Yamaha-DRX2-dvd-sm 维修电路原理图.pdf
《Yamaha-DRX2-dvd-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-DRX2-dvd-sm 维修电路原理图.pdf(190页珍藏版)》请在收音机爱好者资料库上搜索。
1、DRX-2DRX-21SERVICE MANUALDVD RECORDERDRX-2100878I CONTENTSTO SERVICE PERSONNEL . 24PREVENTION OF ELECTRO STATIC DISCHARGE . 4LOCALE MANAGEMENT INFORMATION . 4FRONT PANELS. 5REMOTE CONTROL PANEL . 5REAR PANELS . 6SPECIFICATIONS. 68DISASSEMBLY PROCEDURES . 911DIAGNOSTIC SOFTWARE . 1294ALIGNMENTS . 959
2、7CIRCUIT DESCRIPTIONS . 98114ABBREVIATION LIST . 115118IC DATA . 119126BLOCK DIAGRAM. 127WIRING DIAGRAM . 128WAVEFORMS . 129130PRINTED CIRCUIT BOARD . 131149SCHEMATIC DIAGRAM . 150177PARTS LIST. 178189IMPORTANT NOTICEThis manual has been provided for the use of authorized YAMAHA Retailers and their
3、service personnel.It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are alreadyknown and understood by the users, and have therefore not been restated.WARNING:Failure to follow appropriate service and safety procedures when servicing t
4、his product may result in personalinjury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,we advise all YAMAHA product owners that any service required should be performed by an authorizedYAMAHA Retailer or the appointed service representati
5、ve.IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification orrecognition of any applicable technical capabilities, or establish a principle-agent relationship of any form.The data provided is believed to be accurate and applicable
6、to the unit(s) indicated on the cover. The research, engineering, andservice departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitableand specifications are subject to change without notice or obligation to retrofit. Should any discrepancy ap
7、pear to exist, pleasecontact the distributors Service Division.WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may haveaccumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).IMPORTANT:Turn
8、 the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.P.O.Box 1, Hamamatsu, JapanRadioFans.CN 收音机爱 好者资料库DRX-2DRX-22WALLOUTLETEQUIPMENTUNDER TESTAC LEAKAGETESTER OREQUIVALENTINSULATINGTABLEWARNING: CHEMICAL CONTENT NOTICE!The solder used in the pro
9、duction of this product contains LEAD. In addition, other electrical/electronic and /or plastic(where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency(and possibly other entities) to cause cancer and/or birth defects or other reproductive
10、harm.DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-SON WHATSOEVER!Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or exposeeyes to solder/flux vapor!If you come in contact with solder or compon
11、ents located inside the enclosure of this product, wash your hands beforehandling food.I TO SERVICE PERSONNEL1. Critical Components InformationComponents having special characteristics are marked sand must be replaced with parts having specifications equalto those originally installed.2. Leakage Cur
12、rent Measurement (For 120V Models Only)When service has been completed, it is imperative to verifythat all exposed conductive surfaces are properly insulatedfrom supply circuits.GMeter impedance should be equivalent to 1500 ohm shuntedby 0.15F.CAUTION1001 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AG
13、AINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 125mA, 250V FUSE.1300 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 2.5A, 250V FUSE.1303 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 250V FUSE.1304 (ANA
14、LOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 4.0A, 250V FUSE.1306 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 125mA, 250V FUSE.1307 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY
15、WITH SAME TYPE 1.0A, 250V FUSE.1308 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 500mA, 250V FUSE.1309 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 800mA, 250V FUSE.1505 (DIGITAL P.C.B.): FOR CONTINUED PROT
16、ECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE.1506 (DIGITAL P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE.1507 (DIGITAL P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE
17、.CAUTION1001 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 125mA, 250V FUSE.1300 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 2.5A, 250V FUSE.1303 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 1.0A, 250V FUSE.1304 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 4.0A, 250V FUSE.1306 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 12
18、5mA, 250V FUSE.1307 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 1.0A, 250V FUSE.1308 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 500mA, 250V FUSE.1309 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 800mA, 250V FUSE.1505 (DIGITAL P.C.B.): REPLACE WITH SAME TYPE 1.0A, 125V FUSE.1506 (DIGITAL P.C.B.): REPLACE WITH SA
19、ME TYPE 1.0A, 125V FUSE.1507 (DIGITAL P.C.B.): REPLACE WITH SAME TYPE 1.0A, 125V FUSE.ATTENTION1001 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 125mA, 250V.1300 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 2.5A, 250V.1303 (ANALOG P.C.B.): UTILISER UN FUSIBLE
20、DE RECHANGE DE MEME TYPE DE 1.0A, 250V.1304 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 4.0A, 250V.1306 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 125mA, 250V.1307 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 250V.1308 (ANALOG P.C.
21、B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 500mA, 250V.1309 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 800mA, 250V.1505 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 125V.1506 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE
22、1.0A, 125V.1507 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 125V.GLeakage current must not exceed 0.5mA.GBe sure to test for leakage with the AC plug in both polarities.THE DVD RECORDER SHOULD NOT BE ADJUSTED OR REPAIRED BY ANYONE EXCEPT PROPERLY QUALIFIEDSERVICE PERSONNE
23、L.RadioFans.CN 收音机爱 好者资料库DRX-2DRX-23CAUTION: Visible and invisible laserradiationwhen open. Avoid exposure to beam. CLASS 1LASER PRODUCTCAUTION: Visible and invisible laser radiationwhen open. Avoid exposure to beam. Laser Diode PropertiesType:InGaAIP Semiconductor laser (DVD)AlGaAs Semiconductor la
24、ser (CD)Wave length:660 nm (DVD)780 nm (CD)Output Power:20 mW (DVD writing)(out of objective)0.8 mW (DVD reading)0.3mW (CD reading)Beam divergence:82 degrees (DVD)54 degrees (CD)VARO!: AVATTAESSA JA SUOJALUKITUS OHITETTAESSA OLET ALTTIINA NkymTTMLLE LASER-STEILYLLE. L KATSO STEESEEN.VARNING!: OSYNLI
25、G LASERSTRLNING NR DENNA DEL R PPNAD OCH SPRREN R URKOPPLAD.BETRAKTA EJ STRLEN.WARNINGThe use of optical instruments with this product willincrease eye hazard.Repair handling should take place as much as possiblewith a disc loaded inside the player.WARNING LOCATION: Top of the DVDR MechanismWARNING: