JVC-MXG65V-cs-sm 维修电路原理图.pdf
《JVC-MXG65V-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXG65V-cs-sm 维修电路原理图.pdf(89页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOMPACT COMPONENT SYSTEM?No.20995Jul. 2001COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.MX-G68VMX-G65VMX-G68V/MX-G65VArea Suffix USSingaporeSafety precautionsPreventing static electricityImportant for laser productsDisassembly methodWiring connection Adjustment method1-21-31-41-51-18?1-1
2、9Flow of functional operation until TOC readMaintenance of laser pickupReplacement of laser pickupTroubleshootingDescription of major ICs 1-231-241-241-251-3352ContentsCA-MXG68VCA-MXG65VCANCEL/DEMOPRESETPLAY & EXCHANGESTANDBY/ONSTANDBYDISC CHANGESOUNDMODESUBWOOFERLEVELCD-R/RW PLAYBACKCOMPACT COMPONE
3、NT SYSTEMMX-G65VCLOCK/TIMERDISPLAYPHONESREPEATPROGRAMREC START/STOPCDREC STARTDUBBINGTAPE ATUNINGSETTAPE BRANDOMEJECTPLAYFULL - LOGIC CONTROLAEJECTREC/PLAYCD SYNCHRO RECORDINGBPREVNEXTRETURNPBCVCD NUMBERCOMPACTDIGITAL VIDEOVIDEO CDSELECTDISC SKIPVOLUMEVOLUME+RMSMXG65VU REMOTE CONTROLSTANDBY/ON123456
4、78910+10KEY CONTROLSUBWOOFERLEVELSOUNDMODEFM MODE/TAPE A/BFADE MUTINGFM/AMCD TAPE KARAOKEECHOPREV.NEXTRETURNSLEEPON SCREENV.INTROHIGHLIGHTSLOWAUX STILLSELECTCA-MXG65VSP-MXG65VSP-MXG65VVIDEO CDPlayBackControlModelColorUXSaudi ArabiaSilverShanpagne-goldRadioFans.CN 收音机爱 好者资料库MX-G68V/MX-G65V1-21. This
5、design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the origi
6、nal circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further reli
7、eve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by
8、them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schem
9、atics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are r
10、outed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it
11、should be confirmed that they have been returned to normal, after re-assembling.5. Leakage current check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads
12、, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each expo
13、sed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms
14、 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed meta
15、l part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. Thi
16、s equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critica
17、l components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left ove
18、r on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode
19、 ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the J&C version)RadioFans.CN 收音机爱 好者资料库MX-G68V/MX-G65V1-3Preventing static electricity1. Grounding to prevent
20、 damage by static electricity Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.2. About the earth processing for the
21、 destruction prevention by static electricity In the equipment which uses optical pick-up (laser diode), optical pick-up is destroyed by the static electricity of the work environment.Be careful to use proper grounding in the area where repairs are being performed. 2-1 Ground the workbench Ground th
22、e workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it.2-2 Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup1. In orde
23、r to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)2. Do not use a tester to check the condition of the laser diode i
24、n the optical pickup. The testers internal power source can easily destroy the laser diode. 4. Handling the traverse unit (optical pickup)1. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. 2. Cut off the shorted part of the flexible cable using
25、 nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long a time when attaching it to the connector. 3. Handle the flexible cable carefully as i