1、 SM0093DR100E SERVICE MANUAL MANUEL DENTRETIEN WARTUNGSHANDBUCH CAUTION: Before servicing this chassis, it is important that the service technician read the “Safety Precautions” and “Product Safety Notices” in this service manual. ATTENTION: Avant deffectuer lentretien du chassis, le technicien doit
2、 lire les Prcautions de scurit et les Notices de scurit du produit prsents dans le prsent manuel. VORSICHT: Vor ffnen des Gehuses hat der Service-Ingenieur die Sicherheitshinweise“ und Hinweise zur Produktsicherheit“ in diesem Wartungshandbuch zu lesen. Data contained within this Service manual is s
3、ubject to alteration for improvement. Les donnes fournies dans le prsent manuel dentretien peuvent faire lobjet de modifications en vue de perfectionner le produit. Die in diesem October 1999 DR100EBSDR100UCDR100WDR100WUNRadioFans.CN 收音机爱 好者资料库SAFETY PRECAUTIONS WARNING: The following precautions mu
4、st be observed. ALL PRODUCTS 1. Before any service is performed on the chassis an isolation transformer should be inserted between the power line and the product. 2. When replacing the chassis in the cabinet, ensure all the protective devices are put back in place. 3. When service is required, obser
5、ve the original lead dressing. Extra precaution should be taken to ensure correct lead dressing in any high voltage circuitry area. 4. Many electrical and mechanical parts in HITACHI products have special safety related characteristics. These characteristics are often not evident from visual inspect
6、ion, nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified by marking with a ? on the schematics and the replacement parts list. The use
7、of a substitute replacement component that does not have the same safety characteristics as the HITACHI recommended replacement one, shown in the parts list, may create electrical shock, fire, X-radiation, or other hazards. 5. Always replace original spacers and maintain lead lengths. Furthermore, w
8、here a short circuit has occurred, replace those components that indicate evidence of overheating. 6. Insulation resistance should not be less than 2M ohms at 500V DC between the main poles and any accessible metal parts. 7. No flashover or breakdown should occur during the dielectric strength test,
9、 applying 3kV AC or 4.25kV DC for two seconds between the main poles and accessible metal parts. 8. Before returning a serviced product to the customer, the service technician must thoroughly test the unit to be certain that it is completely safe to operate without danger of electrical shock. The se
10、rvice technician must make sure that no protective device built into the instrument by the manufacturer has become defective, or inadvertently damaged during servicing. CE MARK 1. HITACHI products may contain the CE mark on the rating plate indicating that the product contains parts that have been s
11、pecifically approved to provide electromagnetic compatibility to designated levels. 2. When replacing any part in this product, please use only the correct part itemised in the parts list to ensure this standard is maintained, and take care to replace lead dressing to its original state, as this can
12、 have a bearing on the electromagnetic radiation/immunity. PICTURE TUBE 1. The line output stage can develop voltages in excess of 25kV; if the E.H.T. cap is required to be removed, discharge the anode to chassis via a high value resistor, prior to its removal from the picture tube. 2. High voltage
13、should always be kept at the rated value of the chassis and no higher. Operating at higher voltages may cause a failure of the picture tube or high voltage supply, and also, under certain circumstances could produce X-radiation levels moderately in excess of design levels. The high voltage must not,
14、 under any circumstances, exceed 29kV on the chassis (except for projection Televisions). 3. The primary source of X-radiation in the product is the picture tube. The picture tube utilised for the above mentioned function in this chassis is specially constructed to limit X-radiation. For continued X
15、-radiation protection, replace tube with the same type as the original HITACHI approved type 4. Keep the picture tube away from the body while handling. Do not install, remove, or handle the picture tube in any manner unless shatterproof goggles are worn. People not so equipped should be kept away w
16、hile picture tubes are handled LASERS If the product contains a laser avoid direct exposure to the beam when the cover is open or when interlocks are defeated or have failed. RadioFans.CN 收音机爱 好者资料库Specifications Track system: 4-track 2-channel Recording system: AC Bias Erasing system: AC Bias Tape
17、speed: 4.75 cm/s Included circuits: Dolby B and C NR, Dolby HX Pro Normal: 40 - 15,000 Hz CrO2: 40 - 16,000 Hz Usable tapes: Metal: 40 - 17,000 Hz Power supply: AC 230 V, 50 Hz (E/EBS), AC 120V 60 Hz (UC), AC 110-127/220-240V 50/60 Hz (W/WUN) Power consumption: 13 W (UC, E, EBS, W, WUN) Maximum exte
18、rnal dimensions: 210 (W) x 96.5 (H) x 316 (D) mm (including feet, controls and terminals) Weight: 2.7 kg * Specifications are subject to change without notice for performance improvements Removal of Top Cover 1. Remove 1 screw ? from each side. 2. Remove 6 screws ? from the rear plate. Removal of Re
19、ar Plate 1. Remove 3 screws ? and 1 screw ? from the rear plate. Removal of Power Cord 1. Detach the power cord connector from connector ?. Removal of Transformer 1. Remove 2 screws ? from the transformer. 2. Pull the transformer upwards to detach its connectors ? and ? from the main P.W.B. board. R
20、emoval of PB P .W.B. Board 1. Remove 1 screw ? from the base plate at the side. 2. Gently pull the PB P.W.B. board upwards to detach its 2 connectors ? from the main P.W.B. board and free the connector ? and ?. Removal of REC P .W.B. Board 1. Release the REC P.W.B. board from its holding claws and t
21、hen gently pull the board free of the connector ?. Removal of Main P .W.B. Board 1. Remove the remaining connectors ? (see Removing Power cord), ? and ? from the main P.W.B. board. 2. Remove 3 screws ? and 1 screw ? from the main P.W.B. board. Removal of Front Panel 1. Remove 1 screw ? from each sid