JVC-HXC6-cs-sm 维修电路原理图.pdf
《JVC-HXC6-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-HXC6-cs-sm 维修电路原理图.pdf(51页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB3662005/6COMPACT COMPONENT SYSYTEMMB36620056HX-C6Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-215TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21CA-HXC6SP-HXC6SP-HXC6Area suffixJ - U.S.A.RadioFans.CN 收音机爱 好者资料库1-2 (No.MB366)SPECIFICATIONAmplifier section-CA-HXC6Speaker section-SP-HXC6Design and specifications are subject to change without notice.Output Po
5、werSUB WOOFER170 W per channel, min. RMS, driven into 6 at 63 Hz with no more than10% total harmonic distortion.MAIN SPEAKER80 W per channel, min. RMS, driven into 4 at 1 kHz with no more than10% total harmonic distortion.Audio input sensitivity/impedanceAUX400 mV/47 kUSBUSB Version 1.1Speakers/impe
6、danceSUB WOOFER6 - 16 MAIN SPEAKER4 - 8 TunerFM tuning range87.5 MHz - 108.0 MHzAM tuning range530 kHz - 1 710 kHzCD playerCD capacity5 discsDynamic range87 dBSignal-to-noise ratio90 dBWow and flutterImmeasurableMP3 recording formatMPEG 1/2 Audio Layer 3Max. Bit rate320 kbpsGeneralPower requirementA
7、C 120 V , 60 HzPower consumption90 W/110 VA (at operation)11 W (on standby; with power saving off-Normal mode)1.2 W (on standby; with power saving on-Eco mode)Dimensions (W/H/D) (approx.)175 mm 373 mm 389 mm (6 15/16 in. 14 11/16 in. 15 3/8 in.)Mass (approx.)9.8 kg (21.6 lbs)TypeSpeaker SystemsSubwo
8、ofer 16 cm (6 5/16 in.) cone 1Woofer16 cm (6 5/16 in.) cone 1Mid range7 cm (2 13/16 in.) cone 1Tweeter2 cm (13/16 in.) piezo 1Power handling capacitySubwoofer340 (170 + 170) WMain speaker160 (80 + 80) WImpedanceSubwoofer6 Main speaker4 Frequency rangeSubwoofer25 Hz - 1 000 HzMain speaker50 Hz - 20 0
9、00 HzSound pressure levelSubwoofer73 dB/WmMain speaker82 dB/WmDimensions (W/H/D) (approx.)295 mm 452 mm 387 mm (11 5/8 in . 17 13/16 in . 15 1/4 in.)Mass (approx.)8.6 kg (19.0 lbs) eachRadioFans.CN 收音机爱 好者资料库(No.MB366)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contain
10、s special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be
11、per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibili
12、ty for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-i
13、ng replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List i
14、n the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, t
15、ubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been ret
16、urned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe
17、 to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part hav
18、ing a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W re
19、sistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis,
20、and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety
21、 standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector i
22、s provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-scre
23、enprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer
24、. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB366)1.5Importance administering point on the safetyCaution: For continued protection against risk
25、 of fire,replace only with same type 6.3 A/250 V for RFS1,6.3 A/250 V for RFS05 and RFS06, 8 A/250 V forRFS07 and RFS08, 5 A/250 V for RFS09.This symbol specifies type of fast operating fuse.Precaution: Pour eviter risques de feux, remplacezle fusible de surete de RFS1 comme le meme typeque 6,3 A/25
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-HXC6-cs-sm 维修电路原理图 JVC HXC6 cs sm 维修 电路 原理图