1、?Latin America After Sales Indianapolis IN 46290 U.S.A. ? ? ? ?!?#?$?% ? ?#?$? ? ?#? ? ? ?!?#?$?%? ?&?(? ?)*? ?+? ? ?!#$%!?&??(?)?#RadioFans.CN 收音机爱 好者资料库SAFETY PRECAUTIONS1. Before returning the instrument to the customer, alwaysmake a safety check of the entire instrument, including, but notlimi
2、ted to, the following items:a. Be sure that no built-in protective devices are defective and/or have been defeated during servicing. (1) Protectiveshields are provided on this instrument to protect both thetechnician and the customer. Correctly replace all missingprotective shields, including any re
3、moved for servicingconvenience. (2) When reassembling the instrument, besure to put back in place all protective devices, including, butnot limited to, nonmetallic control knobs, insulating fishpapers,adjustment and compartment covers/shields, and isolationresistor/capacitor networks. Do not operate
4、 this instrumentor permit it to be operated without all protective devicescorrectly installed and functioning. Servicers who defeatsafety features or fail to perform safety checks may beliable for any resulting damage, and may exposethemselves and others to possible injury.b. Be sure that there are
5、no cabinet openings through which anadult or child might be able to insert their fingers and contacta hazardous voltage. Such openings include, but are notlimited to, (1) excessively wide cabinet ventilation slots, and(2) improperly fitted and/or incorrectly secured cabinet covers.c. Leakage Cold Ch
6、eck - With the instrument AC plug removedfrom any AC source, connect an electrical jumper across thetwo AC plug prongs. Place the instrument AC switch in theon position. Connect one lead of an ohmmeter to the AC plugprongs tied together and touch the other ohmmeter lead inturn to each push button/cu
7、stomer control, exposed metalscrews, metallized overlays and to each cable connector. Ifthe measured resistance is less than 1.0 megohm or greaterthan 5.2 megohm an abnormality exists that must be correctedbefore the instrument is returned to the customer. Repeatthis test with the AC switch in the o
8、ff position.d. Leakage Current Hot CheckOn completely assembled instrument, plug the AC line corddirectly into a 120V AC outlet. (Do not use an isolationtransformer during this test.) Use a leakage current tester ora metering system that complies with American NationalStandards Institute (ANSI) C101
9、.1 Leakage Current forAppliances and Underwriters Laboratories (UL) 1492 (Section67). Measure for current from a known earth ground (metalwaterpipe, conduit, etc.) to all exposed metal or conductiveparts of the instrument (antenna connections, handle bracket,metal cabinet, screwheads, metallic overl
10、ays, push-buttons,control shafts, etc.), especially any exposed metal parts thatoffer an electrical return path to the chassis. Any currentmeasured must not exceed 0.5 milliamp. Reverse theinstrument power cord plug in the outlet and repeat the test.ANY MEASUREMENTS NOT WITHIN THE LIMITSSPECIFIED HE
11、REIN INDICATE A POTENTIAL SHOCKHAZARD THAT MUST BE ELIMINATED BEFORERETURNING THE INSTRUMENT TO THE CUSTOMER ORBEFORE CONNECTING TO ANTENNA ORACCESSORIES.e. Interconnected Equipment AC Leakage TestAvoid shock hazards. The instrument, accessory, or cable(s)to which this instrument is connected should
12、 have theapplicable sections of the leakage resistance cold check andthe leakage current hot check performed. Do not connectthis instrument to an antenna, cable or accessory thatexhibits excessive leakage currents.2. Read and comply with all caution and safety-related notes on orinside the instrumen
13、t cabinet, and on the chassis.3. Design Alteration Warning - Do not alter or add to the mechanicalor electrical design of this instrument. Design alterations andadditions, including, but not limited to, circuit modifications andthe addition of items such as auxiliary audio output connections,cables
14、and accessories, etc., might alter the safety characteristicsof this instrument and create a hazard to the user. Any designalterations or additions will void the manufacturers warranty andwill make you, the servicer responsible for personal injury orproperty damage resulting therefrom.4. Observe ori
15、ginal lead dress. Take extra care to assure correctlead dress in the following areas: (a) near sharp edges, (b) nearthermally hot parts - be sure that leads and components do nottouch thermally hot parts, and (c) the AC supply. Always inspectin all areas for pinched, out-of-place, or frayed wiring.