Mackie-ART300A-as-sm 维修电路原理图.pdf
《Mackie-ART300A-as-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Mackie-ART300A-as-sm 维修电路原理图.pdf(22页珍藏版)》请在收音机爱好者资料库上搜索。
1、ART300AActive LoudspeakerService Manual2002 MACKIE DESIGNS, INC.RadioFans.CN 收音机爱 好者资料库2ART300A Service Manual SERVICE ON THIS EQUIPMENT IS TO BE PERFORMED BY EXPERIENCED REPAIR TECHNICIANS ONLYRadioFans.CN 收音机爱 好者资料库3ART300A Service ManualCONTENTSSafety Instructions.2Introduction.4Active Speaker Sa
2、fety Test.5Overview.7Rear Panel .8Specifi cations.9Parts .10 Final Assembly.10 Amplifer Assembly.11 Amplifi er PCB Assembly.12 Input Board Assembly and PCB.14 RCF Parts Differences.15Main Circuit Board.16 Schematics Crossover .16 High Frequency Amplifi er.17 Low Frequency Amplifi er.18 Power Supply.
3、19 PCB Layout.20Input Board.21 Schematic.21 PCB Layout.224ART300A Service ManualIntroductionAbout this ManualThis manual contains the basic repair information for the ART series loudspeakers. For each model, the following information is supplied: Safety information Overview Rear panel view and featu
4、res Specifi cations and test details Parts list, containing a master parts list and sub-assembly parts Parts list differences between RCF and Mackie Industrial ART speakers Schematics PCB layout drawingIt is essential that you have a copy of the users manual as this contains the complete operating i
5、nstructions. Service Technical AssistanceMackie Designs, Service Technical Assistance, is available 8AM - 5PM PST, Monday through Friday for Authorized Mackie Service Centers, at 1-800-258-6883. Feel free to call with any questions and speak with a carefully-calibrated technician. If one is not avai
6、lable, leave a detailed message and a qualifi ed Mackoid will return your call asap.DisclaimerThe information contained in this manual is proprietary to Mackie Designs, Inc. The entire manual is protected under copyright and may not be reproduced by any means without express written permission from
7、Mackie Designs, Inc. SERVICE ON THIS EQUIPMENT IS TO BE PERFORMED BY EXPERIENCED REPAIR TECHNICIANS ONLY16220 Wood-Red Road NE, Woodinville, WA 98072 USATEL 888.337.7404, FAX 425.487.4337, UK +44.1268.571.212, FAX +44.1268.570.809 +industrialrcf-ITALY +39.0522.354.111, FAX +39.0522.926.208 +industri
8、alrcf.itFRANCE +33.3.8546.9160, FAX +33.3.8546.9161 +mercialwanadoo.frGERMANY +49.2572.96042.0, FAX +49.2572.96042.10 +industrialmackie.de5ART300A Service ManualYou must perform the following leakage test before returning any active speakers to your customer. Take every safety precaution to protect
9、yourself while doing this test. 1. Make a small loading RC circuit as shown in the diagram below, and connect the AC volt meter between the AC power source ground and any exposed metal on the unit under test.2. Connect the unit under test to an AC power source using a ground-lift adaptor, leaving th
10、e units safety ground fl oating. Turn the unit on.3. The meter reading should be less than 750mVAC (note: this is equivalent to 0.5mA of leakage current).4. Flip the plug over in the receptical so the hot and neutral are swapped. Verify that the reading is still less then 750mVAC. 5. If either readi
11、ng is greater than 750mVAC, then you must investigate and repair the speaker before returning it to your customer.Active speaker safety test6ART300A Service ManualSafety First!Before connecting and using the equipment, please read the Quick-Start Guide carefully and keep it for future reference.Warn
12、ingThis equipment has been designed to be installed by qualifi ed professionals only! There are many factors to be considered when installing professional sound reinforcement systems, including mechanical and electrical considerations, as well as acoustic coverage and performance. Mackie Industrial
13、strongly recommends that this equipment be installed only by a professional sound installer or contractor.1. Never install, connect, or disconnect the unit with the power supply on.2. Before powering up the speaker, make sure the voltage select switch corresponds to the AC Voltage supply.3. Make sur
14、e the safety ground on the power cord is properly grounded.4. To prevent the risk of electric shock, never open the unit. There are no user serviceable parts inside.5. To ensure normal cooling of the amplifi er, make sure the unit is well ventilated. Avoid exposure to direct sunlight or proximity to
15、 any heat source, dust, or dampness.InstallationA 1-3/8 (35mm) socket is provided in the bottom of the cabinet for mounting the loudspeaker on a speaker stand. The speaker can be suspended with approved rigging hardware. Always use at least two M10 threaded inserts located on opposite sides of the e
16、nclosure. The speaker must be positioned so that the weight of the enclosure is equally distributed over the two inserts.WarningNever attempt to suspend the ART Series loudspeakers by their handles. Consult a professional rigger or structural engineer prior to suspending loudspeakers from a structur
17、e not intended for that use. Always know the working load limit of the structure supporting the loudspeaker array. Always make sure that the rigging hardware minimum rating is at least fi ve times the actual load.7ART300A Service ManualOverviewThe ART300A is a full-range two-way professional active
18、speaker system that combines high power and wide bandwidth in a light-weight enclosure for fi xed-installation systems. The 12 low-frequency transducer, in combination with a 1 compression driver coupled to an integral 90 x 70 constant directivity polynomial horn, form an extremely powerful package
19、for any small to medium-sized sound reinforcement application.It features a balanced XLR input with a Mic/Line switch and a paralleled balanced XLR output for cascading multiple speakers. Rear panel controls also include Music and Voice equalization switches, a rotary volume control, and an input li
20、miter.The two built-in power amplifi ers provide 300W for the LF driver and 60W for the HF driver. The enclosure is constructed of high-strength polypropylene, with M10 threaded inserts on all four sides for rigging, and an integral locking 1-3/8 socket in the bottom for mounting on a standard speak
21、er stand.8ART300A Service ManualRear Panel1. INPUT is a balanced XLR input jack that accepts mic-level or line-level signals.2. OUTPUT is a balanced XLR output jack in parallel with the INPUT jack, allowing the signal to “loop through” for daisy-chaining speakers together.3. LINE/MIC switch for mic-
22、level or line-level signals at the INPUT.4. VOICE equalization switch ON provides a gentle boost at 3kHz and 6kHz.5. MUSIC equalization switch ON provides a low-frequency and high-frequency boost.6. LIMITER indicator illuminates when the limit-ing protection circuits are activated.7. OPERATE indicat
23、or illuminates when the POWER switch is turned on.8. VOLUME control adjusts the input-stage gain.9. POWER switch turns the AC power on and off.10. AC OUTLET for connecting AC power to an additional Mackie Industrial active speaker system.11. Grounding Terminal provides an additional safety grounding
24、 point.12. IEC AC Socket. Connect the detachable power cord to the socket. The protection fuse is also contained in the AC socket.CAUTION: Replace fuse only with the same type as indicated on the rear panel.ConnectionsThe XLR connectors use the following AES standard: Pin 1 = Ground (Shield) Pin 2 =
25、 Hot (+) Pin 3 = Cold ()12453810912 11769ART300A Service ManualSpecifi cationsSystem:Freq. Range (10 dB): 55Hz-19kHzFreq. Response (3 dB): 75Hz-16kHzHorz. Coverage Angle (6 dB): 90, averaged 1kHz-10kHzVert. Coverage Angle (6 dB): 70, averaged 1kHz-10kHzDirectivity Factor Q (DI): 10.0 (10.0), average