JVC-HXZ9V-cs-sm 维修电路原理图.pdf
《JVC-HXZ9V-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-HXZ9V-cs-sm 维修电路原理图.pdf(109页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.220412003/5COMPACT COMPONENT SYSTEM2204120036HX-Z9VTABLE OF CONTENTS1Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32Dis
2、assembly method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . 1-344Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-40VCDNUMBERVOLUMEPRESETSOUNDMODECOMPACTDIGITAL VIDEOSELECTCA-HXZ9VCOMPACTDIGITAL VIDEOUS - SingaporeArea SuffixRadioFans.CN 收音机爱 好者资料
4、库1-2 (No.22041)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier sectionOutput Power (IEC 268-3)SUBWOOFERS75 W per channel, min. RMS, both channels driven into 6 at 63 Hz with no more than 0.9% total harmonic distortion.MAIN SPEAKERS30 W per channel, min. RMS, bot
5、h channels driven into 6 at 1 kHz with no more than 0.9% total harmonic distortion.Audio input sensitivity/Impedance(Measured at 1 kHz, with tape recording signal 300 mV)AUX390 mV/50 kMIX 1/21.5 mV/5 kSpeakers/ImpedanceSUBWOOFERS6 - 16 MAIN SPEAKERS6 - 16 SURROUND SPEAKERS16 - 32 TunerFM tuning rang
6、e87.50 MHz - 108.00 MHzAM tuning rangeAt 9 kHz intervals 531 kHz - 1 710 kHzAt 10 kHz intervals 530 kHz - 1 710 kHzCD playerCD capacity3 CDsDynamic range85 dBSignal-to-noise ratio90 dBWow and flutterImmeasurableMP3 recording formatMPEG 1/2 Audio Layer 3Max. Bit rate320 kbpsCassette deckFrequency res
7、ponseNormal (type I)50 Hz - 14 000 HzWow and flutter0.15% (WRMS)GeneralPower requirementAC 110 V / AC 127 V / AC 220 V /AC 230 V - AC 240 V (adjustable with the voltage selector), 50 Hz / 60 HzPower consumption205 W (in operation) 23 W (on standby with Ecology Mode off)Less than 3.5 W (on standby wi
8、th Ecology Mode on)Dimensions (approx.)205 mm 370 mm 370 mm (W/H/D)Mass (approx.)10.0 kgRadioFans.CN 收音机爱 好者资料库(No.22041)1-3SECTION 1Precautions1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued
9、 protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product
10、 shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical
11、parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have
12、these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety cha
13、rac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving par
14、ts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the prod
15、uct, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during thi
16、s check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exc
17、eed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good ea
18、rth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat
19、each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standar
20、ds are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left ove
21、r on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such
22、as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each
23、 exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.22041)1.5Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laserdiode in the travers
24、e unit (optical pickup). Take care to prevent this when performing repairs.1.5.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repai
25、rs are being performed. (1) Ground the workbenchGround the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing thetraverse unit (optical pickup) on it.(2) Ground yourselfUse an anti-static wrist strap to release any static electricity built up