1、 Panasonic Corporation 2017. All rights reserved.Unauthorized copying and distribution is a violationof law.PSG1704003CEA6Stereo Integrated AmplifierModel No.SU-G700ESU-G700PPProduct Color: (S).Silver Type TABLE OF CONTENTSPAGEPAGE1 Safety Precautions- 31.1. General Guidelines- 31.2. Before Repair a
2、nd Adjustment- 41.3. Protection Circuitry- 51.4. Safety Parts Information- 52 Warning- 62.1. Prevention of Electrostatic Discharge (ESD)to Electrostatically Sensitive (ES) Devices- 62.2. General description about Lead Free Solder(PbF)- 62.3. Grounding for electrostatic breakdownprevention - 73 Servi
3、ce Navigation- 83.1. Service Information - 84 Specifications - 95 Location of Controls and Components -105.1. Remote Control Key Button Operation-105.2. Main Unit Key Button Operation-116 Service Mode -126.1. Doctor Mode-126.2. Error Code Table- 157 Troubleshooting Guide - 167.1. Check the problem i
4、s reproduced- 167.2. No power- 177.3. Automatically shutdown during operation- 207.4. No Display - 217.5. Power Indicator - Not Light - 227.6. Meter Illumination - No Light - 237.7. No Remote Control Operation- 247.8. Can not control Volume +/- - 257.9. Can not control Input Selection- 267.10. No SU
5、B Function (Firmware UPDATEterminal)- 277.11. No Sound input from PC (USB-B), COAX INor OPT IN - 287.12. No Sound from Speaker Unit - 297.13. No Sound from Headphone - 307.14. No Sound from LINE OUT Terminal- 317.15. No Meter Operation - 327.16. No System Control (Control Terminal)- 33RadioFans.CN 收
6、音机爱 好者资料库27.17. No Audio Output from PRE OUT terminal -347.18. No LAPC Function-347.19. Pin function of each connectors-357.20. Function and Possible failure PCB or Module -368 Disassembly and Assembly Instructions-378.1. Type of Screws -378.2. Disassembly Flow Chart-388.3. Main Components and P.C.B
7、. Locations-398.4. Disassembly of Top Cabinet Assy-408.5. Disassembly of SMPS P.C.B. -408.6. Disassembly of AMP P.C.B. -418.7. Disassembly of Speaker L P.C.B. and SpeakerR P.C.B. -428.8. Disassembly of Control P.C.B. -428.9. Disassembly of Digital P.C.B. -438.10. Disassembly of REC Out P.C.B. -438.1
8、1. Disassembly of Main P.C.B. -448.12. Disassembly of Front Panel Unit-448.13. Disassembly of Selector P.C.B.-458.14. Disassembly of Volume P.C.B.-458.15. Disassembly of Main SW P.C.B. -468.16. Disassembly of OLED P.C.B. -468.17. Disassembly of Shade Sheet B -468.18. Disassembly of Headphone P.C.B.-
9、468.19. Disassembly of Meter Illumi LED L P.C.B. andMeter Illumi LED R P.C.B.-478.20. Disassembly of Meter P.C.B.-478.21. Disassembly of Meter Unit-479 Service Position-489.1. Checking and Repairing of SMPS P.C.B.,AMP P.C.B., Main P.C.B., Control P.C.B.,Digital P.C.B. and REC Out P.C.B. -4810 Measur
10、ement and Adjustment-4910.1. Adjustment of the Peak Power Meter-4911 Block Diagram -5112 Wiring Connection Diagram-5213 Exploded View and Replacement Parts List-5313.1. Cabinet Parts Location 1-5313.2. Cabinet Parts Location 2-5413.3. Cabinet Parts Location 3-5513.4. Packaging-5613.5. Mechanical Rep
11、lacement Part List -5713.6. Electrical Replacement Parts List-59RadioFans.CN 收音机爱 好者资料库31Safety Precautions1.1.General Guidelines1. IMPORTANT SAFETY NOTICEThere are special components used in this equipment which are important for safety. These parts are marked by in theSchematic Diagrams, Circuit B
12、oard Layout, Exploded Views and Replacement Parts List. It is essential that these critical partsshould be replaced with manufacturers specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modifythe original design without permission of manufacturer.2. An Isolation Transforme
13、r should always be used during the servicing of AC Adaptor whose chassis is not isolated from the ACpower line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personalinjury from electrical shocks. It will also protect AC Adaptor from being dam
14、aged by accidental shorting that may occur duringservicing.3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated ordamaged by the short circuit.4. After servicing, see to it that all the protective devices such as insulation bar
15、riers, insulation papers shields are properlyinstalled.5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.(This “Safety Precaution” is applied only in U.S.A.)1. Before servicing, unplug the power cord to prevent an electric shock
16、.2. When replacing parts, use only manufacturers recommended components for safety.3. Check the condition of the power cord. Replace if wear or damage is evident.4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.5. Before returning the servic
17、ed equipment to the customer, be sure to make the following insulation resistance test to preventthe customer from being exposed to a shock hazard.1.1.1.Leakage Current Cold Check1. Unplug the AC cord and connect a jumper between the two prongs on the plug.2. Measure the resistance value, with an oh
18、mmeter, between the jumpered AC plug and each exposed metallic cabinet part onthe equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to thechassis, the reading should be between 1M and 5.2M.When the exposed metal does not have a return pat
19、h to the chassis, the reading must be 1.1.2.Leakage Current Hot Check1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.2. Connect a 1.5k, 10 watts resistor, in parallel with a 0.15F capacitors, between each exposed metallic part on the set and agood
20、earth ground such as a water pipe, as shown in Figure 1-1.3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.4. Check each exposed metallic part, and measure the voltage at each point.5. Reverse the AC plug in the AC outlet and repeat each o
21、f the above measurements.6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent)may be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of thelimits specified, there is a pos
22、sibility of a shock hazard, and the equipment should be repaired and rechecked before it isreturned to the customer.Figure 1-141.2.Before Repair and AdjustmentDisconnect Power Supply AC to discharge AC capacitor in SMPS P.C.B. and AC Inlet P.C.B. through a 10 , 10 W resistor toground.1.2.1.SMPS P.C.
23、B.Figure 1-2Caution:DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.After repairs are completed, restore power gradually using a variac to avoid overcurrent. Current consumption at AC 220V - 240V, should be 50/60 Hz during power on (In
24、Standby mode) should be 0.30W. (E) Current consumption at AC 120V, 60 Hz during power on (In Standby mode) should be 0.30W. (PP)51.3.Protection CircuitryThe protection circuitry may have operated if either of the following conditions are noticed: No sound is heard when the power is turned on. Sound
25、stops during a performance.The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.If this occurs, follow