (
20、r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the
21、 relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such b
22、urrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the ma
23、rk nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more se
24、nsitivity)1500 10W0.15 F AC TYPE1-4 (No.MB338)1.5Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laserdiode in the traverse unit (optical pickup). Take care to prevent this when performin
25、g repairs.1.5.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as laser products. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbenchGround the wo
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-UXQD9S-cs-sm 维修电路原理图 JVC UXQD9S cs sm 维修 电路 原理图