JVC-MXDK15-cs-sm 维修电路原理图.pdf
《JVC-MXDK15-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXDK15-cs-sm 维修电路原理图.pdf(67页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5152006/6COMPACT COMPONENT SYSTEMMB51520066MX-DK1US,MX-DK1UW,MX-DK1UG,MX-DK1UN,MX-DK3US,MX-DK3UW,MX-DK3UG,MX-DK3UN,MX-DK15UNLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PREC
2、AUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73DIS
3、ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . 1-195TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21CA-MXDK3SP-MXDK3FSP-MXDK3FCA-MXDK1SP-MXDK1FSP-MXDK1FCA-MXDK15SP-MXDK15FSP-MXDK15FSP-MXDK3WRadioFans.CN 收音机爱 好者资料库1-2 (No.MB515)SPECIFICAT
5、IONAmplifier sectionOutput PowerCA-MXDK1/CA-MXDK1590 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 10% total harmonic distortion.CA-MXDK3MAIN SPEAKERS100 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 10% total harmonic distortion.SUBWOOFERS100 W per channel, m
6、in. RMS, driven into 6 at 63 Hz with no more than 10% total harmonic distortion.Digital outputOPTICAL DIGITAL OUTPUT-21 dBm to -15 dBm (660 nm 30 nm)Audio input sensitivity/Impedance*1AUX400 mV/47 k MIC 1/23.0 mV/50 k VIDEO OUTColor systemNTSC/PAL selectableVIDEO (composite)1 V(p-p)/75S-VIDEOY (lumi
7、nance)1 V(p-p)/75 C (chrominance, burst) 0.286 V(p-p)/75 COMPONENT(Interlace/Progressive: CA-MXDK5 only)(Y)1 V(p-p)/75 (PB/PR)0.7 V(p-p)/75 Speaker Terminals6 - 16 (Main speakers)6 - 16 (Subwoofers)Tuner sectionFM tuning range87.50 MHz - 108.00 MHzAM (MW) tuning range531 kHz - 1 710 kHz (at 9 kHz)53
8、0 kHz - 1 710 kHz (at 10 kHz)531 kHz - 1 602 kHz (at 9 kHz) (For Saudi Arabia only)530 kHz - 1 600 kHz (at 10 kHz)Disc player sectionPlayable discDVD Video/DVD Audio*2/CD/VCD/SVCDCD-R/-RW/-ROM (CD/VCD/SVCD/MP3/WMA/MPEG-1/MPEG-2/ASF*2/JPEG/DivX*2 format)DVD-R/-RW (DVD Video/DVD Video Recording (VR)/M
9、P3/WMA/MPEG-1/MPEG-2/ASF*2/JPEG/DivX*2 for-mat)+R/+RW (DVD Video format)Dynamic range90 dBHorizontal resolution500 linesWow and flutterImmeasurableCassette deck section Frequency response Normal (type I)50 Hz - 14 000 HzWow and flutter0.15% (WRMS)GeneralPower requirementAC 110 V / AC 127 V / AC 220
10、V / AC 230 V - AC 240 V , (adjustable with the voltage selector), 50 Hz / 60 HzPower consumption at operation160 W (CA-MXDK3)95 W (CA-MXDK1/ CA-MXDK15)on standby20 W (CA-MXDK3)17 W (CA-MXDK1/ CA-MXDK15)Dimensions (approx.)265 mm 337 mm 370 mm (W/H/D)Mass (approx.)CA-MXDK5/CA-MXDK38.4 kgCA-MXDK1/CA-M
11、XDK157.9 kgRadioFans.CN 收音机爱 好者资料库(No.MB515)1-3*1: Measured at 1 kHz, with tape recording signal 400 mV)*2: CA-MXDK5 onlyDesign and specifications are subject to change without notice.Speaker section(except for MX-DK5)Main speakers(SP-MXDK3F/SP-MXDK1F/SP-MXDK15F)Type3-Way 3-Speaker Bass Reflex Type
12、(Magnetically-Shielded Type)SpeakersWoofer16 cm cone 1Midrange5 cm cone 1Tweeter2 cm dome 1Power handling capacity100 W (SP-MXDK3F)80 W (SP-MXDK1F/SP-MXDK15F)Impedance6 Frequency range45 Hz - 20 000 HzSound pressure level85 dB/WmDimensions (approx.)215 mm 337 mm 259 mm (W/H/D)Mass (approx.)3.7 kg ea
13、chSubwoofer(SP-MXDK3W)(only for MX-DK3)Type1-Way Bass Reflex Type (Magnetically-Shielded Type)Speaker16 cm cone 1Power handling capacity100 WImpedance6 Dimensions (approx.)215 mm 337 mm 259 mm (W/H/D)Mass (approx.)3.5 kg1-4 (No.MB515)SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this pr
14、oduct contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Servic
15、es should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of
16、 responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obt
17、ained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe
18、 Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with t
19、ies,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they
20、have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the p
21、roductis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed m
22、etal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a
23、 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to
24、the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet interna
25、tional safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains volta
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-MXDK15-cs-sm 维修电路原理图 JVC MXDK15 cs sm 维修 电路 原理图