Sony-CDPC335-cd-sup 维修电路原理图.pdf
《Sony-CDPC335-cd-sup 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Sony-CDPC335-cd-sup 维修电路原理图.pdf(43页珍藏版)》请在收音机爱好者资料库上搜索。
1、CDPC235 Subject 2 BD BOARDS USED, ONLY 1 PART # LISTED IN MANUAL SYMPTOMS Only one (1) board listed. This board comes with 8-752-360-75 IC used with KSS-390 optical pickup. No board listed that comes with 8-752-351-94 IC used with the KSS-240A optical pickup.Please advise if we have to change the IC
2、 or if another part # is available. RESOLUTION 4/29/94; As per KCP the part number for the board using the KSS-240A pickup is A4649433A, this number is registered with KCP. A4649610A 157 BD BOARD CDPC235 Subject AFTER PLAYING A FEW SELECTIONS STARTS SKIPPING - REPL OPTICS SYMPTOMS After playing a fe
3、w selections, the unit starts skipping. RESOLUTION Replaced optical device. 884828111 151 KSS390A CDPC235 Subject AFTER WARM UP, DISPLAY BLINKS AND STOP PLAYING SYMPTOMS RadioFans.CN 收音机爱 好者资料库After unit warmed up, display blinks and stop playing during track change and look for another disc. After
4、intensive trouble shooting, we found a defective diode in positive 9.5V supply. If 9.5V supply drops to below 6.8V, unit will reset. We think, diode is not big enough to handle heavy loads. RESOLUTION We recieved Sutos information that samples are on the way. We will wait for the samples and look in
5、to this situation at that time. Update 9/21/94: The Samples have not yet arrived, since this is the only report of this type of problem regarding the CPDC235 we will close this issue, We will however, watch for further reports. 871920082 D201 B21/DIODE 11ES2 CDPC235 Subject BU UNIT HITS DISC TABLE W
6、HEN CHUCKING SYMPTOMS On 2 different units the laser hits the disc table when chucking. It appears disc table, ref# 59, is stopping too far clockwise. The pin on ref# 123 is against the left side of the slot in ref# 59. Is there any adjustment? What makes the table stop in this particular place? RES
7、OLUTION (Feb 5) Replacing R458 with a 3K, 1/6 W (P/N 124784200) and R457 with a 5.6k, 1/6 W (P/N 12784900) repaired a unit sent to Tech. department. R459 is a 2.1k and was already installed on the unit worked on at Tech Dept. Positive feedback from Boston and Atlanta. -UPDATE: From Tokyo: 4/11, Repl
8、ace IC401 with p/n 875284942, verify R457 - 2.4 k ohm, R458 - 750 ohm, R459 - 1.2k ohm resistor p/ns listed in S/M. CDPC235 Subject DEAD UNIT - POWER TRANFORMER OPENED SYMPTOMS RadioFans.CN 收音机爱 好者资料库Checked and found open primary (thermal fuse) in power transformer. Noticed that Q504 and Q502 had o
9、verdissipated. Checked both transistors and found shorted collector/emitters on both. Replaced Q502, Q503 and Q504. Then found that IC501 pins 13 and 19 were at -1vdc and +1vdc. RESOLUTION Replaced power transformer Q502, Q503, Q504 and IC501. Normal operation restored. 142355311 T901 POWER TRANSFOR
10、MER CDPC235 Subject DISC TRAY, ROTATES CONTINUOUSLY (REPLACE D801) SYMPTOMS At power on disc tray would spin and not stop. Other functions were normal (open/close). RESOLUTION By checking D801 connector main board, voltages were correct but, pin 5 (T. Sens) data looked bad. Replaced D801, solved pro
11、blem. The purpose of D801 is to sense the location of the disc tray by detecting the slots in the tray and outputting pulses to the micro IC401 (pin 6). 874992418 D801 J8/IC RPI 1391 CDPC235, CDPC335Subject INTERMITTANT AUDIO - REPLACED BD TO MAIN BD FLEX CABLE SYMPTOMS Right or left channel intermi
12、ttently cutting out. RESOLUTION Replaced flex cable from BD board to main board. 164840911 122 FLEX CABLE CDPC235, CDPC335Subject JAMS DISC TABLE, WONT PLAY DISCS - REPLACE GEAR 61 AND 66 SYMPTOMS Unit will not play discs. BU assembly wont come up, due to interference with disc table. Occasionally,
13、the CLV motor pulley is damaged. RESOLUTION To repair this problem as per Tokyo: Replace IC 401 with P/N 8-752-849-42, also verify values of R457 (2.4 ohm) R458 (750 ohm) and R459 (1.2k ohm). The P/Ns of the resistors are listed in the S/M. A Service Bulletin is in the process of being issued to com
14、pletely list part numbers and serial number ranges. X49433791 61 GEAR, ROTARY A, ASSY CDPC235, CDPC335Subject MECHANICAL ALIGNMENT PROCEDURE AVAILABLE, SEE S/M SUPP. #2 SYMPTOMS The unit had no mechanical movement. I found the above part out of item number 119 slot (down position on both units). RES
15、OLUTION I reinstalled item number 123 into the slot on number 119 and the unit restored operation. Is there any written alignment procedure for this new mechanism? We have asked Tokyo to provide the alignment procedure. -UPDATE: Please refer to service manual supplement #1 for the mechanical alignme
16、nt procedure. 495728901 123 BU-5BD (BASE UNIT) CDPC235 Subject NO AUDIO - REPLACED OPTICAL DEVICE AND CABLES 122 AND 153 SYMPTOMS Unit had no audio traced problem to defective cables, than unit was skipping. Found defective optics. RESOLUTION Replaced cables 122 and 153 and optical device. 884828111
17、 151 KSS390A CDPC235 Subject STATIC IN AUDIO OUT - REPLACED IC501 SYMPTOMS Static in audio, traced signal to IC501 sound was good going into the IC but bad going out. RESOLUTION Replace IC501. 875917588 IC501 D19/LINE AMP/MUTING ATT CDPC235 Subject TABLE KEEPS ROTATING WITH LESS THAN 3 DISCS SYMPTOM
18、S With less than 3 discs in unit the table will continue to rotate unless you put some pressure on the turntable to slow it down. With 3 discs it will detect the discs and play them. With 1-2 discs it will not detect the discs and play unless you put slight pressure on the side of the turntable. RES
19、OLUTION Try replacing the resistors as outlined in FPR P0144, this mod will slightly slow the rotation of the disc table. As per our conversation, this resistor mod solved the problem. CDPC235 Subject WEAK RIGHT CHANNEL - REPLACED LINE AMP IC501 SYMPTOMS Right channel is weak. RESOLUTION Replaced li
20、ne amp IC; normal operation restored. The line amp supplies L and R audio signals to the line out jacks and the headphone amp (IC551) the same symptom, low right audio, will be noticable through both outputs. 875906166 IC501 D19/LINE AMP CDPC235, CDPC435, CDPC535Subject TRAY MOTOR SPINNING BACKWARDS
21、 - REPLACE TABLE MOTOR SYMPTOMS Ran into this problem 5 times in past 3 weeks. Removed tray motor. Old motor is installed with lable on motor facing up. If new motor is installed with label facing up, motor will spin backwards and tray will not function properly. RESOLUTION When replacing this motor
22、, I installed it with label facing down so it spins the correct way. Replaced motor because of tray hitting the BU mech. Tried resistor mod but it did not work. If the mod doesnt work, tray motor will usually fix the problem. A4660322A M801 DISC TABLE MOTOR CDPC235 Subject WONT READ COMPLETE DISC -
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Sony-CDPC335-cd-sup 维修电路原理图 Sony CDPC335 cd sup 维修 电路 原理图