1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5082006/6COMPACT COMPONENT SYSTEMMB50820066MX-C55J,MX-C55CLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-105TROUBLESHOOTING . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11ECODISC SKIPSP-MXC55SP-MXC55CA-MXC55RadioFans.CN 收音机爱 好者资料库1-2 (No.MB508)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier sectionCA-MXC55Output PowerSUBWOOFERS170 W p
5、er channel, min. RMS, driven into 3 at 63 Hz with no more than 10% total harmonic distor-tionMAIN SPEAKERS 80 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 10% total harmonic distor-tionAudio input sensitivity/Impedance(at 1 kHz, measured at MAIN SPEAKERS)AUX400 mV/47 kUSBUSB Ver
6、sion 1.1Speakers/ImpedanceSubwoofers3 - 6 Main speakers6 - 16 TunerFM tuning range87.50 MHz - 108.00 MHzAM tuning range530 kHz - 1 710 kHzCD playerCD Capacity3 CDsDynamic range85 dBSignal-to-noise ratio85 dBGeneralPower requirementAC 120 V , 60 HzPower consumption80 W /136 VA (at operation)7.3 W (on
7、 standby)1 W (in ECO mode)Dimensions (approx.)270 mm 317 mm 402 mm (W/H/D)(10 11/16 in. 12 1/2 in. 15 7/8 in.)Mass (approx.)5.9 kg (13 lbs)Speaker sectionSP-MXC55Type3-way bass-reflex typeSpeaker unitsSubwoofer16 cm (6 5/16 in.) cone 1Main Woofer10 cm (3 15/16 in.) cone 1Tweeter5 cm (2 in.) cone 1Po
8、wer handling capacitySubwoofer170 WMain speaker80 WImpedanceSubwoofer3 Main speaker6 Frequency rangeSubwoofer30 Hz - 1 000 HzMain speaker100 Hz - 20 000 HzSound pressure levelSubwoofer74 dB/WmMain speaker81 dB/WmDimensions (approx.)220 mm 435 mm 316 mm (W/H/D)(8 11/16 in. 17 13/16 in. 12 1/2 in.)Mas
9、s (approx.)5.7 kg (12.6 lbs) eachRadioFans.CN 收音机爱 好者资料库(No.MB508)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original de
10、sign unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the produc
11、t shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related charact
12、eristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in th
13、e Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown
14、 inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shoc
15、k and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed m
16、etal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outl
17、et. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC
18、 line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor wi
19、th the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.
20、75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance
21、 with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention
22、to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified
23、by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,o
24、r more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB508)1.5Important for laser products1.CLASS 1 LASER PRODUCT 2.CAUTION : (For U.S.A.) Visible and/or invisible class II laser radiation when open. Do not stare into beam. (Others) Visible and/or invisible class 1M laser radiation when open. Do not vie
25、w directly with optical instruments. 3.CAUTION : Visible and/or invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam.4.CAUTION : This laser product uses visible and/or invisible laser radiation and is equipped with safety switches which prevent emissio