1、 1 CDP-EX100SERVICE MANUALAEP ModelUK ModelE ModelModel Name Using Similar MechanismCDP-EX10CD Mechanism TypeCDM28-5BD19Base Unit NameBU-5BD19SPECIFICATIONSCOMPACT DISC PLAYERMICROFILMThis set is the CD player section inMHC-EX50/EX70AV/EX100AV.RadioFans.CN 收音机爱 好者资料库 6 Note :1.Basically designed to
2、operate without adjustment. Therefore, checkeach item in order given.2.Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.3.Use an oscilloscope with more than 10M impedance.4.Clean the objective lens by an applicator with neutral detergentwhen the signal level is low than specified value wit
3、h the followingchecks.5.Adjust the focus bias adjustment when optical block is replaced.Focus Bias AdjustmentSECTION 4ELECTRICAL ADJUSTMENTSProcedure:1.Connect oscilloscope to test point TP (RF). (GND terminal : VC)2.Turn Power switch on.3.Put disc (YEDS-18) in and playback.4.Adjust RV101 so that th
4、e waveform is clear.(Clear RF signal waveform means that the shape “ ” can beclearly distinguished at the center of the waveform.)5.After adjustment, check the RF signal level. RF signalVOLT/DIV : 200 mVTIME/DIV : 500 nSS Curve CheckProcedure:1.Connect oscilloscope to test point TP(FEO).2.Connect be
5、tween test point TP(FOK)and GND by lead wire.3.Turn Power switch on.4.Put disc (YEDS-18) in and turnd Power switch on again andactuate the focus search. (In case of using SERVICE BOX actuatethe focus search when disc table is moving in and out.)5.Check the oscillosope waveform (S-curve) is symmetric
6、al betweenA and B. And confirm peak to peak level within 2.40.7 Vp-p.S-curve waveform6.After check, remove the lead wire connected in step 2.Note : Try to measure several times to make sure than the ratio ofA:B or B:A is more than 10:7. Take sweep time as long as possible and light up thebrightness
7、to obtain best waveform.RF Level CheckProcedure:1.Connect oscilloscope to test point TP (RF) on BD board.2.Turn Power switch on.3.Put disc (YEDS-18) in and playback.4.Confirm that oscilloscope waveform is clear and check RF signallevel is correct or not.Note :Clear RF signal waveform means that the
8、shape “ ” can be clearlydistinguished at the center of the waveform.RF signal waveformBD boardoscilloscopeTP (FEO)TP (FOK)VOLT/DIV : 200mVTIME/DIV : 500nSlevel : 1.30.3 Vp-pBD boardTP (RF)TP (VC)oscilloscopeBD boardTP (RF)VCoscilloscope(DC range)level1.30.3 Vp-psymmetrywithin 2.40.7 Vp-pABRadioFans.