JVC-XLR910SL-cd-sm 维修电路原理图.pdf
《JVC-XLR910SL-cd-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-XLR910SL-cd-sm 维修电路原理图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOMPACT DISC RECORDERNo.A0009Apr. 2001COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.XL-R910SLXL-R910SLArea SuffixJ - U.S.A.C - CanadaB - U.K.E - Continental EuropeEN - Northern EuropeThis service manual is printed on 100% recycled paper.ContentsSafety precautions - 1-2Disassembly method
2、- 1-3Troubleshooting - 1-6Description of major ICs - 1-11RadioFans.CN 收音机爱 好者资料库XL-R910SL1-21. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless autho
3、rized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be
4、made. Any design alterations or additions will void the warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteri
5、stics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Man
6、ual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Serv
7、ice Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. Whe
8、n service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassembling.5. Leakage current check (Electrical shock hazard testing)After reassembling the product, always perform an isolation check on the expo
9、sed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the A
10、C outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet , particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.)Alternate check methodPlug
11、the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across t
12、he resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured An
13、y must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with
14、the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivit
15、y)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.RadioFans.CN 收音机爱 好者资料库XL-R910SL1-3Disassembly methodRemoving the metal cover (See Fig.1)Removing the front panel
16、 assembly (See Fig.25)1.Remove the three screws A attaching the metal cover on the back of the body.2.Remove the four screws B attaching the metal cover on both sides of the body.3.Remove the metal cover from the body by lifting the rear part of the cover. ATTENTION : Do not break the front panel ta
17、b fitted to the metal cover. * Prior to performing the following procedure, remove the metal cover.1.Remove the three screws C attaching the front panel assembly on the bottom of the body and both sides of the body.2.Disconnect the card wire from connector CN601 on the servo control board.3.Disconne
18、ct the 4pin wire from connector CN502 on the servo control board.4.Disconnect the 3pin wire and 8pin wire from connector ACW1 and RCW2 on the main board. Please remove a tie band if necessary. Please fix the wire again with a tie band when assembling. 5.Release the two joints a on the lower part of
19、the sides using a screwdriver, and remove the front panel assembly toward the front.Fig. 2Fig. 3Fig. 4CCMetal coverB x 2AAAFig. 1B x 2CFront panel assemblyjoint aJoint aFront panel assemblyFront panel assemblyFig. 5ACW1Main boardTie bandTie bandGNCW1CN502CN701CN601DFFRCW1RCW2MechanismassemblyXL-R910
20、SL1-4Removing the power button arm (See Fig.6) * Prior to performing the following procedure, remove the metal cover and front panel assembly. The power button arm is lifted up while holding the power switch(orange color part) and removes.Removing the mechanism assembly (See Fig.6) * Prior to perfor
21、ming the following procedure, remove the metal cover and front panel assembly.1.Disconnect the card wire from connector CN501 on the servo control board.2.Disconnect the 6pin wire from connector CN701 on the servo control board.3.Remove the four screws D attaching the mechanism assembly. *Please fix
22、 two earth wires together when you install the mechanism assembly. Removing the main board (See Fig.5,7) * Prior to performing the following procedure, remove the metal cover.1.Remove the four screws E attaching the each terminal on the rear panel.2.Disconnect the 9pin,8pin and 3pin wire from connec
23、tor RCW1,RCW2 and ACW1 on the main board.3.Disconnect the card wire from connector NCW1 on the main board.4.Disconnect the 6pin wire from connector CN701 on the servo control board.5.Remove the screw D attaching the earth wire.6.Remove the two screws F and one screw G attaching the main board. Pleas
24、e remove a tie band if necessary. Please fix the wire again with a tie band when assembling. Fig. 6Main boardDDDDMechanismassemblyPowerbuttonarmOrangecolor partEarth wireCN501CN701Earth wireFig. 7EEEECord bushingFig. 5ACW1Main boardTie bandTie bandGNCW1CN502CN701CN601DFFRCW1RCW2MechanismassemblyXL-R
25、910SL1-5Removing the power transformer (See Fig.68) * Prior to performing the following procedure, remove the metal cover.1.Power button arm is removed from power switch2.Disconnect 9pin wire from connector RCW1 on the main board.3.The code bushing is pulled out for above. 4.Remove the four screws H
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-XLR910SL-cd-sm 维修电路原理图 JVC XLR910SL cd sm 维修 电路 原理图