JVC-RCST3-cs-sch 维修电路原理图.pdf
《JVC-RCST3-cs-sch 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RCST3-cs-sch 维修电路原理图.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCD PORTABLE SYSTEMNo.MB0632003/11COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.RC-ST3SLContentsArea SuffixB - U.K.E -Contnental EuropeEN - Northern EuropeEV - Eastern EuropeSpecification -1-2Safety Precautions -1-3Preventing static electricity - 1-5Block Diagram - 1-6Schematic Diagrams -
2、 1-8TUNERPROGRAMFM MODEHBSEQRANDOMVOLINTROPRESET/REPEATTAPECDSTANDBYSEARCH UPSEARCH DOWNREMOTESENSORPLAY/PAUSESTOPRANDOMINTRORC-ST3CD PORTABLE SYSTEMRadioFans.CN 收音机爱 好者资料库SERVICE POLICYNo service parts are available for this model.Exchange only.Revised 28/9/2004 Service Policy added1-2Compact disc
3、playerSignal detection system Non-contact optical pickup(semiconductor laser)Number of channels2 channels (stereo)Frequency response20 Hz - 20 000 HzSignal-to-noise ratio90 dBWow and flutterLess than measurable levelTunerFM frequency range87.50 MHz - 108.00 MHzAM frequency range522 kHz - 1 629 kHzAn
4、tennasTelescopic antenna for FMFerrite core antenna for AMCassette deckTrack system4-track 2-channel stereoMotorElectronic governor DCmotor for capstanHeadsHard Permalloy head forrecording/playbackMagnetic head for erasureFrequency response80 Hz - 12 500 HzWow and flutter0.15% (WRMS)Fast-winding tim
5、eApprox. 120 sec.(C-60 cassette)GeneralSpeakers10 cm 2Power output2 W per channel, min. RMS,driven into 8 &! at 1 kHz,with no more than 10% totalharmonic distortion(IEC 268-3)Output terminalPHONES 1, output level0 mW - 20 mW/32 ohm,matching impedance: 16ohm 32 ohm Power supplyAC 230 V , 50 HzDC 12 V
6、 (batteries R20P(SUM-1)/D (13F) 8)Power consumption19 W (operation mode)3.2 W (standby mode)Dimensions440 mm (W) 168 mm (H) 241 mm (D)MassApprox. 3.1 kg(without batteries)SpecificationRadioFans.CN 收音机爱 好者资料库1-31. This design of this product contains special hardware and many circuits and components
7、specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterati
8、ons of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resul
9、ting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher volt
10、age, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute
11、replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separate
12、d from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5.
13、 Leakage currnet check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate
14、without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a retur
15、n path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resisto
16、r paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, a
17、nd meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standa
18、rds.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provid
- 配套讲稿: