1、1.913.101-.108/.321-.324/.605-.610 Date printed: 12.06.2002 10.27.1481 (0602) VU/PPM Meters 1 VU/PPM LED Level Meter Modules Contents 1 General.2 2 Functional Description.3 3 Technical Specifications.3 4 Block Diagram .4 5 Alignment.4 Diagrams PCB No. Diagram Component Layout Parts List VU/PPM 30 LE
2、D with GRM 1.913.293.00 1.913.293.00 VU/PPM 30 LED 1.913.294.00 1.913.293.00 1.913.293.00 1.913.294.00 LED PPM Meter (10 LED) 1.913.291.00 1.913.291.00 1.913.291.00 1.913.291.00 Scope of Validity These instructions apply to the following assemblies: Display 1 Channel, dark front panel 2 Channels, da
3、rk front panel 2 Channels, bright front panel 4 Channels, dark front panel PCB No. PPM 1.913.101 1.913.105 1.913.605 1.913.321 1.913.294 VU 1.913.102 1.913.106 1.913.606 1.913.322 1.913.294 PPM w. GRM 1.913.103 1.913.107 - 1.913.323 1.913.293 VU w. GRM 1.913.104 1.913.108 - 1.913.324 1.913.293 PPM w
4、. additional small level meter - - 1.913.610 - 1.913.294, 1.913.291 RadioFans.CN 收音机爱 好者资料库1.913.101-.108/.321-.324/.605-.610 2 VU/PPM Meters 10.27.1481 (0602) Date printed: 12.06.2002 1 General The Level Meter units with 30 LEDs have been developed for installation in the display panel of Studer Mi
5、xing Consoles. Instruments with VU (vol-ume unit) and PPM (peak program meter) characteristics, with or without gain reduction meter (GRM) are available. Instead of bar-graph indication, also dot indication is optionally available. The instruments listed below are equipped with the PCBs 1.913.294 (V
6、U or PPM) or 1.913.293 (VU or PPM with gain reduction meter) according to the table above. Please consult the circuit diagram relating to the corre-sponding assembly number. VU Meters: PPM Meters: 2010dBGRM20dB10753210123+VU10080406020%2010dBGRM20dB10753210123+VU10080406020%1008080406020%2010dBGRM20
7、dB10753210123+VU10080406020%2010dBGRM20dB10753210123+VU10080406020%2010dBGRM20dB10753210123+VU10080406020%2010dBGRM20dB10753210123+VU10080406020%1002010dBGRMdB12+PPM2010dBGRM2010dBGRM2010dBGRM2010dBGRM2010dBGRM606121824dB12+PPM606121824dB12+PPM606121824dB12+PPM606121824dB12+PPM606121824dB12+PPM60612
8、182420dB10753210123+VU10080406020%1008080406020%100dB12+PPM606121824dB12+PPM606121824 7+ 3+ 2+ 10 1 3 51020dB+ 3+ 2+ 10 1 3 51020dB1.913.102 *1.913.1041.913.106 *1.913.1081.913.322 *1.913.3241.913.101 *1.913.1031.913.105 *1.913.1071.913.321 *1.913.323* Versions without gain reduction meter (GRM)1.91
9、3.606 *1.913.605 *1.913.610 *40401201701704040120404040190190RadioFans.CN 收音机爱 好者资料库1.913.101-.108/.321-.324/.605-.610 Date printed: 12.06.2002 10.27.1481 (0602) VU/PPM Meters 3 2 Functional Description PPM: The peak program meter is a quasi-peak value instrument with long decay time. When a signal
10、voltage corresponding to a level of 0 dB is applied for 10 ms, the resulting indication is 1 dB. Decay time (0 to 20 dB) is 1.7 s. VU Meter: The VU meter indicates signals according to the standard defined by ANSI 1954. When a signal with a duration of 300 ms is applied, the indication is 99% of the
11、 reference value. Rise and decay times on a VU meter are iden-tical. The factory-set lead is +6 dB. Gain Reduction Meter: When the limiter/compressor is switched on, the GRM indicates the magni-tude of the gain reduction. Small PPM: The assembly 1.913.610 contains an additional small PPM meter with
12、10 LEDs, normally used for AUX level indication. Bar/Dot Display Selection: On each of the PCBs, selection of bar or dot display mode is provided. All level meters are factory-set to bar display mode; dot display mode is un-usual and recommended only if extra-low current consumption is required. PCB
13、 No. Bar Display Mode (Default Factory Setting) Dot Display Mode 1.913.293.00 (VU/PPM 30 LED w. GRM) insert: R3, R8, R10, R15 remove: R4, R9, R11, R14 insert: R4, R9, R11, R14 remove: R3, R8, R10, R15 1.913.294.00 (VU/PPM 30 LED) insert: R3, R8, R10 remove: R4, R9, R11 insert: R4, R9, R11 remove: R3
14、, R8, R10 1.913.291.00 (PPM 10 LED) insert jumper JS201 remove jumper JS201 3 Technical Specifications General: 0 dBu 0.775 Vrms Sensitivity for reference indication 1 dBu . +16 dBu Input impedance 10 k Supply 15 VDC +24 VDC Quiescent: 45 mA 35 mA Current consumption without GRM (p. ch., bar display
15、 mode) Full load: 80 mA 80 mA Quiescent: 55 mA 45 mA Current consumption with GRM (p. ch., bar display mode) Full load: 105 mA 105 mA VU Meter (1.913.293): Indication range 20 VU . +3 VU Accuracy (conditions: 10.+3 VU, 0.+50 C, 31.5 Hz.16 kHz) 1 segment Response time to 1 VU 207 ms 30 ms PPM (1.913.
16、293): Indication range 30 dBu . +15 dBu Accuracy (conditions: 30.+15 VU, 0.+50 C, 31.5 Hz.16 kHz) 1 segment Dynamic behavior 0 dB, 10 ms burst Indication: 1 dB 0.5 dB Jumper normal 0 dB, 3 ms burst Indication: 4 dB 1 dB Jumper fast 0 dB, 100 s burst Indication: 1 dB Decay time: 0.20 dB 1.7 s 0.3 s G
17、RM (1.913.294): Input voltage range min. control: 0 V . +2 VDC max. control: 0 V . +11 VDC Dimensions: 1- and 2-channel units, dark front panel (w h d) 40 170 97 mm 2-channel units, bright front panel (w h d) 40 190 97 mm 4-channel units, dark front panel (w h d) 120 170 97 mm 1.913.101-.108/.321-.3
18、24/.605-.610 4 VU/PPM Meters 10.27.1481 (0602) Date printed: 12.06.2002 4 VU/PPM Meter Block Diagram VU/PPM meter block diagram: VU/PPM/PPM FAST and LIN/LOG settings are established with jumpers J2 and J3, respectively. 5 Alignment Required Instruments: AC voltmeter, Ri 20 k DC voltmeter, Ri 100 k A
19、F generator, 31.5 Hz . 16 kHz, 0.16 dBu; attenuator with 10 dB incre-ments. DC/DC Converter Check: Connect DC voltmeter to TP5 (hot) and TP4 (ground). Feed generator out-put signal with line level (1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9); all green LEDs are on. DC voltmeter read
20、ing should be: 3.1 0.1 VDC (supply: +24 VDC), 4.1 0.1 VDC (supply: +30 VDC). Input Range: Feed generator output signal with line level (1 kHz, 1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Connect AC voltmeter to test points TP1 (hot) and TP4 (ground). Reading must be adjustable with
21、 RA3 to 290 10 mVAC for the complete input level range. Line Level: Feed generator output signal with your line level (1 kHz, range: 1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Adjust RA3 until all green LEDs are on. The red LEDs must be dark. (TP3: 2.5 0.1 VDC). Rectifier and Indi
22、cation: Set J2 to VU, J3 to LIN. Feed generator output signal with your line level (1 kHz, usually 0 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Connect AC voltmeter to test points TP1 (hot) and TP4 (ground). Adjust with RA3 to 290 10 mVAC. All green LEDs must be on. Connect DC voltmeter
23、 to test points TP2 (hot) and TP4 (ground); the meter should read 380 15 mVDC. Connect DC voltmeter to test points TP3 (hot) and TP4 (ground); the meter should read +2.575 0.100 VDC. All green LEDs must be on. Check: Set generator output for a DC voltmeter reading of 3.8 0.1 VDC. All LEDs must be on
24、. Set generator output for a DC voltmeter reading of 170 20 mVDC. Only the lowest LED must be on. TP1TP3TP2LIN (VU)LOG (PPM)LOGT213PPMPPM FASTVU1.+16 dBu24.30 VDC3.4.5 VDC (LED)10 LED red20 LED grnDCDC1.913.101-.108/.321-.324/.605-.610 Date printed: 12.06.2002 10.27.1481 (0602) VU/PPM Meters 5 Log C
25、onverter (PPM only): Set J2 to PPM, J3 to LOG. Feed generator output signal (1 kHz, +6 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Connect DC voltmeter to test points TP2 (hot) and TP4 (ground). Adjust with RA3 to 1.18 0.05 VDC. RA1 and RA2: Basic setting according to the arrows in the d