Integra-DBS6_9-cd-sm 维修电路原理图.pdf
《Integra-DBS6_9-cd-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Integra-DBS6_9-cd-sm 维修电路原理图.pdf(59页珍藏版)》请在收音机爱好者资料库上搜索。
1、DBS-6.9SERVICE MANUALSERVICE MANUALBLU-RAY DISC PLAYERBlack modelMODEL DBS-6.9120V AC, 60HzBCDDRef. No. 4116Oct, 2008RC-731DVSAFETY-RELATED COMPONENT WARNING!COMPONENTS IDENTIFIED BY MARK ON THESCHEMATIC DIAGRAM AND IN THE PARTS LIST ARECRITICAL FOR RISK OF FIRE AND ELECTRIC SHOCK.REPLACE THESE COMP
2、ONENTS WITH ONKYOPARTS WHOSE PART NUMBERS APPEAR AS SHOWNIN THIS MANUAL.MAKE LEAKAGE-CURRENT OR RESISTANCEMEASUREMENTS TO DETERMINE THAT EXPOSEDPARTS ARE ACCEPTABLY INSULATED FROM THESUPPLY CIRCUIT BEFORE RETURNING THEAPPLIANCE TO THE CUSTOMER.RadioFans.CN 收音机爱 好者资料库TABLE OF CONTENTSSpecifications .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1-1Laser Beam Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、1-2-1Important Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3-1Standard Notes for Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5、 . . . . . . .1-4-1Cabinet Disassembly Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5-1How to Initialize the BLU-RAY Disc Player . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6、 . . . . . . . . .1-6-1Firmware Renewal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7-1Block Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7、 . . . . . . . . . . . . . . . . . . .1-8-1Schematic Diagrams / CBA and Test Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9-1Exploded Views. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8、 . . . . . . . . . . . . . . . . . . . . . . .1-10-1Mechanical Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11-1Electrical Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-12-1Manufactured under license from Dolby Laboratories. Dolby and the double-D symbol are trademarks of Dolby Laboratories.RadioFans.CN 收音机爱 好者资料库1-1-1E5H55SPSPECIFICATIONS1-2-1B1.5NLSPLASER BEAM SAFETY PRECAUTIONSThis BD play
10、er uses a pickup that emits a laser beam.The laser beam is emitted from the location shown in the figure. When checking the laser diode, be sure to keep your eyes at least 30 cm away from the pickup lens when the diode is turned on. Do not look directly at the laser beam.CAUTION: Use of controls and
11、 adjustments, or doing procedures other than those specified herein, may result in hazardous radiation exposure.Location: Inside Top of BD mechanism.Do not look directly at the laser beam coming from the pickup or allow it to strike against your skin.Drive Mechanism AssemblyLaser Beam RadiationLaser
12、 PickupTurntable1-3-1B1N_ISPIMPORTANT SAFETY PRECAUTIONSProduct Safety NoticeSome electrical and mechanical parts have special safety-related characteristics which are often not evident from visual inspection, nor can the protection they give necessarily be obtained by replacing them with components
13、 rated for higher voltage, wattage, etc. Parts that have special safety characteristics are identified by a # on schematics and in parts lists. Use of a substitute replacement that does not have the same safety characteristics as the recommended replacement part might create shock, fire, and/or othe
14、r hazards. The Products Safety is under review continuously and new instructions are issued whenever appropriate. Prior to shipment from the factory, our products are carefully inspected to confirm with the recognized product safety and electrical codes of the countries in which they are to be sold.
15、 However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced.Precautions during ServicingA. Parts identified by the # symbol are critical for safety. Replace only with part number specified.B. In addition to safety, other
16、 parts and assemblies are specified for conformance with regulations applying to spurious radiation. These must also be replaced only with specified replacements. Examples: RF converters, RF cables, noise blocking capacitors, and noise blocking filters, etc.C. Use specified internal wiring. Note esp
17、ecially:1) Wires covered with PVC tubing2) Double insulated wires3) High voltage leadsD. Use specified insulating materials for hazardous live parts. Note especially:1) Insulation tape2) PVC tubing 3) Spacers4) Insulators for transistorsE. When replacing AC primary side components (transformers, pow
18、er cord, etc.), wrap ends of wires securely about the terminals before soldering.F.Observe that the wires do not contact heat producing parts (heat sinks, oxide metal film resistors, fusible resistors, etc.).G. Check that replaced wires do not contact sharp edges or pointed parts.H. When a power cor
19、d has been replaced, check that 5 - 6 kg of force in any direction will not loosen it.I.Also check areas surrounding repaired locations.J.Be careful that foreign objects (screws, solder droplets, etc.) do not remain inside the set.K. When connecting or disconnecting the internal connectors, first, d
20、isconnect the AC plug from the AC outlet.1-3-2B1N_ISPSafety Check after ServicingExamine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts, and wires have been returned to their original positions. Afterwards, do the following tests and confirm the sp
21、ecified values to verify compliance with safety standards.1. Clearance DistanceWhen replacing primary circuit components, confirm specified clearance distance (d) and (d) between soldered terminals, and between terminals and surrounding metallic parts. (See Fig. 1)Table 1: Ratings for selected areaN
22、ote:This table is unofficial and for reference only. Be sure to confirm the precise values.2. Leakage Current TestConfirm the specified (or lower) leakage current between B (earth ground, power cord plug prongs) and externally exposed accessible parts (RF terminals, antenna terminals, video and audi
23、o input and output terminals, microphone jacks, earphone jacks, etc.) is lower than or equal to the specified value in the table below.Measuring Method (Power ON):Insert load Z between B (earth ground, power cord plug prongs) and exposed accessible parts. Use an AC voltmeter to measure across the te
24、rminals of load Z. See Fig. 2 and the following table.Table 2: Leakage current ratings for selected areasNote:This table is unofficial and for reference only. Be sure to confirm the precise values.AC Line VoltageClearance Distance (d), (d)120 V 3.2 mm (0.126 inches)AC Line VoltageLoad ZLeakage Curre
25、nt (i)Earth Ground (B) to:120 V0.15 F CAP. & 1.5 k RES. Connected in paralleli 0.5 mA PeakExposed accessible partsChassis or Secondary ConductorPrimary Circuit Fig. 1ddAC Voltmeter (High Impedance)Exposed Accessible PartBEarth Ground Power Cord Plug ProngsZFig. 21-4-1BDN_SNSTANDARD NOTES FOR SERVICI