LG-DR165-cd-sm 维修电路原理图.pdf
《LG-DR165-cd-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《LG-DR165-cd-sm 维修电路原理图.pdf(108页珍藏版)》请在收音机爱好者资料库上搜索。
1、DVD RECORDERSERVICE MANUALMODEL : DR165/DR175/DR676XCAUTIONBEFORE SERVICING THE UNIT, READ THE “SAFETYPRECAUTIONS”IN THIS MANUAL.MODEL : DR165/DR175/DR676XSERVICE MANUALRadioFans.CN 收音机爱 好者资料库CONTENTSSECTION 1 . . . . SUMMARYSECTION 2 . . . . CABINET & MAIN CHASSISSECTION 3 . . . . ELECTRICALSECTION
2、 4 . . . . RS-01A LOADER PARTSECTION 5 . . . . REPLACEMENT PARTS LISTRadioFans.CN 收音机爱 好者资料库1-1SECTION 1SUMMARYCONTENTSPRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS. 1-2SERVICING PRECAUTIONS. 1-3 General Servicing Precautions Insulation Checking Prodedure Electrostatically Sensitive Devices
3、SERVICE INFORMATION FOR EEPROM IC SETTING. 1-4FLASH UPGRADE. 1-5LOADER UPGRADE. 1-7SPECIFICATIONS. 1-91-21-2IMPORTANT SAFETY NOTICEThis manual was prepared for use only by properly trained audio-video servicetechnicians.When servicing this product, under no circumstances should the originaldesign be
4、 modified or altered without permission from LG ElectronicsCorporation. All components should be replaced only with types identical tothose in the original circuit and their physical location, wiring and lead dressmust conform to original layout upon completion of repairs.Special components are also
5、 used to prevent x-radiation, shock and fire haz-ard. These components are indicated by the letter “x” included in their compo-nent designators and are required to maintain safe performance. No deviationsare allowed without prior approval by LG Electronics Corporation.Circuit diagrams may occasional
6、ly differ from the actual circuit used. This way,implementation of the latest safety and performance improvement changesinto the set is not delayed until the new service literature is printed.CAUTION: Do not attempt to modify this product in any way. Never performcustomized installations without man
7、ufacturers approval. Unauthorized modi-fications will not only void the warranty, but may lead to property damage oruser injury.Service work should be performed only after you are thoroughly familiar withthese safety checks and servicing guidelines.GRAPHIC SYMBOLSThe exclamation point within an equi
8、lateral triangle is intended toalert the service personnel to important safety information in theservice literature.The lightning flash with arrowhead symbol within an equilateraltriangle is intended to alert the service personnel to the presenceof noninsulated “dangerous voltage” that may be of suf
9、ficientmagnitude to constitute a risk of electric shock.The pictorial representation of a fuse and its rating within an equi-lateral triangle is intended to convey to the service personnel thefollowing fuse replacement caution notice: CAUTION: FOR CONTINUED PROTECTION AGAINST RISKOF FIRE, REPLACE AL
10、L FUSES WITH THE SAME TYPE ANDRATING AS MARKED NEAR EACH FUSE.SERVICE INFORMATIONWhile servicing, use an isolation transformer for protection from AC line shock.After the original service problem has been corrected, make a check of the fol-lowing:FIRE AND SHOCK HAZARD1. Be sure that all components a
11、re positioned to avoid a possibility of adjacentcomponent shorts. This is especially important on items trans-ported to andfrom the repair shop.2. Verify that all protective devices such as insulators, barriers, covers, shields,strain reliefs, power supply cords, and other hardware have been reinsta
12、lledper the original design. Be sure that the safety purpose of the polarized lineplug has not been defeated.3. Soldering must be inspected to discover possible cold solder joints, soldersplashes, or sharp solder points. Be certain to remove all loose foreign par-ticles.4. Check for physical evidenc
13、e of damage or deterioration to parts and compo-nents, for frayed leads or damaged insulation (including the AC cord), andreplace if necessary.5. No lead or component should touch a high current device or a resistor ratedat 1 watt or more. Lead tension around protruding metal surfaces must beavoided
14、.6. After reassembly of the set, always perform an AC leakage test on allexposed metallic parts of the cabinet (the channel selector knobs, antennaterminals, handle and screws) to be sure that set is safe to operate withoutdanger of electrical shock. DO NOT USE A LINE ISOLATION TRANS-FORMER DURING T
15、HIS TEST. Use an AC voltmeter having 5000 ohms pervolt or more sensitivity in the following manner: Connect a 1500 ohm, 10watt resistor, paralleled by a .15 mfd 150V AC type capacitor between aknown good earth ground water pipe, conduit, etc.) and the exposed metal-lic parts, one at a time. Measure
16、the AC voltage across the combination of1500 ohm resistor and .15 mfd capacitor. Reverse the AC plug by using anon-polarized adaptor and repeat AC voltage measurements for eachexposed metallic part. Voltage measured must not exceed 0.75 volts RMS.This corresponds to 0.5 milliamp AC. Any value exceed
17、ing this limit consti-tutes a potential shock hazard and must be corrected immediately.TIPS ON PROPER INSTALLATION1. Never install any receiver in a closed-in recess, cubbyhole, or closely fittingshelf space over, or close to, a heat duct, or in the path of heated air flow.2. Avoid conditions of hig
18、h humidity such as: outdoor patio installations wheredew is a factor, near steam radiators where steam leakage is a factor, etc.3. Avoid placement where draperies may obstruct venting. The customershould also avoid the use of decorative scarves or other coverings thatmight obstruct ventilation.4. Wa
19、ll- and shelf-mounted installations using a commercial mounting kit mustfollow the factory-approved mounting instructions. A product mounted to ashelf or platform must retain its original feet (or the equivalent thickness inspacers) to provide adequate air flow across the bottom. Bolts or screwsused
20、 for fasteners must not touch any parts or wiring. Perform leakage testson customized installations.5. Caution customers against mounting a product on a sloping shelf or in a tilt-ed position, unless the receiver is properly secured.6. A product on a roll-about cart should be stable in its mounting
21、to the cart.Caution the customer on the hazards of trying to roll a cart with small cast-ers across thresholds or deep pile carpets.7. Caution customers against using extension cords. Explain that a forest ofextensions, sprouting from a single outlet, can lead to disastrous conse-quences to home and
22、 family.A.C. Voltmeter1500 OHM10 WATTPlace this probeon each exposedmetal part.Good Earth Groundsuch as the WaterPipe, Conduit, etc.0.15uFPRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS1-3SERVICING PRECAUTIONSCAUTION : Before servicing the DVD Recorder covered bythis service data and its supp
23、lements and addends, read andfollow the SAFETY PRECAUTIONS. NOTE : if unforeseencircumstances create conflict between the following servic-ing precautions and any of the safety precautions in this pub-lications, always follow the safety precautions.Remembers Safety First:General Servicing Precaution
24、s1. Always unplug the DVD Recorder AC power cord from theAC power source before:(1)Removing or reinstalling any component, circuit board, module, or any other assembly.(2)Disconnection or reconnecting any internal electricalplug or other electrical connection.(3)Connecting a test substitute in paral
25、lel with an elec-trolytic capacitor.Caution : A wrong part substitution or incorrect polarity installation of electrolytic capacitors may resultin an explosion hazard.2. Do not spray chemicals on or near this DVD Recorder orany of its assemblies.3. Unless specified otherwise in this service data, cl